• 제목/요약/키워드: P-Y curves

Search Result 993, Processing Time 0.034 seconds

Evaluation of Dynamic Group Pile Effect in Dry Sand by Centrifuge Model Tests (원심모형 실험을 이용한 건조토 지반에서의 군말뚝 효과 분석)

  • Yoo, Min-Taek;Cha, Se-Hwan;Choi, Jung-In;Han, Jin-Tae;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.1
    • /
    • pp.67-77
    • /
    • 2012
  • In this study, a series of centrifuge shaking-table tests for a $3{\times}3$ group pile and a single pile applied by sinusoidal wave was performed in dry sand for various pile spacings, ranging from three to seven times the pile diameter. A comparison of centrifuge tests of both single pile and group pile showed that the lateral ground response of the group pile was smaller than that of the single pile. In addition, the reduction in subgrade reaction for the group pile increased with decreasing pile spacing. The side piles, that is, the 1st row and 3rd row piles showed identical dynamic p-y behavior and the center pile in the 2nd row caused a lower reduction effect compared with the 1st and 3rd row piles. From the comparison between the p-y curves of the 2nd row piles, it was found that the lateral ground response of the outer pile in the 2nd row was less than that of the center pile in the 2nd row. The p-multipliers for the side piles, for the center pile and for the outer pile ranged from 0.28 to 0.77, from 0.55 to 1.0 and from 0.39 to 0.87, respectively.

Measurements of Mid-arm Circumference(MAC) and Mid-arm Circumference/Head Circumference (MAC/HC) Ratio as Indices of Nutritional Status in Newborn Infants (신생아 신체 발육지표로서의 중앙 상완위 및 중앙 상완위와 두위비의 측정)

  • Lee, Jae-Jun;Lee, Kyung-A;Lee, Young-Hwan;Shin, Son-Moon
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.160-166
    • /
    • 1994
  • Mid-arm circumference and mid-arm circumference/head circumference ratio(MAC/HC) were measured in 207 AGA(appropriate for gestational age) infants delivered at 26 to 42 weeks of gestation from January 1990 to December 1993 in Yeungnam University Hospital, Taegu, Korea. There were linear relationships between MACs and MAC/HC ratios and gestational age(MAC : y=0.3181x - 2.2069, r=0.81, p<0.001 ; MAC/HC ratio : y=0.0049x+0.1128, r=0.62, ; < 0.001). Using standard curves of MAC and MAC/HC ratio according to the gestational age, measurement of MAC or MAC/HC ratio can be a noninvasive, simple method to evaluate the intrauterine growth of newborn infants and the nutritional status of growing premature infants.

  • PDF

A small-area implementation of public-key cryptographic processor for 224-bit elliptic curves over prime field (224-비트 소수체 타원곡선을 지원하는 공개키 암호 프로세서의 저면적 구현)

  • Park, Byung-Gwan;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1083-1091
    • /
    • 2017
  • This paper describes a design of cryptographic processor supporting 224-bit elliptic curves over prime field defined by NIST. Scalar point multiplication that is a core arithmetic function in elliptic curve cryptography(ECC) was implemented by adopting the modified Montgomery ladder algorithm. In order to eliminate division operations that have high computational complexity, projective coordinate was used to implement point addition and point doubling operations, which uses addition, subtraction, multiplication and squaring operations over GF(p). The final result of the scalar point multiplication is converted to affine coordinate and the inverse operation is implemented using Fermat's little theorem. The ECC processor was verified by FPGA implementation using Virtex5 device. The ECC processor synthesized using a 0.18 um CMOS cell library occupies 2.7-Kbit RAM and 27,739 gate equivalents (GEs), and the estimated maximum clock frequency is 71 MHz. One scalar point multiplication takes 1,326,985 clock cycles resulting in the computation time of 18.7 msec at the maximum clock frequency.

