• Title/Summary/Keyword: PACS (Radiology)

Search Result 117, Processing Time 0.026 seconds

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

Effect of Head Positioning in Panoramic Radiography on the Vertical and Horizontal Magnification : Displacement along the Sagittal and Transverse Plane (파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향 : 전후방 및 좌우 이동)

  • Kim, Yong-Gun;Lee, Young-Kyun;An, Seo-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • The purpose of this study was to investigate how image magnification in dental panoramic radiography is influenced by object position. Five metal balls (4 mm in diameter, 2 for the anterior and 3 for the posterior region on the right side) were placed above alveolar crest of dry skull considering extraction socket and dental arch. Dry skull was radiographed using OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and displaced position along the sagittal and transverse plane at 3 mm, 6 mm, 9 mm, 12 mm and 15 mm using special mount which can control precise movement. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software (Infinitt Co., Ltd., Seoul, Korea). The mean horizontal magnification was 1.224-1.439 and mean vertical magnification was 1.286 - 1.345 at proper position. Vertical magnification resulted in less variation (1.245-1.418) than horizontal magnification (0.798-6.297) according to the sagittal and transverse displacements. Head positioning is important for linear measurement on panoramic radiography and inclusion of standard object (for instance, metal ball) is helpful to anticipate exact magnification of panoramic radiographs at various location.

Evaluation of Fibrosis in Liver Cirrhosis by Superparamagnetic Iron Oxide (SPIO)-Enhanced MR Imaging: Does the Radiological Non-Invasive Fibrosis Index Correlate with the Laboratory Non-Invasive Fibrosis Index? (Superparamagnetic Iron Oxide-Enhanced MRI를 이용한 간섬유화의 평가: 영상의학적 비침습적 간섬유화 지표가 AST/혈소판 비와 상관 관계가 있는가?)

  • Kim, Shin-Kee;Lee, Chang-Hee;Kim, Kyeong-Ah;Choi, Jae-Woong;Lee, Jong-Mee;Park, Cheol-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2008
  • Purpose : To evaluate the correlation between the radiological non-invasive hepatic fibrosis index (RNHFI), as determined by SPIO-enhanced MRI, and the laboratory non-invasive hepatic fibrosis index. Materials and Methods : Patients (99 total: 61 men and 38 women; mean age: 58 years) who underwent SPIO-enhanced MRI (1.5T) during 5 years included. These patients were subdivided into a liver cirrhosis group (LCG) and a non-liver cirrhosis group (non-LCG). Using PACS view, we measured the RNHFI (mean standard deviation of hepatic signal intensity (SD), noise-corrected coefficient of variation (CV)) of three ROIs in the liver parenchyma by SPIO-enhanced MRI. The laboratory non-invasive hepatic fibrosis index (AST-platelet ratio index (APRI)) of all patients was calculated from the laboratory data. We compared the RNHFI and APRI of LCG with those of non-LC group using Student's t-test. A bivariate correlation was performed to investigate the relationship between the RNHFI and APRI in the LCG. Results : For the LCG, mean values of SD and CV by SPIO-enhanced MRI were $10.3{\pm}3.7$ and $0.19{\pm}0.08$, respectively. For the non-LCG, mean values of SD and CV were $6.5{\pm}1.6$ and $0.08{\pm}0.05$, respectively. The mean APRI of the LCG and the non- LCG were $2.04{\pm}1.7$ and $0.32{\pm}0.32$, respectively. The RNHFI and APRI were significantly different between both groups (p<0.05). For the LCG, the bivariate correlation between SD and APRI revealed a statistically significant positive correlation (r=0.5, p<0.001). In both groups, there was no statistically significant correlation between CV and APRI. Conclusion: A measurement of SD can be a simple and useful method for the evaluation of hepatic fibrosis.

