• Title/Summary/Keyword: P.N.T

Search Result 5,341, Processing Time 0.031 seconds

Synthesis and Crystal Structure of $Me_2Pt(PPh_2CH_2C(t-Bu)=N-N=CMe(2-py)-\kappa^2N,P)$ ($Me_2Pt(PPh_2CH_2C(t-Bu)=N-N=CMe(2-py)-\kappa^2N,P)$의 합성 및 결정 구조)

  • Cho Sung Il;Kang Sang Ook;Chang K.
    • Korean Journal of Crystallography
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2004
  • An organometallic complex. $Me_2Pt(PPh_2CH_2C(t-Bu)=N-N=CMe(2-py)-\kappa^2N,P)$ was synthesized from phosphinohydrazone $Ph_2PCH_2C(t-Bu)=NNH_2$, 2-acetylpyridine, and $[PtMe2({\mu}-SMe_2)]_2$. The molecular structure of this complex has been determined by X-ray diffraction. Crystallographic data: monoclinic, space group $P2_1/n,\;a=11.6926(7)\;{\AA},\;b=15.6607(19)\;{\AA},\; c=14.6125(6)\;{\AA},\;\beta=93.018(4)^{\circ},\;Z=4,\;V=2672.0(4)\;{\AA}^3$. The structure was solved by direct methods and refined by full-matrix least-squares methods to give a model with a reliability factor R = 0.0363 for 5238 reflections.

ISOLATION NUMBERS OF INTEGER MATRICES AND THEIR PRESERVERS

  • Beasley, LeRoy B.;Kang, Kyung-Tae;Song, Seok-Zun
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.3
    • /
    • pp.535-545
    • /
    • 2020
  • Let A be an m × n matrix over nonnegative integers. The isolation number of A is the maximum number of isolated entries in A. We investigate linear operators that preserve the isolation number of matrices over nonnegative integers. We obtain that T is a linear operator that strongly preserve isolation number k for 1 ≤ k ≤ min{m, n} if and only if T is a (P, Q)-operator, that is, for fixed permutation matrices P and Q, T(A) = P AQ or, m = n and T(A) = P AtQ for any m × n matrix A, where At is the transpose of A.

Treatment of Industrial Wastewater by Electrochemical Method (전기화학적방법을 이용한 산업폐수 처리)

  • Cho, Ju-Sik;An, Myoung-Sub;Lee, Hong-Jae;Heo, Jae-Seon;Sohn, Bo-Kyoon;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.134-141
    • /
    • 2000
  • For electrochemical treatment of industrial wastewater, the effects of voltage, distance between electrodes, initial pH and NaCl concentrations on removal of pollutants were investigated in a batch electrolysis system. Temperature and pH in electrochemical reactor increased with increase in supplied voltage, but no significant change in EC was found. Removal of COD, turbidity, T-N and T-P were also enhanced with increase in the voltage. On the conditions of short distances between electrodes and long electrochemical reaction times, it was found that COD and T-N were very effectively removed in the system. Regardless of the distances, more than 80% of turbidity and T-P were removed at the beginning of reaction. When initial pH of the wastewater was about 7, the highest efficiency of COD removal was found in the system. On the other hand, removal efficiency of turbidity was unlikely affected by initial pH of the wastewater. T-N removal was increased with increase in initial pH. T-P was successfully removed in the pH range of 5 to 9 with varying removal efficiency of 79 to 96% after 2 minutes of electrochemical reaction time. Addition of NaCl into the electrochemical reactor increased removal efficiency of electrochemical treatment. The highest removal efficiency of COD and T-P, turbidity and T-N was obtained at NaCl concentrations of 500mg/L, 1,000 mg/L and 500mg/L, respectively.

  • PDF

MODIFIED KRASNOSELSKI-MANN ITERATIONS FOR NONEXPANSIVE MAPPINGS IN HILBERT SPACES

  • Naidu, S.V.R.;Sangago, Mengistu-Goa
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.3_4
    • /
    • pp.753-762
    • /
    • 2010
  • Let K be a nonempty closed convex subset of a real Hilbert space H. Let T : K $\rightarrow$ K be a nonexpansive mapping with a nonempty fixed point set Fix(T). Let f : K $\rightarrow$ K be a contraction mapping. Let {$\alpha_n$} and {$\beta_n$} be sequences in (0, 1) such that $\lim_{x{\rightarrow}0}{\alpha}_n=0$, (0.1) $\sum_{n=0}^{\infty}\;{\alpha}_n=+{\infty}$, (0.2) 0 < a ${\leq}\;{\beta}_n\;{\leq}$ b < 1 for all $n\;{\geq}\;0$. (0.3) Then it is proved that the modified Krasnoselski-Mann iterative sequence {$x_n$} given by {$x_0\;{\in}\;K$, $y_n\;=\;{\alpha}_{n}f(x_n)+(1-\alpha_n)x_n$, $n\;{\geq}\;0$, $x_{n+1}=(1-{\beta}_n)y_n+{\beta}_nTy_n$, $n\;{\geq}\;0$, (0.4) converges strongly to a point p $\in$ Fix(T} which satisfies the variational inequality

    $\leq$ 0, z $\in$ Fix(T). (0.5) This result improves and extends the corresponding results of Yao et al[Y.Yao, H. Zhou, Y. C. Liou, Strong convergence of a modified Krasnoselski-Mann iterative algorithm for non-expansive mappings, J Appl Math Com-put (2009)29:383-389.

