• Title/Summary/Keyword: PBU

Search Result 35, Processing Time 0.017 seconds

Effects of pressure biofeedback application location for subjects with lumbar instability on pelvic rotation and hip joint abductor muscle activity during the Clam exercise.

  • Choi, Yonggil;Lee, Sangyeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.90-97
    • /
    • 2021
  • Objective: The purpose of this study was to find out how the back instability during clam exercise (CE) causes changes in pelvic rotation and hip joint abductor muscle activity, and to find out the effects with different methods of application of pressure biofeedback. Design: Comparative study using repeated measures. Methods: Each subjects performed the clam exercise (CE) without pressure biofeedback, the clam exercise with pressure biofeedback applied to the back (CE-PBU to back), and the clam exercise with pressure biofeedback applied to the side (CE-PBU to side). The amount of pelvic rotation was measured using myomotion. And the muscle activity of the muscle gluteus medius and the tensor fasciae latae was measured using EMG device. One-way repeated measures ANOVA followed by the Bonferroni post test were used to compare the EMG activity in each muscle and pelvic rotation angle during the CE, CE-PBU to back, CE-PBU to side. Results: The amounts of pelvic rotation was the lowest in CE-PBU to back (p< 0.05) and the ratio of muscle activity of the muscle gluteus / tensor fasciae latae was the highest in CE-PBU to back (p< 0.05). Conclusions: It is thought that, in order to stabilize the waist-pelvis and increase hip joint muscle strength in subjects with back instability, applying clam exercise with pressure biofeedback applied to the lower back is effective in improving waist-pelvic movements and selectively strengthening the muscle gluteus medius.

The Correlation of the Pressure of Biofeedback Unit and Lumbopelvic Motion During Straight Leg Raising in Healthy Subjects (정상인에서 수동적인 뻗은다리올림 시 생체되먹임 장치의 압력과 허리골반 움직임의 상관관계)

  • Jung, Do-young
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.12-18
    • /
    • 2018
  • Background: Passive straight leg raising (PSLR) is the common clinical test to measure of hamstring muscle length. Hip flexion angle contributes to change the lumbopelvic rotation during PSLR. Pressure biofeedback unit (PBU) is commonly used to detect lumbopelvic movement during lower limb movements. Thus, there may be the relationship between pressure of PBU and lumbopelvic motion during PSLR. Objects: The objective of this study was to determine the relationship between pressure of PBU and lumbopelvic motion during PSLR. Methods: Thirty two subjects participated in this study. A three-dimensional motion analysis system were used to measure the lumbopelvic angle during PSLR, while recording the pressure of PBU according to angle of PSLR by 10 degree increments. Pearson product moment correlations and linear regression analysis were used to describe the relationship between variables. Results: The results showed that there was a significant relationship between the lumbopelvic and angle of PSLR (Pearson's r=.83, p<.05), between the pressure of PBU and angle of PSLR (Pearson's r=.75, p<.05), and between lumbopelvic motion and pressure of PUB (Pearson's r=.83, p<.05). Linear regression equation using lumbopevic angle as an independent factor was as follows: Pressure of PBU = 47.35 + (2.55 ${\times}$ angle of lumbopelvic motion) ($R^2=.69$, p<.05). Conclusion: Results of the present study indicate that pressure of PBU can be used to indirectly detect the amounts of lumbobevic motion during muscle length test or stretching of hamstring.

