• Title/Summary/Keyword: PACS (Radiology)

Search Result 117, Processing Time 0.025 seconds

Time-Phased Implementation of a Large-Scale PACS at Samsung Medical Center

  • 노덕우;최형식;임재훈;김원기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.26-27
    • /
    • 1994
  • The first step implementation of a hospital-wide Picture Archiving Communications System (PACS) at a newly built hospital Samsung Medical Center (SMC), is described. Current clinical operation encompasses the fiber optics delivery of direct-interfaced magnetic resonance imager (LRI), X-ray computed tomography (CT). digital subtraction angiography (DSA) and computed radiography (CR) digital images via high performance file server to the departments of radiology, neurosurgery, orthopedics surgery, neurology, emergency room and the surgical intensive care unit.

  • PDF

외부자료 입력방법에 따른 업무의 효율성 비교평가 (Evaluation the external data import methods assess the effectiveness of the work)

  • 신승희;이승진;정재은;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.39-45
    • /
    • 2013
  • PACS Import external image of the thread of the tasks and duties of hospital revenue and business efficiency falls over time. 500 beds or more medical imaging import work outside of the hospital, most hospitals use a PC, KIOSK, and was used in 15 hospitals where, CD Autoloader where use was the only one. Working hours compared to CD and DVD media to test the results of the Import target PC, KIOSK, CD Autoloader Import spent less time in the order, and also the greater capacity of CD Autoloader four times the PC, KIOSK 2 times Import could be implemented quickly. In addition, the waiting time of the patients was measured using the PC's time to Import, 2011 14.5 minutes and the average patient waiting time, KIOSK and later use CD Autoloader 2012 average patient wait time of 8.25 minutes, 43% of the existing average waiting time was 5.25 minutes to reduce. However, KIOSK case of a patient in a way that directly Import latency time was soon. Import of three ways: in terms of efficiency and excellent CD Autoloader way, the patient waiting time in terms of ease of use and KIOSK was excellent. In addition, with the introduction of CD Autoloader with KIOSK Joint of the items waiting time of patients and patient satisfaction rating is considered to be a major contribution.

  • PDF

PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구 (A Study on Reduction Effect of Processing Wastewater by Introduction of PACS)

  • 고신관;한동균;김욱동;강병삼;양한준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권2호
    • /
    • pp.167-175
    • /
    • 2007
  • 2001년부터 본격적으로 보급되기 시작한 PACS 도입은 영상의학과에서는 필름비용 절감, 인건비 절감, 현상액 사용량 절감, 관리업무 축소, 재 촬영 건수의 감소 등의 효과를 볼 수 있었고, 임상 의사들에게는 의료영상동시 활용, 임상정보의 증대, 진료 환자수의 증가, 의료영상 및 판독결과 활용성 증대 효과를 기대할 수 있는 것으로 알려져 있다. 환자들에게는 방사선 피폭선량 감소, 진료비 절감, 임상정보를 신속하게 알 수 있는 효과가 있다. 이에 본 저자들은 Full PACS를 도입한 서울 및 경기도의 10개 종합병원을 대상으로 하여 PACS로 인한 긍정적인 여러가지 효과 중 현상, 정착 폐수의 감소 추이를 알아보기 위하여 도입 1년 전과 도입 3년 후를 비교 분석하여 다음과 같은 결론을 얻었다. 1. 1개월 당 검사 건수는 7357.7건이 증가하였으나 필름 사용량은 90%가 감소하였다. 2. 현상액 월 평균 소모량은 3년 후 92%가 감소하였고, 정착액은 86%가 감소하였다. 3. 필름 1장 당월 평균 현상액 소모량은 3년 후 149%가 증가하였고, 정착액은 300%가 증가하였다. 4. 현상 폐수 발생량은 3년 후 월 평균 88%가 감소하였고, 정착 폐수는 87%가 감소하였다. 5. 3년 후 필름 1장 당월 평균 현상폐수 발생량은 377%, 정착폐수 발생량은 385%가 증가하였다.