  • PDF

The Study of patient rotation angle to get the scapular true lateral image in scapular lateral projection (견갑골 측방향 촬영에서 견갑골 정측면상을 얻기 위한 환자의 회전각도에 관한 연구)

  • Park, Ki-Bong;Kang, In-Hyi;Choi, Nam-Kil;Jang, Young-Il;Jeon, Ju-Seob
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.203-209
    • /
    • 2005
  • Objective True lateral scapular image was very important to diagnosis the scapular fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapular true lateral in Korean. Subjects and Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine anteroposterior projection taken with $32^{\circ}$, $37^{\circ}$, $42^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlab of vertebral border and axillary border of scapular as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor. Results $32^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $37^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $42^{\circ}$trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. Conclusions There was no result of trunk rotation angle to radiograph the true scapular lateral image up to date. This studies were summarized as follows; Adaptation of $37^{\circ}$ trunk rotation was the best to show the true scapular lateral image in Korean. Our results were very useful to get the true scapular lateral images in clinic.

  • PDF

A Study of the New Positioning Guide Based on the Correlation between the Orbit Meatus Line and Mandibular Body Angle in Paranasal Sinus Parietoacanthial Projection(Water's Method) (코곁굴 두정비극방향 검사 시 안와이공선과 아래턱뼈 몸통각도의 상관관계를 이용한 새로운 자세잡이 기준에 관한 연구)

  • Yong-Min Son;Han-Yong Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.335-344
    • /
    • 2024
  • In this study, we aim to investigate the correlation between the lateral images of Korean skulls and the angle between the OML and the Body of the Mandible. Additionally, we seek to provide criteria for the ease of positioning in clinical settings and establish standardized imaging procedures for the PNS Water's view examination. This study was conducted on a total of 202 patients who visited the radiology department of a general hospital and examined the skull lateral radiography. In addition to the patient images, skull phantoms were also utilized, and images were obtained using GC85A and EOS equipment. In this research, abbreviations related to the angle of the Body of Mandible were defined using PACS on lateral images. Measurements were taken for various angles, including ramus of mandible angle(RIA), accurate OML angle(TIA), OML and IR Angle(OIA), total mandibular length(TML), ramus height(RH), the angle between the pogonion, gonion, and condylion(MA). The validity of these measurements was confirmed using the skull phantom in the study. The age-specific average range for RIA was 22.67° to 26.04°, with measurements of 23.14° for males and 24.78° for females. The age-related mean ranges for TIA and OIA were 35.98° to 38.31° and 72.27° to 75.25°, respectively. For males, TIA was 36.74° and OIA was 72.73°, while for females, TIA was 36.43° and OIA was 73.38°. The age-dependent measurements for TML and RH ranged from 85.73 mm to 89.60 mm and 62.60 mm to 70.87 mm, respectively. Male values were 90.54 mm and 70.78 mm, while female values were 85.13 mm and 61.54 mm for TML and RH, respectively. The age-specific average range for MA was 55.95° to 58.63°, with measurements of 57.96° for males and 57.76° for females. Correlation analysis revealed a positive correlation between RIA and OIA, as well as between RIA and TIA. Based on the results of this study, which indicate a positive correlation between the angle of the Body of Mandible and the OML, it can be inferred that adjusting the mandible vertically to align with the imaging receptor may contribute to more accurate image acquisition during PNS Water's view examination. Therefore, it is believed that there is value in utilizing this relationship as a criterion for establishing new positioning standards, which could enhance the utility of a new positioning guide.

Postoperative Clinical Outcome and Risk Factors for Poor Outcome of Foraminal and Extraforaminal Lumbar Disc Herniation

