• Title/Summary/Keyword: PA 필름

Search Result 55, Processing Time 0.02 seconds

The Effect of Temperature on the Nano-scale Adhesion and Friction Behaviors of Thermoplastic Polymer Films (열가소성 폴리머 필름의 나노 응착 및 마찰 거동에 대한 온도의 영향)

  • Kim, Kwang-Seop;Ando, Yasuhisa;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.23 no.6
    • /
    • pp.288-297
    • /
    • 2007
  • Adhesion and friction tests were carried out in order to investigate the effect of temperature on the tribological characteristics of poly (methylmethacrylate) (PMMA) film using AFM. The pull-off and friction forces on the PMMA film were measured under a high vacuum condition (below $1{\times}10^{-4}$ Pa) as the temperature of the PMMA film was increased from 300 K to 420 K (heating) and decreased to 300K (cooling). Friction tests were also conducted in both high vacuum and air conditions at room temperature. When the temperature was 420 K, which is 25 K higher than the glass transition temperature $(T_g)$ of PMMA, the PMMA film surface became deformable. Subsequently, the pull-off force was proportional to the maximum applied load during the pull-off force measurement. In contrast, when the temperature was under 395 K, the pull-off force showed no correlation to the maximum applied load. The friction force began to increase when the temperature rose above 370 K, which is 25 K lower than the $T_g$ of PMMA, and rapidly increased at 420 K. Decrease of the PMMA film stiffness and plastic deformation of the PMMA film were observed at 420 K in force-displacement curves. After the heating to 420 K, the fiction coefficient was measured under the air condition at room temperature and was found to be lower than that measured before the heating. Additionally, the RMS roughness increased as a result of the heating.

Analysis of Impact Acoustic Property of Apple Using Piezo-Polymer Film Sensor (고분자 압전 박막 센서를 이용한 사과의 충격 음파 특성 분석)

  • Kim, Man-Soo;Lee, Sang-Dae;Park, Jeong-Hak;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.144-150
    • /
    • 2008
  • In this study, the PVDF (polyvinylidene fluoride) piero-film sensor was applied to measure the internal quality of apple. The developed sensor detected the response signal through apple after mechanical impact on the surface of apple. The acoustical parameters at time domain such as rise time (RT), ring down count (RC), energy (EN), event duration (ED) and peak amplitude (PA) and acoustical parameter at frequency domain such as spectral density (SE) were analyzed. The size of waveform decreased as storage time of apple increased. The frequency at maximum magnitude was shifted to lower frequency band according to the storage time. The acoustical parameters showed strong relationship with storage time. The multiple linear regression equation was developed to estimate storage time of apple using the acoustical parameters at time domain and its coefficient of determination was 0.97. The internal quality of apple according to storage time is predictable using developed PVDF sensor and acoustical parameters defined in this study.

Effect of Modified Atmosphere Packaging on Postharvest Quality of Kohlrabi (콜라비의 수확 후 MA 포장에 따른 품질 유지 효과)

  • Park, Me-Hea;Choi, Ji-Weon;Kim, Yong-Bum;Kim, Myeong-Hae;Won, Hee-Yeon;Shin, Sun-Young;Kim, Ji-Gang
    • Horticultural Science & Technology
    • /
    • v.32 no.5
    • /
    • pp.655-665
    • /
    • 2014
  • The effect of modified atmosphere packaging (MAP) on kohlrabi (Brassica olerace L. gongulodes group)'s quality and antioxidant molecule during storage was examined to determine the optimal film package for maintaining freshness. To extend shelf life, MAP was tested using PE $50{\mu}m$ and oriented polypropylene (OPP) films with oxygen transmission rate (OTR) at 3,000, 10,000, $15,000mL/m^2/day/atm$. The OPP film packaging with modified oxygen transmission rate showed a delay in a weight loss and extended storage period. The package with OTR 3000 attained the desired gas composition of $O_2$ 3.2-6.7 kPa and $CO_2$ 13.1-19.8 kPa, in storage at room temperature. Kohlrabi stored in this package showed the lowest weight loss and the highest visual quality. Deterioration and off-odor were developed more rapidly in PE $50{\mu}m$ towards the end of the storage at room temperature. However, there are no differences among OTR films in visual quality and off-odor until 60 days at cold storage. Vitamin C content of kohlrabi was reduced rapidly in OTR 15000 with high transmission rate and showed less loss in PE $50{\mu}m$ and OTR 3000 in both room temperatures and cold storage. Results revealed that an OPP film with OTR 3000 extended the shelf life of kohlrabi in storage with maintained quality and vitamin C.