Molecular Structure of PCP Pincer Complexes: Poisoning Catalyst on the Dehydrogenation of Alkanes (알칸의 탈수소화반응에서의 촉매독 화합물의 분자구조)

  • Lee Ji Hyun;Chun Sang Jin;Kwon Ki Hyeok;Lee Do Weon
    • Korean Journal of Crystallography
    • /
    • v.16 no.1
    • /
    • pp.43-53
    • /
    • 2005
  • The dihydrido P-C-P pincer complex, $IrH_2{C_6H_3-2,6-(CH_2PBu_2^t)_2}$ (1), was successfully prepared from the reaction of the hydrochloride complex, $IrClH (C_6H_3-2,6-(CH_2PBu_2^t)_2}$, and super acid $(LiBEt_3H)$ under 1 atm of hydrogen in pentane solution at room temperature and followed by Heating at $130^{\circ}C$ in vacuo. Jensen recently found that the dihydrido P-C-P pincer complex 1 is a highly active homogeneous catalyst for the transfer dehydrogenation of alkanes with unusual longterm stability at temperatures as high as $200^{\circ}C$. The treatment of dihydrido complex 1 with nitrogen, water, carbon dioxide, and carbon monoxide in presence of tert-butylethylene (the) at room temperature in an appropriate solution gave the dinitrogen complex, $[Ir{C-6H_3-2,6-(CH_2PBu_2^t)_2}]_2({\mu}-N_2)$ (2), the hydrido hydroxyl complex, $IrH(OH){C_6H_3-2,6-(CH_2PBu_2^t)_2}$ (3), the carbon dioxide complex, $Ir({\eta}^2-CO_2) {C_6H_3-2,6-(CH_2PBu_2^t)_2}$ (including the bicarbonate complex, $IrH({\kappa}^2-O_2COH){C_6H_3-2,6-(CH_2PBu_2^t)_2}\;(4))$, and the carbonyl complex, $Ir(CO) {C_6H_3-2,6-(CH_2PBu_2^t)_2}\;(5)$ (including the carboxyl complex, $IrH(C(O)OH) {C_6H_3-2,6-(CH_2PBu_2^t)_2}\;(6))$, in good yield, respectively. These P-C-P iridium complexes were isolated and characterized by $^1H,\;^{13}C,\;^{31}P\; NMR$, and IR spectroscopy. In addition, the complexes (1-6) were characterized by a single crystal X-ray crystallography. These complexes account for these small molecules' inhibition of dehydrogenation of alkanes catalyzed by the dihydrido complex 1.

Shopping Satisfaction in Mobile Distribution Channels: Focusing on Prudent Shopping Behavior

  • Hyeonmi YOO;Se Hun LIM
    • Journal of Distribution Science
    • /
    • v.22 no.8
    • /
    • pp.99-107
    • /
    • 2024
  • Purpose: The aim of this study is to explore the psychological characteristics of users in mobile distribution channels (MDC) during mobile shopping. Research design, data and methodology: A conceptual framework based on shopping satisfaction theory was developed, leading to the proposal of a research model to examine the relationships between emotional control (EC), emotional practice (EP), prudential buying tendency (PBT), prudential buying urge (PBU), prudential buying behavior (PBB), and mobile shopping satisfaction (MSS) in MDC. To validate the research model, 125 survey responses were collected from mobile shoppers, and the relationships among EC, EP, PBT, PBU, PBB, and MSS were analyzed using the PLS structural equation model. Results: The empirical analysis revealed that EC did not have a significant impact on PBT, while EP had a significant effect on PBT. Moreover, PBT was found to influence both PBU and PBB, with PBU significantly affecting PBB. Finally, the study found that PBB significantly influences MSS. Conclusions: This study elucidates the relationships among EC, EP, PBT, PBU, PBB, and MSS, providing valuable insights for enhancing consumer shopping satisfaction in MDC. Practically, the study suggests various strategies for personalized and differentiated mobile customer management. Theoretically, it contributes to the field by stimulating further research on prudent purchasing behavior in mobile commerce.

