• Title/Summary/Keyword: P300 speller

Search Result 4, Processing Time 0.023 seconds

The effects of the methods of eye gaze and visual angles on accuracy of P300 speller (시선응시 방법과 시각도가 P300 문자입력기의 정확도에 미치는 영향)

  • Eom, Jin-Sup;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.91-100
    • /
    • 2014
  • This study was to examine how visual angle of matrix corresponding to the physical properties of P300 speller and eye gaze corresponding to the user's personal characteristics influence on the accuracy of P300. Visual angle of the matrix was operated as the distance between the user and the matrix and three groups were composed: 60 cm group, 100 cm groups, and 150 cm group. Eye gaze methods was consisted three conditions. Head moving condition was putting eye gaze using head, pupil moving condition was moving pupil with the head fixed, while the eye fixed condition is to fix the eye gaze at the center of the matrix. The results showed that there was significant difference in the accuracy of P300 speller according to the eye gaze method. The accuracy of the head moving condition was higher than the accuracy of pupil moving conditions, accuracy of pupil moving conditions was higher than the accuracy of the eye fixed conditions. However, the effect of visual angle of matrix and interaction effect were not significant. When P300 amplitude of target character was measured depending on how you stare at the target character, P300 amplitude of the head moving condition was greater than P300 amplitude of the pupil moving condition. There was no significant difference in the error distribution in head moving condition and pupil moving condition, while there was a significant difference between two eye gaze conditions and fixed gaze condition. The error was located at the neighboring characters of the target character in head moving condition and pupil moving condition, while the error was relatively distributed widely in fixed eye condition, error was occurred with high rate in characters far away from the center of matrix.

P300 speller using a new stimulus presentation paradigm (새로운 자극제시방법을 사용한 P300 문자입력기)

  • Eom, Jin-Sup;Yang, Hye-Ryeon;Park, Mi-Sook;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2013
  • In the implementation of a P300 speller, rows and columns paradigm (RCP) is most commonly used. However, the RCP remains subject to adjacency-distraction error and double-flash problems. This study suggests a novel P300 speller stimuli presentation-the sub-block paradigm (SBP) that is likely to solve the problems effectively. Fifteen subjects participated in this experiment where both SBP and RCP were used to implement the P300 speller. Electroencephalography (EEG) activity was recorded from Fz, Cz, Pz, Oz, P3, P4, PO7, and PO8. Each paradigm consisted of a training phase to train a classifier and a testing phase to evaluate the speller. Eighteen characters were used for the target stimuli in the training phase. Additionally, 5 subjects were required to spell 50 characters and the rest of the subjects were to spell 25 characters in the testing phase. Classification accuracy results show that average accuracy was significantly higher in SBP as of 83.73% than that of RCP as of 66.40%. Grand mean event-related potentials (ERPs) at Pz show that positive peak amplitude for the target stimuli was greater in SBP compared to that of RCP. It was found that subjects tended to attend more to the characters in SBP. According to the participants' ratings on how comfortable they were with using each type of paradigm on 7-point Likert scale, most subjects responded 'very difficult' in RCP while responding 'medium' and 'easy' in SBP. The result showed that SBP was felt more comfortable than RCP by the subjects. In sum, the SBP was more correct in P300 speller performance as well as more convenient for users than the RCP. The actual limitations in the study were discussed in the last part of this paper.

  • PDF

Analysis of Performance of EEG Measurement Device for Human Computer Interface (휴먼 컴퓨터 인터페이스를 위한 뇌파 측정 장치 성능 분석)

  • Choi, Jong-Suk;Bang, Jae Won;Lee, Eui Chul;Park, Kang Ryoung;Whang, Mincheol;Lee, Jung Nyun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.490-493
    • /
    • 2011
  • 최근 사용자와 컴퓨터간의 상호작용이 가능한 사용자 인터페이스(UI, User Interface)에 대한 연구가 활발히 진행되고 있다. 이중 키보드나 마우스, 리모컨과 같은 별도의 입력장치가 없이 뇌의 활동으로부터 발생하는 생체신호를 이용하여 사용자의 생각만으로 컴퓨터와 커뮤니케이션을 할 수 있는 뇌만으로 컴퓨터와 커(BCI, Brain-Computer Interface) 시스템이 각광을 받고 있다. 본 연구에서는 뇌의 생체신호로는 뇌전도도(EEG, Electroencephalogram)를 사용하였으며, 이를 통하여 P300 speller 실험을 수행하였다. P300 speller 실험을 통하여 발생된 뇌전도도를 취합하여 P300(사건 관련 전위(ERP, Event-related potential)에서 자극 제시 약 300msec 후에 정점에 달하는 정파)을 분석하였다.

  • PDF

Development of Online Speller using Non-contact Blink Detection Glasses (비접촉 눈 깜박임 측정 안경형 디바이스를 이용한 실시간 스펠러의 구현)

  • Lee, Jeong Su;Lee, Hong Ji;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.283-290
    • /
    • 2015
  • We proposed blink based online speller for the locked-in syndrome (LIS) patients, paralyzed in nearly all voluntary muscles expect for the eyes, with a simple and easy-to-use eye blink detection glasses. Electrooculogram (EOG) is the golden standard method of eye movement or blink measurement with Ag/AgCl electrodes. However, this method has several drawbacks such as skin irritation and dehydration of conductive gel. To resolve the shortcomings, we used a blink detection system based on a transparent capacitively coupled electrode, which is conductive indium tin oxide (ITO) films. The films make it possible to measure eye blink without direct skin contact and obstruction of field of view. We finally developed user-friendly blink based online speller with the blink detection system. To classify voluntary and non-voluntary blink, we used the double blink for command of the speller. The online speller experiment result with six healthy subjects shows that mean accuracy is 98.96% and letter per minute (LPM) is 4.73, which are better result by comparison with conventional P300 or auditory brain-computer interface (BCI) paradigm. The result of the experiment demonstrates the possibility of applying the proposed system as a communication method for the LIS patients.