PE 첨가에 의한 방사성폐수지 아스팔트고화체의 특성연구

  • 김태국;손종식;김길정;안섬진;정인하
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.385-390
    • /
    • 1998
  • 방사성 페이온교환수지 아스팔트고화체를 처분장 등지에서 장기간 저장시 안전성 확보를 위하여 물리적 강도가 높고 고화체내에서 방사성핵종의 침출저항성 및 처리시 감용의 효과가 우수한 고화체 연구가 필요하게 되었다. 실험에 사용된 이온교환수지는 입상형 양이온 교환수지를 대상으로 하였으며 고화매질로서는 도로포장용으로 생산되는 직류아스팔트 60/70을 사용하였다. 고화보조제는 방사성 고체패기물 포장시 사용되어 폐기물로 발생되는 페폴리에틸렌(폐PE) 필름을 사용하였다. 실험결과 고화체의 형태안정성은 PE 함유량이 10 wt% 이상일 때 고화체 형태를 그대로 유지할 수 있으며 압축강도는 414 kPa(60 psi) 이상을 나타내었다. 최적의 운전조건은 이온교환수지, PE 함유량이 건조기준으로 각각 30~50 wt%, 10~25 wt% 이며, 고화온도는 170~20$0^{\circ}C$이다. 고화체의 침출특성은 확산 (diffusion) 으로 해석이 가능하며, 유효확산계수(De)는 Cs, Co의 경우 각각 1.621$\times$$10^{-7}$, 1.186$\times$$10^{-9}$ $\textrm{cm}^2$/day로 나타나고, Leachablity index는 각각 11.7, 13.8로 미국 원자력위원회 (NRC)가 요구하는 기준값 6보다 훨씬 높게 나타났다.

  • PDF

Polymer Thin Film of Phthalic Anhydride via Plasma Polymerization (플라즈마 중합에 의한 프탈릭 안하이드라이드 고분자 박막 필름 제조 연구)

  • Kang, Hyun Min;Basarir, Fevzian;Paek, Kwan Yeol;Yoon, Tae-Ho
    • Journal of Adhesion and Interface
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 2009
  • Polymer thin films were prepared by radio frequency (RF) plasma polymerization of phthalic anhydride (PA). First, monomer vaporization temperature ($100{\sim}160^{\circ}C$) was optimized by evaluating the thermal properties of thin films using differential scanning calorimeter (DSC) and measuring the root-mean-square (RMS) roughness with atomic force microscope (AFM) at the fixed plasma power of 10 W and time of 5 min in a continuous-wave (CW) mode. Plasma power (5~20 W) was then optimized by measuring the film solubility in solvents such as toluene, acetone, dimethylsulfoxide (DMSO) and 1 methylpyrrolidine (NMP). Next, pulsed mode plasma polymerization was also studied by varying the duty cycle of on-time (5, 20%) under optimized conditions of continuous-wave (CW) mode ($120^{\circ}C$, 10 W) in order to increase the anhydride functional groups. Finally, polymer thin films were characterized by Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analyzer (TGA) and ${\alpha}$-step.

  • PDF

Effect of Nonsolvent Additive in Casting Solutions on Polysulfone Membrane Preparation (Polysilfone 막의 제조에 있어 제막용액에 첨가된 비용매의 영향)

  • 한명진
    • Membrane Journal
    • /
    • v.6 no.3
    • /
    • pp.157-165
    • /
    • 1996
  • Polysulfone(PS) membranes were prepared from homogeneous PS solutions by the phase inversion technique. When propionic acid(PA) was added into a casting solution of n-methylpyrrolidone(NMP) and PS, precipitation rate of the solution film was accelerated. This kind of acceleration was consistent, even though a precipitating nonsolvent was changed from water to isopropanol. These phenomena were caused by decrease of nonsolvent tolerance in the casting solution due to addition of PA. PS powder was prepared by precipitation of a 3wt% solution in dimethylformamide(DMF) using ethanol as nonsolvent. Gas adsorption analysis of the powder showed that the capillary condensation sites were found in the powder structure. Membranes prepared from PS solution(15wt%) in NMP had the following characteristics of gas adsorption and water permeation. In gas adsorption analysis, the membrane precipitated using isopropanol showed low uptake of nitrogen gas and the capillary condensation sites were not found. On the contrary, a significant amount of the capillary condensation sites was found in the membrane coagulated by water, which was related to increase of nitrogen uptake. tn the membrane prepared froin the solution including PA, an increase of the Henry's law sites and the Langmuir sites was not found clearly. However, the capillary condensation sites were significantly increased, and the water transport also increased.