Comparison of the Cross-Sectional Area of Longus Colli and Muscle Activity of Sternocleidomastoid in Subjects With Forward Head Posture on the Two Craniocervical Flexion Methods

  • Son, Min-chan;Hwang, Ui-jae;Jung, Sung-hoon;Ahn, Sun-hee;Kim, Hyun-a;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.25 no.2
    • /
    • pp.62-70
    • /
    • 2018
  • Background: The craniocervical flexion (CCF) exercise is one of the effective exercise in correcting forward head posture (FHP). However, some people with FHP achieve CCF with compensatory movements, for example, low cervical flexion using superficial neck flexors such as the sternocleidomastoid (SCM) muscle. No study has yet investigated whether a dual­pres ure biofeedback unit (D-PBU) method to prevent low cervical flexion would be helpful in performing pure CCF movement. Objects: The purpose of this study was to compare the effects of the CCF using D-PBU method and the traditional CCF method on the cross-sectional area (CSA) of the longus colli muscle (LCM) and the activity of SCM muscle in subjects with FHP. Methods: Twenty­four FHP subjects (male: 16, female: 8) were recruited for this study. All subjects performed CCF using two different methods: the traditional CCF method and the CCF using D-PBU method. The CSA of the LCM was measured via ultrasound, and surface electromyography was used to measure SCM muscle activity. Results: The change in CSA of the LCM was significantly larger during the CCF using D-PBU method ($1.28{\pm}.09$) compared with the traditional CCF method ($1.19{\pm}.08$) (p<.05). The SCM muscle activity using the CCF using D-PBU method ($2.01{\pm}1.97$ %MVIC) was significantly lower than when using the traditional CCF method ($2.79{\pm}2.32$ %MVIC) (p<.05). Conclusion: The CCF using D-PBU method can be recommended for increasing LCM activation and decreasing SCM muscle activity during CCF movement in subjects with FHP.

Polymeric Membrane and Solid Contact Electrodes Based on Schiff Base Complexes of Co(III) for Potentiometric Determination of Perchlorate Ions

  • Soleymanpour, Ahmad;Hanifi, Abdolghafoor;Kyanfar, Ali Hossein
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1774-1780
    • /
    • 2008
  • New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)$(PBu_3)_2$]$ClO_4$, [Co($Me_2$Salen)$(PBu_3)_2$]$ClO_4$, [Co(Salen)$(PBu_3)H_2O$]$ClO_4$; as anion carriers for potentiometric determination of $ClO_4\;^-$were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)$(PBu_3)_2$]$ClO_4$ showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to $ClO_4\;^-$ ions over a wide concentration range with low detection limits ($1.0 {\times} 10^{-6}\;mol\;L^{-1}$ for PME and $9.0 {\times} 10^{-7}\;mol\;L^{-1}$ for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward $ClO_4\;^-$ relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.

Efficient IP Mobility Management Scheme in Vehicular Networks (차량 통신망에서 성능 효율적인 IP 이동성 관리 기법)

  • Jeon, Jae-Sung;Hong, Kun-Ho;Lee, Su-Kyoung
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.6
    • /
    • pp.698-701
    • /
    • 2010
  • Recently, Vehicular Networks is being developed to provide variety of services such as email, ftp, and video streaming services. As IP mobility technology, Proxy Mobile IP is developed to provide these services for a VANET user. By adopting Proxy Mobile IPv6 (PMIPv6), Vehicular Networks can support IP mobility, but it may cause a proxy binding update (PBU) message when a vehicle moves from one MAG to another. In addition, if the density of vehicles on the road is high, significant PBU messages are generated. In this paper, we propose bulk PBU message to reduce signaling overhead by those PBU messages when a bunch of vehicles move from one MAG to another. When the vehicles move from one MAG to another, it generates only one bulk PBU message to update those vehicle's location. Through numerical and simulation results, we show that our proposed bulk registration reduces signaling overhead when the density of vehicles and the speed of them are high.