  • Bae, Jung Sik;Kang, Kyung Hee;Park, Jeong Hyun;Lim, Jae Hyeon;Jang, Il Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • Objective : We evaluated postoperative outcomes in patients who have lumbar foraminal or extraforaminal disc herniation (FELDH) and suggested the risk factors for poor outcomes. Methods : A total of 234 patients were selected for this study. Pre- and post-operative Visual Analogue Scale (VAS) and Korean version Oswestry Disability Index (KODI) were evaluated and the changes of both score were calculated. Outcome was defined as excellent, good, fair, and poor based on Mcnab classification. The percentage of superior facetectomy was calculated by using the Maro-view 5.4 Picture Archiving Communication System (PACS). Results : Paramedian lumbar discectomy was performed in 180 patients and combined lumbar discectomy was performed in 54 patients. Paramedian lumbar discectomy group showed better outcome compared with combined discectomy group. p value of VAS change was 0.009 and KODI was 0.013. The average percentage of superior facetectomy was 33% (range, 0-79%) and it showed negative correlation with VAS and KODI changes (Pearson coefficient : -0.446 and -0.498, respectively). Excellent or good outcome cases (Group I) were 136 (58.1%) and fair or poor outcome cases (Group II) were 98 (41.9%). The percentage of superior facetectomy was 26.5% at Group I and 42.5% at Group II. There was significant difference in superior facetectomy percentage between Group I and II (p=0.000). Conclusion : This study demonstrated that paramedian lumbar discectomy with preservation of facet joints is an effective and good procedure for FELDH. At least 60% of facet should be preserved for excellent or good outcomes.

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.

An Analysis of BMD Changes With Preoperative and Postoperative Premenopausal Breast Cancer Patient (폐경 전 유방암 환자의 치료 전.후 골밀도 변화 분석)

  • Kim, Su-Jin;Son, Soon-Yong;Choi, Kwan-Woo;Lee, Joo-Ah;Min, Jung-Whan;Kim, Hyun-Soo;Ma, Sang-Chull;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.279-286
    • /
    • 2014
  • The purpose of this study is to provide basic data of comparing BMD(bone mineral density) value of preoperative breast cancer patient and postoperative breast cancer patient due to bone loss with radiation/chemical therapy. The participants consisted of 254 breast cancer patients with BMD after having surgery and treatment from March 2007 to September 2013. Except for 84 patients with menopause or hysterectomy and we have analysed 171 patients. The BMD value(lumbar spine and femur) of before and after treatment from PACS by dure-energy X-ray absorptiometry was analyzed. First, we found variation of entire BMD and BMD according to treatment type, and analyzed detailed correlation by using marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types as variable. Data was analyzed by using SPSS for Windows Program(version 18.0). BMD was decreased 7.1% in lumbar spine, 3.1% in femur respectively(p<.01). Also there is relatively high decrement($0.067g/cm^2$) in group who had just chemotherapy in femur(p<.05). There is decrement depend on marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types but there was no statistical significance. The results show that BMD was decreased after treatment in premenopausal breast cancer patient, patient who had relatively high decrement need to be included high-risk group. As a result, aggressive prevention policy would be necessary.

A Study of the Quantitative, Qualitative Analysis on Optimizing Diagnostic Imaging Device Selection in Nasopharynx MRI (비 인두 자기공명 검사 시 최적의 진단영상 장치 선택에 관한 정량, 정성적 평가에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1035-1043
    • /
    • 2019
  • The object of is this research is to find out the optimal Tesla by evaluating SNR and CNR, after testing 1.5 T and 3.0 T. The randomly selected patients tested by nasopharynx MRI transmitted in PACS were applied to the research. Two MRI units(1.5 T, 3.0 T) was used for analyzing the data. As a method of analysis, in T1W highlighting and T1 fat removal images, we set up a certain area of interest and evaluated the SNR and CNR on tongue, spinal cord, masseter muscle, fat, parotid gland, and tumor tissue. We evaluated the SNR and CNR by quantitative analysis of six tissue, measuring the quality of images for uniform fat removal, magnetic sensitivity artifact on a four-point scale by qualitative analysis. The statistical significance of this date analysis was based on independent sample verification and was accepted when the P value was less than 0.05. As a result of analysis of both devices, 3.0 T was high in the quantitative evaluation, while 1.5 T was high in the qualitative evaluation. Considering the advantages and disadvantages of each device, and if the device is selected complementarily and applied to patients, it is believed that it will provide the optimal information.