일반적으로 광통신 시스템은 전기적 신호를 광신호로 바꾸어 주는 송신부와 전송되어 온 광신호를 전기적 신호로 변환하여 부는 수신부 및 송수신부 간의 정보를 전송해 주는 경로인 정보채널로 구성된다. 광통신 시스템의 동작속도를 개선하기 위해서는 송신부 및 수신부 회로들의 고속화가 필요하다. 디멀티플렉서는 고 비트율을 갖는 하나의 직렬 스트림을 원래의 낮은 비트율을 갖는 여러 병렬 스트림들로 환원하는 장치로, 광통신 시스템의 수신부에 사용된다. 본 논문에서는 고속 및 저전력 소자로 주목을 받고 있는 에미터 크기가 2$\times$8um2 인 SiGe HBT를 사용하여 1 : 4 디멀티플렉셔를 설계하였다. 설계된 회로의 동작속도는 10Gbps, 입력전압 및 출력전압은 각각 800mVp-p와 400mVp-p, 20-80% 간의 상승시간 및 하강시간은 각각 37ps와 36ps이며, 전력소모는 1.40W이다.
IPMC(Ionic Polymer-Metal Composite) is a highly sensitive actuator that shows a large deformation in presence of low applied voltage. Generally, IPMC can be fabricated by electroless plating of platinum on both sides of a Nafion (perfluorosulfonic acid) film. When a commercial Nafion film is used as a base structure of the IPMC membrane, the micro-pump structure and the IPMC membrane are fabricated separately and then later assembled, which makes the fabrication inefficient. Therefore, fabrication of an IPMC membrane and the micro-pump structure on a single wafer without the need of assembly have been developed. The silicon wafer was partially etched to hold liquid Nafion to be casted and a 60-${\mu}{\textrm}{m}$ thick IPMC membrane was realized. IPMC membranes with various size were fabricated by casting and they showed 4-2${\mu}{\textrm}{m}$ displacements from $4mm{\times}4mm$ , $6mm{\times}6mm$, $8mm{\times}8mm$ membranes at the applied voltage ranging from 2Vp-p to 5Vp-p at 0.5Hz. The displacement of the fabricated IPMC membranes is fairly proportional to the membrane area and the applied voltage.
We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.
This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).
본 논고의 목적은 듀얼 에너지 시스템의 금속 인공물 감약 (MAR) 기법을 팬텀과 환자를 대상으로 적용하여보고 그 유용성에 대해서 알아보고자 한다. 사용한 장비는 GE사(社)의 750HD CT이고 AW 4.5 볼륨 share 4 워크스테이션에서 영상 분석을 하였다. 팬텀으로는 victoreen사(社)의 사람 모형 흉부팬텀을 사용하였고 사람 대상은 2010년 12월 20일부터 2011년 2월 10일까지 금속물질이 삽입된 환자 25명을 대상으로 목 부위와 복부 부위에 MAR 알고리즘을 적용하였다. 사용한 파라미터는 복부검사의 경우 GSI-4Body-Large 0.9 sec 40 mm이고 목 부위에서는 GSI-3Body-Medium 0.5 sec 40 mm를 선택하여 시행하였다. 영상시험은 국립암센터 CT영상실에서 기본적으로 시행하고 있는 프로토콜에 MAR 옵션을 적용하여 동일하게 시행하였다. 영상분석은 MAR기법을 적용한 영상과 적용하지 않은 영상에서 검은색 인공물과 줄무늬 인공물이 있는 부위에 관심부위 (ROI)를 설정한 후 hounsfield unit(HU)과 노이즈를 이용한 정량적 평가를 하였고 임상 경험이 풍부한 의사와 방사선사가 CT영상에 대한 평가를 하여 MAR 알고리즘에 대한 유용성을 비교하였다. 환자 대상 시험 결과 MAR 알고리즘을 적용함으로서 금속 인공물이 있는 부위에서의 검은색 인공물(금속이 있는 부위) 과 줄무늬 인공물이 있는 영상에서 HU의 p값이 각각 p=0.01과 p=0.04를 보였지만 금속 인공물의 영향에서 벗어난 부위에서의 노이즈는 오히려 증가하는 모습을 보였다(p=0.05). 그리고 그 외의 영상(금속이 있는 부위에서 1 cm 떨어진 단면 영상) 에서 검은색 인공물과 줄무늬 인공물 부위의 HU와 노이즈의 p값에 대해서는 통계적 유의성은 만족하지 못하였지만 대체적으로 MAR알고리즘을 적용함으로서 금속인공물 발생이 감약 되는 결과를 보였다. 결론적으로 금속 물질이 삽입된 환자의 경우에 MAR 알고리즘을 적용함으로서 조직의 선예도가 적용하지 안했을 때보다 증가하였고 검은색 인공물 발생 또한 개선되는 모습을 보였다.
