A Test Study on the Static/Dynamic Response of PC Structures According to the Connection Method and Damage Degree of PC Concrete Structures for Rapid Application of PC Concrete Construction Around Railway Stations (철도정거장 주변 PC 콘크리트 급속 시공 적용을 위한 PC 콘크리트 구조물 연결 방법 및 손상 정도에 따른 PC 구조물 정적/동적 응답에 대한 실험적 연구)

  • Park, Chang-Jin;Jeong, Han-Jung;Park, Yong-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.53-60
    • /
    • 2020
  • In this study, smart precast-in-place concrete, such as continuity with Precast any technology that can be the Application of Building Structures and railway stations, civil structures. After the same way in the field installation design based on the criteria railways and derived the right section, through the Static and Dynamic Response Analysis. Dynamic sensor and the triaxial acceleration measured by attaching the sensor acceleration response according to the extent of the damage of Precast Panel Structures and mode of Precast Structures, by comparing the data. Data for the stability and improvement of the uncertainty in along a railroad and Future of Precast Panel Structures of time to replace. This is to use this data as basic data on damage prediction.

Mediating Effects of Self-Respect and Cognitive Needs on the Relationship between Adolescents' Media Utilization and Critical Media Understanding (청소년의 미디어 활용 능력과 비판적 미디어 이해 능력의 관계에서 자아존중감과 인지욕구의 매개효과)

  • Kim, Dasol
    • Korean Educational Research Journal
    • /
    • v.43 no.1
    • /
    • pp.29-57
    • /
    • 2022
  • This study was conducted to determine the effects of adolescents' media literacy, self-esteem, and cognitive related to on critical media understanding ability using data from the Korea Media Panel Survey 2020. As a result of the study, PC literacy and smart device literacy influenced adolescents' critical media literacy. The mediating effect of cognitive needs between Internet literacy and critical media understanding ability using PCs and smart devices was significant, and the mediating effect of self-esteem between email literacy using PCs and smart devices and critical media understanding ability was significant. Therefore, to improve adolescents' critical media understanding ability, it is necessary to educate them to use PCs and smart devices as tools for interaction. To this end, it is desirable for information and technology subjects to focus on media literacy to increase cognitive needs, and for other subjects, cooperative learning using media is desirable.

An Experimental Study on the Sound Insulation Characteristics of Heavyweight Walls (중량벽체의 차음특성에 관한 실험적 연구)

  • 김선우;이태강;송민정
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1078-1085
    • /
    • 1998
  • This study is carried out to investigate the characteristics of sound insulation performances for masonry walls. PC walls and ALC walls. For these purposes. 17 types of masonry walls were selected and tested in accordance with KS F 2808 at reverberation room The sound insulation performance of 8" cement block walls are graded with D-45 ∼ D-55 which are to be evaluated very favorable grade. 4" cement block walls are D-30 ∼ D-40. 1 B cement brick walls are D-40∼D-50 favorable grade. 0.5 B brick walls are D-30∼D-45. 150 mm PC wall is D-50. and ALC walls(150 mm, 200 mm) are D-30∼D-45.

  • PDF

Physicochemical Properties and Sensory Evaluation for the Heat Level (Hot Taste) of Korean Red Pepper Powder

  • Ku, Kyung-Hyung;Lee, Kyung-A;Park, Jae-Bok
    • Preventive Nutrition and Food Science
    • /
    • v.17 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • This study investigated the heat level rating of several varieties of Korean red peppers. The chemical constitution of Korean red pepper samples were as follows: 0.54~290.15 mg% capsaicinoids, 79.22~139.09 ASTA value, and 16.76~29.92% free sugar content. The heat level of the Korean red pepper samples was evaluated by trained panelists and the correlation coefficient and F value (0.001%) of the panelist’s results were determined to be significant. In the principle component analysis (PCA), PC1 (capsaicinoids) and PC2 (free sugar) were shown to represent 31.98% and 25.77% of the total variance, respectively. The results of panelists trained for red pepper heat rating were evaluated using analysis of variance and correlation analysis. The trained panelists showed a high F value (p=0.05) and high correlation coefficient. A high correlation efficient of 0.84~0.93 for the test samples with a 40 Scoville heat unit (32,000 SHU red pepper powder) was reported in the sensory evaluation of the Korean red pepper heat level by a trained panel. However, the panel showed a low correlation efficiency of 0.70 $R^2$ when the 60 SHU test samples were included in the analysis.