An Analysis of Near-infrared Light Curves of δ Scuti Variable BO Lyn (δ Scuti형 변광성 BO Lyn의 근적외선 광도곡선 분석)

  • Lim, Ji-Hye;Sohn, Jungjoo
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.389-397
    • /
    • 2016
  • In order to investigate the light curve difference in visual and infrared wavelength of ${\delta}$ Scuti variable Bo Lyn, observations were performed using BOAO 1.8m reflecting telescope and an infrared detector, KASINICS, with J, H, and Ks filters. Infrared light curves of total 7 nights were obtained between March and April in 2011, and those were compared to the V-filter light curve to examine the differences in period, time of maximum light, amplitude, and shape. From the periodic analysis of infrared light curve, a single frequency of $f_1=10.712cycle/day$, $P=0.09335{\pm}0.00002days$ was obtained, and there was no difference in the period along different wavelengths. In the infrared light curve, a frequency of $2f_1$ was detected. This frequency well explains the asymmetric shape of light curve, one of the characteristics of high-amplitude ${\delta}$ Scuti variables. We compared the locations of the measured infrared maxima and the predicted maxima of V-filter, finding that the times of maxima were delayed about 0.3 phase at infrared wavelengths. Amplitude ratios were adopted to be ${\Delta}J/{\Delta}V=0.328$, ${\Delta}H/{\Delta}V=0.216$, and ${\Delta}Ks/{\Delta}V=0.211$, with the range of variation being smaller at longer wavelengths. It seems that the differences in the times of maxima and amplitude occurred because the changes in brightness of a pulsating variable star are mainly caused by the change in temperature.

Labeling and Biodistribution of Re-188-DTPA (Diethylenetriaminepentaaceticacid) (Re-188-DTPA (Diethylenetriaminepentaacetic acid)의 표지와 생체내 분포)

  • Lee, Jin;Kim, Young-Ju;Chang, Young-Soo;Jeong, Jae-Min;Shin, Seung-Ae;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.427-432
    • /
    • 1997
  • Re-188 is useful candidate for therapeutic radionuclide because it has a physical half life of 17 hours, contains beta emissions suitable for therapy(maximum energy 2.12MeV) and emits a gamma ray that is suitable for quantitative diagnostic scanning(155keV). To use Re-188 as a radionuclide compound of angioplasty balloon radiotherapy, we investigated the labelling method and biodistribution of Re-188-DTPA We postulated that labeled Re-188-DTPA is preferable because it would be excreted via urinary system more easily than other compounds. To label Re-188 with DTPA, 1ml of 222MBq(6mCi) of Re-188 was added to DTPA solution(DTPA 20mg, $SnCl_2{\cdot}2H_2O$ 10mg, pH 3.5) and boiled at $100^{\circ}C$ for 120min in water bath. pH was adjusted to 5 with 2.3% sodium acetate. Labeling efficiency was measured using TLC-SG(acetone, saline). We evaluated biodistribution of Re-188-DTPA in sacrificed mice at 10 and 60 minutes after injection. We acquired images of kidneys, and drew time-activity curves in normal dogs and rats and calculated Tmax and Tl/2 in rats. The labelling efficiency was 95.7% on average. Labelling of Re-188-DTPA was.stable(90% after 5hours) in vitro at room temperature. According to time-activity curves of dogs and rats, it took 15 to 20 minutes after injection for Re-188-DTPA to be washed out through kidneys. In conclusion, Re-188-DTPA was successfully labeled, Re-188-DTPA was stable in vitro and was excreted early via kidneys in animals. We could recommend Re-188-DTPA as radionuclide of potential use in angioplasty balloon radiotherapy.

  • PDF

The Usefulness of Initial Arterial Base Deficit in Trauma Patients (내원 초기에 측정한 외상환자의 동맥혈 염기결핍의 유용성)

  • Lee, Eun Hun;Choi, Jae Young;Choi, Young Cheol;Hwang, Seong Youn
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The arterial base deficit (BD) has proven to be useful in the evaluation and management of trauma patients. Indicators such as the Triage-Revised Trauma Score (t-RTS) and the systemic inflammatory response syndrome (SIRS) score have been used as triage tools for emergency trauma patients in Korea. The purpose of this study was to assess the usefulness of the initial BD in predicting injury severity and outcome in the trauma population. Methods: The medical records of 308 consecutive trauma patients admitted to the Emergency Center of Masan Samsung Hospital from January 2004 to December 2004 were carefully examined prospectively and retrospectively, and 291 patients were selected as subjects for this research. The SIRS score and the t-RTS were calculated based on the records from the emergency department, and the BD was calculated based on the arterial blood gas analysis obtained within 30 minutes of admission. The efficiency of the three indicators as triage tools was evaluated by using cross tabulations in two - by - two matrices and by using a receiver operating characteristic (ROC) curve analysis. Results: When the mortality was used as the outcome parameter, the sensitivity and the accuracy of the initial BD were higher than those of the SIRS score (p<0.05) and were same as those of the t-RTS. The areas under the ROC curves of the initial BD, the SIRS score, and the t-RTS were $0.740{\pm}0.087$, $0.696{\pm}0.082$, and $0.871{\pm}0.072$, respectively (95% confidence interval). When emergency operation and blood transfusion requirements were used as outcome parameters, the comparisons of the sensitivities and the accuracies of the initial BD and the other two indicators showed the same pattern as mentioned above. The areas under the ROC curves of the initial BD were 0.7~0.8 and were larger than those of the SIRS score (p<0.05). Conclusion: The ability of the initial BD to predict injury severity and outcome was similar to those of the t-RTS and the SIRS score. Therefore, the authors suggest that the initial BD may be used as an alternative to previous triage tools for trauma patients.