본 연구에서는 전도성 직물을 기반으로 동작 센서로 구현하여 팔의 굽힘, 폄 동작에 따른 센서의 전기저항의 변화를 측정, 분석함으로써 관절 동작을 효과적으로 측정 할 수 있는 직물 센서의 요건을 탐색하였다. 이를 위해 두 가지 편직물인 'L'직물과 'W'직물 양면에 Single Wall Carbon Nano-Tube(SWCNT) 코팅을 한 후 이를 다양한 형태로 후가공하여 직물 센서를 개발하고 암 밴드에 부착하였다. 직물 센서는 코팅용 바탕 직물의 종류(2가지), 센서의 부착 방법(2가지), 센서의 layer 수(2가지), 센서의 길이(3가지), 센서의 너비(2가지)의 총 48개로 구성되었다. Con-Trex MJ에 48개의 암 밴드를 입힌 인체 모형 팔을 대상으로 직물 동작 센서의 성능을 평가하였다. 인체 모형 팔에 입혀진 총 48개의 암 밴드 각각에 대해서 frequency: 0.5Hz, ROM: $20^{\circ}{\sim}120^{\circ}$ 에서 굽힘과 폄 동작을 반복하도록 조정하였고, 48개 각 사례 당 세 세트(set)씩 반복 측정한 전압값을 기록하였다. 전압값을 peak-to-peak voltage(Vp-p)의 base line의 균일성, 동일 세트 내 Vp-p의 균일성, 세 세트 간의 Vp-p의 균일성을 기준으로 평가하고 분석한 결과, SWCNT 코팅된 'L' 직물을 두 겹으로 구성하여 열고정 방식으로 부착한 $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$ 크기의 직물 센서와, SWCNT 코팅된 'W' 직물을 두 겹으로 구성하고 열고정 방식으로 부착한 $50{\times}10mm$ 크기의 직물 센서가 전체 변화율 5%이내의 가장 균일하고 안정적인 신호값을 나타내었다. 이상의 연구 결과를 통해 SWCNT 코팅 소재를 다양한 형태로 가공해 직물 센서로 구현했을 때 인체의 사지 동작을 측정할 수 있는 센서로서 적합함을 확인하였고, 최적의 센서 형태를 규명하였다.
Purpose: The purpose of this study was to investigate the effect of self-postural control on foot pressure in subjects with forward head posture. Methods: Forty-two healthy adults were recruited in this study. Participants were divided into two groups: The forward-head postural (FHP) group (craniovertebral angle<$53^{\circ}$, n=22) and the control group (craniovertebral angle${\geq}53^{\circ}$, n=20). In the FHP group, foot pressure was measured using three different standing postures: Comfortable standing posture (CSP), subjective neutral standing posture (SNSP), and neutral standing posture with visual feedback (NSP-VP). Each position was performed in random order. In the control group, foot pressure was measured only using the comfortable standing posture. Results: With respect to CSP and SNSP, there was a significant difference on heel pressure between the two groups (p<0.05). Regarding NSP-VP, however, there was no significant differences on heel pressure between the two groups (p>0.05). Conclusion: We suggest that cervical posture control using visual feedback has a positive effect on the distribution of foot pressure in subjects with forward head posture.