Wall Charge Distribution In the Address Period of AC Plasma Display Panel (AC PDP의 addressing 기간중의 벽전하 분포에 관한 연구)

  • Lee, Ki-Bum;Kim, Dong-Hyun;Kang, Dong-Sik;Park, Chung-Hoo;Cho, Chung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1830-1833
    • /
    • 2000
  • The relationships between driving voltage and the wall charge distribution in the address period of surface discharge type AC Plasma Display Panel have been investigated. The quantity of wall charge on each electrode are detected simultaneously from the electrode current after applying only one addressing discharge pulse. The wall charge Qy on the scan electrode Y is nearly the sum of Qx on the address electrode X and Qz on the sustain electrode 2. The Qy increased with the driving voltage regardless of the kind of electrode, whereas the address time Td decreased, Qz and Qy are increased considerably with the blocking voltage Vz, whereas Qx is decreased. The increase rate of Qx, Qy and Qz for increase in Vz was $-13{\times}10^{-2}$(pc/Vz), and $60{\times}10^{-2}$(pc/Vz) and $70{\times}10^{-2}$(pc/Vz), respectively.

  • PDF

Shear Strength of Vertical Joints in Precast Concrete Panel with Shear Key (전단키를 갖는 프리캐스트 콘크리트 패널 수직접합부의 전단강도)

  • Lee, Sang-Sup;Park, Keum-Sung;Bae, Kyu-Woong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.151-158
    • /
    • 2019
  • A concrete core is used widely as lateral stability systems in high-rise modular buildings. As an alternative to traditional cast in-situ core, the precast concrete(PC) method can accelerate the construction of reinforced concrete cores. A core composed of precast elements differs from a in-situ core in having connections between the precast elements. The typical vertical connection between PC panels is consisted of shear keys, loop bars, lacer bars and grout. In this study, the effect of vertical connection components on shear strength is investigated experimentally. The test results show that the contribution to the shear strength is greater in order of grout strength, shear keys, lacer bars and loop bars. In addition, the numerical models to estimate the shear strength according to two crack patterns in the vertical joint of the PC panels are derived. The feasibility of the numerical models is evaluated by comparing the estimated shear strength and the test results.

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Effects of Reinforcing Method Influnced to the Shear Strength of Vertical and Horizontal Joints in Precast Concrete Large Panel Structures -Focused on the Vertical Joints and Slab-Slab Type Horizontal Joints- (대형판조립식 구조 수직.수평접합부의 전단강도에 미치는 보강방법의 영향-수직접합부 및 슬래브-슬래브 수평접합부를 중심으로-)

  • Chung, Lan;Park, Hyun-Soo;Cho, Seung-Ho
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.4
    • /
    • pp.171-179
    • /
    • 1996
  • A proposal of the basic fbrm on the design of joint parts that can increase the shear strength by the useful joint shapes of each member is intended. The vertical joint parameters are the number of' shear key and a variety of' reinfbrcement details and the horizontal joint paramctcrs arc t,hc number of shear key and the direction of' shear f'orcc. 10 PC panel vortical joint arid 12 PC panel horizontal joint specimens were tested to investigate the effects of these parameters. Test results show that : 1. The ductility of the test specimen that has the horizontal reinforcing steels is larger than that does not have. 2. The maximum resisting force of round bar specimen is similar to that of strand wire specimen under the condition of fixed horizontal displacement.

Recent Progress in WV Films - OCB-WV -

  • Mori, Hiroyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1501-1504
    • /
    • 2006
  • The WV film successfully enlarged the field of view of the TN mode and made TN popular for larger size applications such as PC monitors. The hybrid alignment of the PDM (polymerized discotic material) layer is also suited for the OCB mode, which is promising as a nextgeneration LCD-TV because of fast panel response and a wide viewing angle. This paper describes recent technological progress in WV films, especially for OCB.

  • PDF

Aging Measurement and Compensation for OLED Panel (OLED 패널의 노화 측정 및 보상)

  • Jeong, Kyung-Joong;Jeong, Hong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1009-1010
    • /
    • 2008
  • This paper presents a real-time aging measurement and feasible compensation system for the prolonged lifetime of OLED panel. The proposed system is composed of four parts, a PC with a man-machine interface, a measurement block, an adaptive amplifier block, and a compensation block. We apply a tree algorithm for less complexity and convenience of measurement on the degree of aging. An adaptive multi-stage differential amplifier is also implemented to deal with a various range of input voltages at the same spot.

  • PDF