Electrical Properties of SrBi$_2$$Nb_2$>$O_9$ Thin Films deposited by RF Magnetron Sputtering Method (RF 마그네트론 스퍼터링법에 의해 증착된 SrBi$_2$$Nb_2$>$O_9$ 박막의 전기적 특성에 관한 연구)

  • Zhao, Jin-Shi;Choi, Hoon-Sang;Lee, Kwan;Choi, In-Hoon
    • Korean Journal of Materials Research
    • /
    • v.11 no.4
    • /
    • pp.290-293
    • /
    • 2001
  • The SrBi$_2$Nb$_2$O$_{9}$ (SBN) thin films were deposited on p-type(100) Si substrates by rf magnetron sputtering to confirm the Possibility of Pt/SBN/Si structure for the application of nondestructive read out ferroelectric random access memory (NDRO- FRAM). The SBN thin films were deposited by co-sputtering method with Sr$_2$Nb$_2$O$_{7}$ (SNO) and Bi$_2$O$_3$ ceramic targets. The SBN thin films deposited at room temperature were annealed at $700^{\circ}C$ for 1hr in $O_2$ ambient. The structural and electrical properties of SBN with different power ratios of targets were measured by x-ray diffraction(XRD), scanning electron microscopy(SEM), capacitance-voltage(C-V), and current-voltage(I-V). The C-V curves of the SBN films showed hysteresis curves of a clockwise rotation showing ferroelectricity. When the Power ratio of the SNO/Bi$_2$O$_3$ targets was 120 W/100 W, the SBN thin films had excellent electrical properties. The memory window of SBN thin film was 1.8 V-6.3 V at applied voltage of 3 V-9 V and the leakage current density was 1.5 $\times$ 10$^{-7}$ A/$\textrm{cm}^2$ at applied voltage of 5 V The composition of SBN thin films was analysed by electron probe X-ray micro analyzer(EPMA) and the atomic ratio of Sr:Bi:Nb with pawer ratio of 120 W/100 W was 1:3:2.

  • PDF

DETERMINATIONS OF ITS ABSOLUTE DIMENSIONS AND DISTANCE BY THE ANALYSES OF LIGHT AND RADIAL-VELOCITY CURVES OF THE CONTACT BINARY - I. V417 Aquilae (접촉쌍성의 광도와 시선속도곡선의 분석에 의한 절대 물리량과 거리의 결정 -1. V417 Aquilae)

  • 이재우;김천휘;이충욱;오규동
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.73-82
    • /
    • 2004
  • New photometric and spectroscopic solutions of W-type overcontact binary V 417 Aql were obtained by solving the UBV light curves of Samec et al. (1997) and radial-velocity ones of Lu & Rucinski (1999) with the 2003 version of the Wilson-Devinney binary code. In the light curve synthesis the light of a third-body, which Qian (2003) proposed, was considered and obtained about 2.7%, 2.2%, and 0.4% for U, B, and V bandpasses, respectively. The model with third-light is better fitted to eclipse parts than that with no third-light. Absolute dimensions of V417 Aql are determined from our solution as $M_1$= 0.53 $M_{*}$, $M_2$= 1.45 $M_{*}$, $R_1$= 0.84 $R_{*}$, and $R_2$= 1.31 $M_{*}$, and the distance to it is deduced as about 216pc. Our distance is well consistent with that (204pc) derived from Rucinski & Duerbeck's (1997) relation, $M_{v}$ = $M_{v}$(log P, B-V), but is more distant than that (131$\pm$40pc) determined by the Hipparcos trigonometric parallax. The difference may result from the relatively large error of Hipparcos parallax for V 417 Aql.l.