The rational synthesis of efficient transitional metal phosphides (TMPs) could revolutionize green hydrogen production via water splitting. Hydrogen, with the highest energy density among fuels, stands out as an excellent alternative to address environmental issues and ensure sustainable future energy generation. However, the limited availability of state-of-the-art electrocatalysts like Pt/C and RuO2, used for the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER), respectively, necessitates the development of cost-effective and non-noble electrocatalysts for green hydrogen production. In this context, we present a novel heterointerface-modulated heterostructure design comprising ultrathin nanosheets of a 3D Co2P/VP heterostructure on a conductive nickel foam substrate. This heterostructure demonstrates remarkably low overpotentials of 96 mV for HER and 237 mV for OER at 10 mA cm-2. The material's robust electrochemical kinetics are further evidenced by low Tafel slopes of 68.28 mV dec-1 and 116.54 mV dec-1, respectively.
목적: 한국에 백신이 도입된 이후 장염으로 입원한 소아에서 확인된 로타바이러스 유전형의 분포를 알아보고자 하였다. 방법: 2009년 8월부터 2013년 6월 사이에 급성 위장관염으로 입원한 소아에게서 수집된 201개의 로타바이러스 양성 대변 검체를 대상으로 로타바이러스 유전형 분석이 시행되었다. 결과: G 유전형은 G9 (33.3%), G1 (22.4%), G3 (15.9%), G2 (6.0%), G4 (3.0%), G10 (1.5%)이었고 혼합형(15.4%) 및 분류불능(2.5%)이 관찰되었다. P 유전형은 P[4] (45.3%)과 P[8] (43.8%)가 주로 검출되었고 혼합형(10.4%)과 P[2] (0.5%)가 발견되었다. G9P[4] 유전형이 2010/2011년에 자주 검출되었으나 이후에 G1P[8] 유전형이 주로 검출되었다. 결론: 로타바이러스 백신 도입 이후 2009-2013년 동안 G1, G3 및 G9이 번갈아가며 주로 검출되는 것을 확인하였다.
Kim, Jin-Ik;Kaufman, Randal J.;Back, Sung Hoon;Moon, Ja-Young
Molecules and Cells
/
제42권11호
/
pp.783-793
/
2019
When endoplasmic reticulum (ER) functions are perturbed, the ER induces several signaling pathways called unfolded protein response to reestablish ER homeostasis through three ER transmembrane proteins: inositol-requiring enzyme 1 (IRE1), PKR-like ER kinase (PERK), and activating transcription factor 6 (ATF6). Although it is important to measure the activity of ATF6 that can indicate the status of the ER, no specific cell-based reporter assay is currently available. Here, we report a new cell-based method for monitoring ER stress based on the cleavage of $ATF6{\alpha}$ by sequential actions of proteases at the Golgi apparatus during ER stress. A new expressing vector was constructed by using fusion gene of GAL4 DNA binding domain (GAL4DBD) and activation domain derived from herpes simplex virus VP16 protein (VP16AD) followed by a human $ATF6{\alpha}$ N-terminal deletion variant. During ER stress, the GAL4DBD-VP16AD(GV)-$hATF6{\alpha}$ deletion variant was cleaved to liberate active transcription activator encompassing GV-$hATF6{\alpha}$ fragment which could translocate into the nucleus. The translocated GV-$hATF6{\alpha}$ fragment strongly induced the expression of firefly luciferase in HeLa Luciferase Reporter cell line containing a stably integrated 5X GAL4 site-luciferase gene. The established double stable reporter cell line HLR-GV-$hATF6{\alpha}$(333) represents an innovative tool to investigate regulated intramembrane proteolysis of $ATF6{\alpha}$. It can substitute active pATF6(N) binding motif-based reporter cell lines.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.