  • PDF

비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구 (Study on image quality improvement using Non-Linear Look-Up Table)

  • 김선칠;이준일
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구 (A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography)

  • 최남길;성호진;전주섭;김윤현;성동욱
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.25-34
    • /
    • 2012
  • 본 연구는 진단용 X-선 촬영에서 부가필터 두께에 따라 피폭 선량 및 의료영상저장전송시스템에 저장된 영상을 비교 평가하여 환자에게 가장 적은 방사선 피폭을 주면서 진단에 적절한 영상을 얻을 수 있는 촬영 조건을 알아보고자 하였다. 그 결과 면적선량($mGy{\cdot}cm^2$)과 입사표면선량($mGy$)은 1 mmAl+0.2 mmCu의 부가필터에서 가장 낮은 피폭 선량값을, 그리고 0 mmAl (No Filter)에서 가장 높은 피폭 선량 값을 보였다. 그러나 의료영상저장전송시스템으로 전송된 영상을 수치 해석 소프트웨어(MATLAB)로 구현한 히스토그램 결과 영상의 질에는 크게 영향을 미치지 않았다. 따라서 진단용 X-선 촬영 장치를 이용한 영상의학적 검사에서 영상의 질에 영향을 미치지 않고 피폭선량을 경감할 수 있는 최적의 부가필터를 사용함으로서 환자의 피폭 선량을 예측하고 검사 조건을 조절하는 데 있어 유용하게 이용될 수 있을 것으로 판단되었다.

CDMA에 의한 의료영상의 PDA전송 (PDA Transmission of Medical Images by CDMA)

  • 이명호;임재동;안병주;이훈재;이상복
    • 한국방사선학회논문지
    • /
    • 제1권2호
    • /
    • pp.13-22
    • /
    • 2007
  • 본 논문은 유비쿼터스 의료를 위한 의료영상의 무선전송의 개발을 목적으로 한다. 컴퓨터 시스템의 발달로 인해 의료 장비와 의료 기록 체계에 대한 많은 변화가 일어났다. 그 중 병원내의 진료 및 의무기록을 자동화하고 관리하는 HIS(Hospital Information System) 시스템과 환자에게서 촬영된 영상에 대한 관리 체계인 PACS(Picture Archiving Communication System)은 대표적인 예라할 수 있다. 이러한 자동화된 진료 시스템은 병원 내에 있지 않을 경우 이용이 곤란하며, 응급상황이나 의사 부재시에 신속한 영상 판독이 요구되는 경우 이를 즉시 수행하기는 곤란하였다. 이러한 이동에 따른 단점을 보완하기 위하여 각 의사마다 지급된 PDA를 사용하여 병원내의 영상 획득 장치로부터 생성된 환자 영상을 원격에서 CDMA 망을 사용하여 검토할 수 있는 시스템을 구현하였다. 이를 위하여 의사 및 환자의 계정 관리와 환자 영상을 영상획득 장치로부터 수신 받아 각 의사별로 할당하도록 하는 서버 시스템을 구현 하였으며, PDA를 사용하여 서버에 접속하여 환자의 영상을 검토할 수 있도록 구현하였다. 개인별로 시스템 사용에 대한 인증을 위하여 PDA에서는 데이터베이스 RDA(Remote Data Access) 방식을 사용하여 서버 데이터베이스를 엑세스하였으며, 환자 영상을 서버로부터 다운로드 하기 위하여 FTP(File Transfer Protocol)를 사용하였다. 실험 결과 한 파일의 크기가 0.37Mbyte 인 832x488*24 영상 30매를 보낸다고 가정하였을 때 약 90초 정도의 시간이 걸렸으며 이는 긴급히 또는 원격에서 영상의 수신과 검토에 문제가 없음을 나타낸다.

  • PDF

스마트 케어 시스템에서의 3차원 전립선 암 가시화 도구 개발 (Develop 3D Prostate Cancer Visualization Tool in Smart Care System)

  • 안병욱;신승원;최문형;정승은;김광기
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.163-169
    • /
    • 2016
  • In Korea, prostate cancer accounted for generating growth rate second the following thyroid cancer, because of western dietary habits. Survival rate of prostate cancer after clinical behavior is changed depend on follow-up management. A telemedicine have been applied to replacement of medical specialist in rural area, and a quick reaction to emergency situation. Our study developed prostate 3-dimensional (3D) visualization program and designed prostate aftercare system architecture, called smart care, using a device that can access the Internet. Region of interest (ROI) in prostate was manually segmented by physicians and visualized to 3D objects and sent to PACS Server as DICOM images. So, medical personnel could confirm patients' data along with 3D images not only PACS system, but also portable device like a smart phone. As a result, we conducted the aftercare service to 98 patients and visualize 3D prostate images. 3D images had advantage to instinctively apprehend where lesion is and make patients to understand state of their disease easily. In the future, should conduct an aftercare service to more patients, and will obtain numerical index through follow-up study to an accurate analysis.