A Preliminary Study of the Effect of Kegel Exercise Using a Pressure Biofeedback Unit on Maximum Voluntary Ventilation and Abdominal Muscle Thickness (압력 생체되먹임 기구를 이용한 케겔 운동이 최대 수의적 환기량과 배 근육 두께에 미치는 사전 연구)

  • Lee, Kyung-Soon;Park, Kang-Hui;Park, Han-Kyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose : Kegel exercises reported that it is effective in managing stress-related or complex urinary incontinence through contraction and relaxation of the pelvic floor muscles. In many previous studies, it was confirmed that Kegel exercise is involved in respiration as well as urinary system diseases. However, there is a lack of research on the effect of pelvic setting when performing Kegel exercises. Therefore, this study was conducted to investigate the effect on maximum voluntary ventilation (MVV) and abdominal muscle thickness through Kegel exercise after lumbar-pelvic motor control using pressure biofeedback unit (PBU). Methods : The subjects of this study were 10 healthy female students in their 20s. Subjects measured MVV with a spirometer. In hooklying, external oblique, internal oblique, and transverse abdominis of the dominant hand were measured using ultrasound. The measured value was an average of three times. After one week of intervention, measurements were made in the same manner. Before Kegel exercise, pelvic setting training was performed using PBU. In hooklying, PBU was placed in the waist and set to 40 mmHg, and it was adjusted to 60 mmHg through pelvic muscle contraction. For Kegel exercise, the pelvis was first set using PBU, and then the pelvic floor muscles were contracted for 8 seconds and relaxed for 8 seconds, 10 times, 1 set, and 3 sets. Results : In MVV, a significant difference was confirmed after exercise than before exercise (p<.05). There was also a significant difference in abdominal muscle thickness before and after exercise (p<.05). Conclusion : Based on the results of this study, Kegel exercise using PBU had an effect on MVV and abdominal muscle thickness. However, since this study was conducted without a control group as a preliminary study, additional research should be conducted to supplement this.

Chemical Reactions in Solid State Complexes of 1,2-Polybutadiene and Palladium Chloride : High Temperature Infrared Study

  • Lee, Joon Y.;Laurence A. Belfiore
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.9
    • /
    • pp.826-830
    • /
    • 1996
  • Fourier transform infrared (FTIR) temperature studies were performed to examine the microstructural changes that occur in annealing process of the thin films of 1,2-polybutadiene (1,2-PBu)/palladium chloride (PdCl2) complex. The disappearance of the infrared absorption intensities at 1640, 1418, 994 and 910 cm-1 signifies the consumption of 1,2-vinyl groups of 1,2-PBu. The progressive loss of unsaturation and production of methyl groups as a function of temperature were identified by the enhanced infrared absorption intensities at 1447 and 1375 cm-1. The loss of pendent carbon-carbon double bond is considered to involve both palladium-catalyzed addition reaction and thermally induced cyclization.

Reliability of the Active Knee Extension Test With a Pressure Biofeedback Unit

  • Kim, Chang-ho;Gwak, Gyeong-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.40-46
    • /
    • 2017
  • Background: The active knee extension (AKE) test commonly used to assess the flexibility of the hamstring muscles. Many researchers have tested the reliability of the AKE test; however, no published studies have examined the intrarater and interrater reliability of the AKE test using a PBU. Objects: The purpose of this study was to determine the intrarater and interrater reliability of the AKE test performed with a pressure biofeedback unit (PBU) on healthy subjects. Methods: Sixteen healthy male participants volunteered and gave informed consent to participate in this study. Two raters conducted AKE tests independently with a PBU. Each knee was measured twice, and the AKE testing was repeated one week after the first round of testing. Results: The interrater reliability's intraclass correlation coefficients ($ICC_{2,1}$) were .887~.986 for the right knees and .915~.988 for the left knees. In addition, the intrarater (test-retest) reliability ($ICC_{3,1}$) values ranged between .820~.915 and .820~.884 for Raters 1 and 2, respectively. The values for the standard error of mesurement were low for all tests ($.81{\sim}2.97^{\circ}$); the calculated minimum detectable change was $2.24{\sim}8.21^{\circ}$. Conclusion: These findings suggest that the AKE test performed with a PBU had excellent interrater and intrarater reliability for assessing hamstring flexibility in healthy young males.