INEQUALITIES OF OPERATOR POWERS

  • Lee, Eun-Young;Lee, Mi-Ryeong;Park, Hae-Yung
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Duggal-Jeon-Kubrusly([2]) introduced Hilbert space operator T satisfying property ${\mid}T{\mid}^2{\leq}{\mid}T^2{\mid}$, where ${\mid}T{\mid}=(T^*T)^{1/2}$. In this paper we extend this property to general version, namely property B(n). In addition, we construct examples which distinguish the classes of operators with property B(n) for each $n{\in}\mathbb{N}$.

  • PDF

Water Quality Management using WASPS & WASP Builder for a Basin of an Agricultural Reservoir (WASP5 & WASP Builder을 이용한 농업용저수지 유역의 수질관리)

  • Chung, Paul-Gene;Goh, Hong-Seok;Hyun, Mi-Hee;Lee, Eun-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.422-431
    • /
    • 2004
  • Water quality modeling was performed for the purpose of diagnosis and prediction of water quality in Gyoung Choen reservoir, using EUTR05/WASP Build model. WASP Builder is capable of visual display in window and it has an advantage of updating and modification for data. Field data of 1992, Spring, Summer, and Fall, were used to calibrate model and these results were validated using data of 2000, Spring, Summer, and Fall. The reservoir was divided into 4 epilimnion segments. Water quality system for modeling were consist of BOD, Chlorophyll-a, DO, $NH_3-N$, $NO_3-N$, T-N, $PO_4-P$, T-P. The results of water quality modelling using EUTR05/WASP Builder, a range of the Correlation for calibration of BOD, T-N, T-P, and Chlorophyll-a according to three seasons are 0.63~0.90, 0.81~0.97, 0.75~0.98, and 0.77~0.98 respectively. And the correlation between simulated and observed values for verification of BOD, T-N, T-P, and Chlorophyll-a according to three seasons are 0.93, 0.94, 0.81, and 0.80 respectively. Among the pollutant sources for a basin of the Gyoung Choen reservoir, generated amount of livestock is the highest and BOD, T-N, T-P of generated loading percentage are 94%, 81%, and 95%. So, we suppose that inflow load amount will decrease 50% and increase 50% only livestock about current load amount. If increasing load amount of livestock 50% in segment 2 and 3, BOD, T-N, and T-P simulated increasing to range of $0.02~0.15mg/{\ell}$, $0.029~0.08mg/{\ell}$, $0.011~0.029mg/{\ell}$ in comparison with current water quality

Electrical Characteristics of Ti Self-Aligned Silicide Contact (Ti Self-Aligned Silicide를 이용한 Contact에서의 전기적 특성)

  • 이철진;허윤종;성영권
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.170-177
    • /
    • 1992
  • Contact resistance and contact leakage current of the Al/TiSiS12T/Si system are investigated for NS0+T and PS0+T junctions. SALICIDE (Self Aligned Silicide) process was used to make the Al/TiSiS12T/Si system. Titanium disilicide is one of the most common silicides because of its thermal stability, ability to form selective formation and low resistivity. In this paper, RTA temperature effect and Junction implant dose effect were evaluated to characterize contact resistance and contact leakage current. The TiSiS12T contact resistance to NS0+T silicon is lower than that to PS0+T silicon, and TiSiS12T of contact leakage current to NS0+T silicon is lower than that to PS0+T silicon. Contact resistance and contact leakage current of the Al/TiSiS12T/Si system by this method were possible for VLSI application.

Transmission Interval Optimization by Analysis of Collision Probability in Low Power TPMS (저전력 운영 TPMS에서 충돌 확률 분석을 통한 전송주기 최적화)

  • Lim, Sol;Choi, Han Wool;Kim, Dae Jin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.364-371
    • /
    • 2017
  • TPMS is a vehicle electric system that measures the air pressure of a tire, and informs the driver of current tire states. The TPMS sensor typically uses unidirectional communication for small size, light weight, and low power. The transmission period of the sensor indicates the service quality of monitoring the tire. In order to determine the optimal transmission period, frame collision probability and the life time of the sensor should be analyzed. In this paper, collision probability model using Venn diagram is designed in low power TPMS with the normal and warning mode. And the life time and a collision probability were analyzed with the ratio(n) of the normal mode to warning mode transmission period. As a result, $T_{nP}=31sec$ and $T_{wP}=2.4sec$ at 5 years, and $T_{nP}=71sec$ and $T_{wP}=2.5sec$ at 7 years.

Pressure Analyses at the Planar Surface of Liquid-Vapor Argon by a Test-Area Molecular Dynamics Simulation

  • Lee, Song-Hi
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.9
    • /
    • pp.3039-3042
    • /
    • 2012
  • Pressure tensors at the planar surface of liquid-vapor argon are evaluated from the virial theorem, Irving-Kirkwood, and Harasima versions using a test-area molecular dynamics simulation method through a Lennard-Jones intermolecular potential at two temperatures. We found that the normal and transverse components of the pressure tensor, $p_N(z)$ and $p_T(z)$, obtained from the virial theorem and Harasima version are essentially the same. The normal component of the pressure tensor from Irving-Kirkwood version, $p_N^{IK}(z)$, is shown to be a nearly constant at the lower temperature, independent of z, as agreed in a previous study, but not for $p_N^H$(z), while the transverse components, $p_T^{IK}(z)$ and $p_T^H(z)$, are almost the same. The values of surface tension for both versions computed from $p_N(z)-p_T(z)$ are also the same and are fully consistent with the experimental data.