MIM 소프트웨어를 이용한 3-D PET/CT 영상의 방사선치료 평가를 위한 임상적용에 관한 연구 (Using MIM Software 3-D PET / CT imaging for the evaluation of radiation therapy on the clinical application of research)

  • 이상호
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.249-255
    • /
    • 2015
  • 본 연구는 PET/CT의 이미지 추가 정보를 통해 이미지 재형성과 합성기능을 바탕으로 TPS 임상 적용과 기초 자료 활용 및 지속적인 연구 개발을 위하여 True-D 기법과 MIM 소프트웨어를 접목하여 각각의 영상 간 합성 작업을 기반으로 이미지의 폭 넓은 활용으로 임상에서 판독에 소용되는 시간 및 비용을 줄이고 효율적 진단 및 방사선치료 시 종양 표적 결정에 유효한 도구로 사용하고자 함이며 정밀한 치료효과 판정에 활용하여 임상에서 판독에 소요되는 시간과 불필요한 추가 검사를 줄일 수 있을 것으로 기대하며 종양환자 판독 보고서 작성 및 PACS 등 타 소프트웨어와의 호환성 개발로 PET/CT 기기의 성능평가에 활용 될 것으로 기대한다.

RFID와 Worklist 중심의 OCS 프로그램 접목을 통한 환자유도시스템 개발과 환자만족도 조사 (Survey for Patient Satisfaction Rate & Patient Leading System Development through RFID and OCS Worklist Program Connection)

  • 지연상;동경래;김창복
    • 한국콘텐츠학회논문지
    • /
    • 제9권5호
    • /
    • pp.197-205
    • /
    • 2009
  • 컴퓨터가 도입된 이후 업무편리성이 증가한 반면 업무의 융통성이 줄어들어 업무의 일정 부분에서는 인간이 컴퓨터에 종속된 경향이 있다. 기존에는 영상의학과 접수에서 촬영완료에 이르기 까지 사람이 작업함으로써 많은 시간이 소요되고 환자 입장에서는 촬영순서 및 촬영 과정을 인지하기 어려운 단점이 있었다. 임상에서 RFID는 종합검진센터에서 환자의 위치추적을 목적으로 사용한바 있기 때문에 영상의학과에서 업무 효율성을 증가할 목적으로 RFID와 Workflow 중심의 OCS 시스템을 적용하여 업무 흐름을 개선하고자 하였다. 그래서 RFID를 접목시킨 Worklist 중심 OCS 프로그램을 개발한 결과 환자 만족도와 업무 흐름이 월등히 개선되는 효과를 거두었다. 이런 결과를 토대로 RFID 시스템은 추후 PACS등과 연계하여 Worklist에 접목 시킨다면 병원 업무에서 진정한 의미의 Ubiquitous를 구현하는 방안으로 유용한 시스템이라 여겨진다.

PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구 (The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment)

  • 정재호;김은수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.147-153
    • /
    • 2014
  • 디지털 Mammography영상에서 압축률에 따른 화질의 특성에 대해 정량적 평가와 정성적평가를 실시하였다. ACR Accreditation phantom을 대상으로 JPEG2000, JPEG 압축알고리즘을 적용하여 압축한 후 Detection Score를 측정하여 압축률에 상관없이 10점 인정기준을 충족하였다. 또한 실제미세병소 영상을 선정하여 압축을 실시하여 확대율에 따른 진단능의 변화를 측정하여 20:1 이상 압축 후 50% 이상 확대 시 진단능에 영향을 미칠 수 있음을 알 수 있었다. 또한, 정량적 평가방법인 PSNR, RMSE, MAE, SSIM등을 측정하여 압축률에 따른 원본영상과의 차이점은 비교적 허용 가능한 오차범위 내의 값이 측정되었다. 또한 MTF 측정을 통해 Full Field Digital Mammography 영상의 화질이 진단에 적합한 영상임을 알 수 있었다.