  • PDF

Minimization of Small Bowel Volume within Treatment Fields Using Customized Small Bowel Displacement System(SBDS) (골반부 방사선 조사야 내의 소장 용적을 줄이기 위한 Small Bowel Displacement System(SBDS)의 사용)

  • Lim Do Hoon;Huh Seung Jae;Ahn Yong Chan;Kim Dae Yong;Wu Hong Gyun;Kim Moon Kyung;Choi Dong Rak;Shin Kyung Hwan
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 1997
  • Purpose : Authors designed a customized Small Bowel Displacement System (SBDS) to displace the small bowel from the Pelvic radiation fields and minimize treatment-related bowel morbidities. Materials and Methods : From August 1995 to Mar 1996. 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized styrofoam compression device which can displace the small bowel from the radiation fields and an individualized immobilization abdominal board for easy daily setup in prone position After opacifying the small bowel with Barium3, the patients were laid Prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The areas of the small bowel included in the radiation fields with and without the SBDS were compared. Results : Using the SBDS, the mean small bowel area was reduced by $59\%;on\;PA\;and\;51\%$ on LAT films (P=0.0001). In six Patients (6/55. $11\%$), it was Possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Only $15\%$ (8/55) of patients treated with the SBDS manifested diarrhea requiring medication. Conclusion : The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and reduce the radiation therapy morbidities. Compliance with setup is excellent when the SBDS is used.

  • PDF

Effect of Ozonated Water and Chlorine Water Wash on the Quality and Microbial De-contamination of Fresh-cut Carrot Shreds (오존수 및 염소수 세척이 신선편이 당근의 품질 및 미생물억제에 미치는 영향)

  • Kim, Ji-Gang;Luo, Yaguang;Lim, Chai-Il
    • Food Science and Preservation
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2007
  • Little information exists on how wash operations affect water quality, or the efficacy of sanitizers on vegetable quality and microbial reduction in fresh-cut carrot shreds. This study evaluated the efficacy of chlorine and ozone in reducing microbial loads and maintaining vegetable quality of carrot shreds. Fresh-cut carrot shreds were teated with various chlorine and ozone concentrations for differing times. The samples were then centrifuged to remove excess water, packaged in film, and stored at $5^{\circ}C$. The result indicated that varying the ozonated water wash time affected microbial growth the development of unpleasant odors, color, and the overall quality of carrot shreds. Ozonated water washing for 20 min maintained vegetable quality by inhibiting unpleasant odors, the development of whiteness, and by reducing microbial populations. A single chlorine water wash was effective and resulted in better vegetable quality when compared with two washes. Samples washed for 20 min in ozonated water, however, had better vegetable quality and smaller microbial counts compared to samples washed once in chlorine water A 20 min ozonated water wash is an attractive method for the maintenance of vegetable quality and shelf-life in fresh-cut carrot shreds.

Quality changes of fresh-cut winter squash treated with different postharvest ripening periods and packaging methods (신선편이 단호박 원료의 후숙기간 및 가공 후 포장방법에 따른 저장 중 품질변화)

  • Kim, Ji-Gang;Choi, Ji-Woen;Cho, Mi-Ae
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • This study was conducted in order to evaluate the effect of postharvest ripening periods and packaging methods on maintaining the quality of fresh-cut winter squash. Winter squash (var. Bouchang) was ripened at $22^{\circ}C$ for 1 or 2 weeks after harvest. The samples were washed in tap water, sanitized in $100{\mu}L/L$ chlorine water, peeled, and cut into 16 parts. Samples were then vacuum packaged or non-vacuum packaged in $80{\mu}m$ nylon/polyethylene (Ny/PE) films and stored at $5^{\circ}C$ for 21 days. Results indicated that different postharvest ripening periods affected gas concentration, firmness, off-odor development, color, and overall quality of fresh-cut winter squash. Samples treated with 2-week ripening periods maintained quality with higher redness value and soluble solid content (SSC) and lower $CO_2$ concentration and off-odor development compared to samples treated with a 1-week ripening period. Non vacuum packaging was effective in increasing visual quality and reducing off-odor development. A combination treatment of 2-week ripening periods and non-vacuum packaging maintained good quality with the lowest off-odor development and the highest visual quality scores at the end of the storage period.

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.