Determination of polycyclic aromatic hydrocarbons (PAHs) in used lubricating car oils (차량용 폐윤활유에 함유된 다환 방향족 탄화수소 (PAHs)의 분석)

  • Yoo, Kwang-Sik;Jyoung, Ji-Young;Jeong, Seon-Yi;Woo, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.339-348
    • /
    • 2003
  • Determination of some PAHs in used engine oils have been carried out by extraction of the components into acetonitrile followed by GC/FID and synchronous spectrofluorimetric technique. 7 PAHs, such as acenaphthene (Ace), anthracene (Anth), benzo(a)pyrene (BaP), chrysene (Chry), phenanthrene (Phen), fluoranthene (Ft), and perlyrene (Per) in used engine oil sample were able to determine separately by synchronous spectrofluorimetry. Calibration curves for those components were linear for the concentration range of 0.4~166 ppb PAHs with the corelation factor of 0.9985~0.9999. The peak areas produced by GC/FID split ratio program were used for the calibration curves of the other 8 PAHs. Detection sensitivity of the synchronous spectrofluorimetry seems to be 100 times more sensitive than GC/FID method. The total amount of PAHs in the used engine oil were 5.5 ng/g for LNG (bus), 10.5 ng/g for LPG(taxi), 92.2 ng/g for gasoline-passenger car, and 130 ng/g for diesel trailer, respectively.

Pharmacological Characterization of Synthetic Tetrahydroisoquinoline Alkaloids, YS 51 and YS 55, on the Cardiovascular System

  • Chang, Ki-Churl;Kang, Young-Jin;Lee, Young-Soo;Chong, Won-Seog;Choi-Yun, Hey-Sook;Lee, Duck-Hyong;Ryu, Jae-Chun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.4
    • /
    • pp.461-469
    • /
    • 1998
  • Tetrahydroisoquinoline (THI) alkaloids can be considered as cyclized derivatives of simple phenylethy-lamines, and many of them, especially with 6,7-disubstitution, demonstrate relatively high affinity for catecholamines. Two -OH groups at 6 and 7 positions are supposed to be essential to exert ?${\beta}-receptor$ activities. However, it is not clear whether -OH at 6,7 substitution of THIs also shows ?${\alpha}-adrenoceptor$ activities. In the present study, we investigated whether -OH or $-OCH_3$ substitutions of 6,7 position of THIs differently affect the ?1-adrenoceptor affinity. We synthesized two 1-naphthylmethyl THI alkaloids, $1-{\beta}-naphthylmethyl-6,7-dihydroxy-1,2,3,4-tetrahydroisoquinoline$ HBr (YS 51) and $1-{\beta}-naphthylmethyl-6, 7-dimethoxy-1,2,3,4-tetrahydroisoquinoline$ HCl (YS 55), and their pharmacological actions on ?${\alpha}_1-adrenoceptor$ were compared. YS 51 and YS 55, concentration-dependently relaxed endothelium-denuded rat thoracic aorta precontracted with phenylephrine (PE, 0.1 ${\mu}M$) in which $pEC_{50}$ were $5.89{\pm}0.21$ and $5.93{\pm}0.19$, respectively. Propranolol (30 nM) did not affect the relaxation-response curves to YS 51 and YS 55. Concentration-response curves to PE were shifted to right by the pretreatment with YS 51 or YS 55. The $pA_2$ values of YS 51 and YS 55 showed $6.05{\pm}0.24$ and $5.88{\pm}0.16$, respectively. Both probes relaxed KCl (65.4 mM)-contracted aorta and inhibited $CaCl_2-induced$ contraction of PE-stimulated endothelium- denuded rat thoracic aorta in $Ca^{2+}-free$ solutions. In isolated guinea pig papillary muscle, 1 and 10 ${\mu}M$ YS 51 increased contractile force about 4- and 8- fold over the control, respectively, along with the concentration-dependent increment of cytosolic $Ca^{2+}$ ions. While, 10 ${\mu}M$ YS 55 reduced the contractile force about 50 % over the control and lowered the cytosolic $Ca^{2+}$ level, in rat brain homogenates, YS 51 and YS 55 displaced $[^3H]prazosin$ binding competitively with Ki 0.15 and 0.12 ${\mu}M$, respectively. However, both probes were ineffective on $[^3H]nitrendipine$ binding. Therefore, it is concluded that two synthetic naphthylmethyl-THI alkaloids have considerable affinity to ?1-adrenenoceptors in rat aorta and brain.

  • PDF