• Title/Summary/Keyword: P-V Characteristics

Search Result 1,906, Processing Time 0.075 seconds

Characteristics of Laser-Guided DC Discharge by Nd: YAG Laser at Low Pressure

  • Lee, Dong-Hoon;Kim, Hee-Je
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.316-321
    • /
    • 1998
  • In recent years, concern has been raised about the technique of controlling electrical breakdown by using laser in many fields. Especially, laser has attracted much attention in the Electro-Discharge Macining(EDM) because of its many merits. Therefore, this research has been performed to obtain fundamental data relevant to discharge processing by using a pulsed Nd:YAG laser. The experiments of laser-guided dc discharge by laser radiation have been carried out at low air pressure ranging from 0.2 to 20 torr. The minimum laser-guided dc discharge voltage V\ulcorner at the given pressures P and distances D between an anode and a cathode was measured. It is found that the minimum laser-guided dc discharge voltage is much lower than the natural discharge voltage V\ulcorner\ulcorner, and the values of V\ulcorner and V\ulcorner as a function of P.D has a similar tendency. The laser output energy Eout decreases with input pulse duration tp increasing, and the more the value of tp increases, the higher that of V\ulcorner is obtained because the number of photons during the discharge time N decreases with t\ulcorner increasing. There is the time lag frequently when the discharge by laser radiation is misguided under the condition of the applied voltage less than V_G.min.

  • PDF

NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN COOLING CHANNEL WITH A STAGGERED V-SHAPED RIB (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, H.K.;Kim, K.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.125-130
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration ($h/D_h$) of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth channel with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 2.5 times higher streamwise pressure drop than the latter ones. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered ones give about 2 times higher values than the latter ones with more uniform heat transfer distribution.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

New convergence scheme to improve the endurance characteristics in flash memory (새로운 Convergence 방법을 이용한 플래시 메모리의 개서 특성 개선)

  • 김한기;천종렬;이재기;유종근;박종태
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.40-43
    • /
    • 2000
  • The electrons and holes trapped in the tunneling oxide and interface-states generated in the Si/SiO$_2$ interface during program/erase (P/E) operations are known to cause reliability problems which can deteriorate the cell performance and cause the V$_{th}$ window close. This deterioration is caused by the accumulation of electrons and holes trapped in the oxide near the drain and source side after each P/E cycle. we propose three new erase schemes to improve the cell's endurance characteristics: (1)adding a Reverse soft program cycle after the source erase operation, (2)adding a detrapping cycle after the source erase operation, (3)adding a convergence cycle after the source erase operation. (3) is the most effective performance among the three erase schemes have been implemented and shown to significantly reduce the V$_{th}$ window close problem. And we are able to design the reliable periperal circuit of flash memory by using the (3).(3).

  • PDF

Electrical Properties of semiconducting $VO_2$-based Critical Temperature Sensors (반도성 $VO_2$계 급변온도센서의 전기적 특성)

  • 유광수;김종만;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.10
    • /
    • pp.866-870
    • /
    • 1993
  • For VO2-based sensors applicable to temperature measurements and optical disk materials by the nature of semiconductor to metal transition, the crystallinity and temperature vs. resistance characteristics were investigated as a function of the heat treatment temperature. The bead-type sensors were prepared through typical sensor fabrication processing and heat-treated at 40$0^{\circ}C$, 50$0^{\circ}C$, and $600^{\circ}C$, respectively, for 30 minutes in H2 gas atmosphere. As results of the temperature vs. resistance measurements, the electrical resistance in the phase transition range was decreased by 102 order for the VO2 sensor and by 103 order for the V71P11Sra18 system. It was estimated that the hysteresis, temperature vs. resistance, and current vs. voltage characteristics of the V71P11Sr18 system could be utilized for commericialization as a temperature sensor.

  • PDF

P-V Characteristics of Photovoltaic According to the Irradiation

  • Lee, Ying;Choi, Yong-Sung;Zhang, You-Sai;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2101_2102
    • /
    • 2009
  • Solar energy has inestimable development potential. However, it is an extreme intermittent and inconstant energy source. The radiative energy output from the sun derives from a nuclear fusion reaction. So it is necessary to study the photovoltaic P-V characteristics according to the irradiation. The results show that the DC power of the photovoltaic system is increased along with the increasing values of irradiation and module.

  • PDF

Seasonal Load Characteristics on 22.9[tV] Bus for Load Modeling (부하모델링을 위한 22.9[kV]모선의 계절별 부하특성에 관한 연구)

  • Ji, P.S.;Lee, J.P.;Lim, J.Y.;Kim, K.D.;Park, S.W.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.304-306
    • /
    • 2000
  • Load modeling, micro method, needs field test to identify the validity of methodology applied to modeling. This paper presents seasonal field test method and measurement results on serveral substations. Seasonal load characteristics were analyzed by the developed substation load model and correlation coefficients of seasonal load of substation under base, peak and average load time.

  • PDF

Characteristics of Sulfide Treated GaAs MISFETs with Photo-CVD Grown $P_3$$N_5$ Gate Insulators (유화처리와 광CVD법 질화인막을 이용한 GaAs MISFET 특성)

  • 최기환;조규성;정윤하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.9
    • /
    • pp.72-77
    • /
    • 1994
  • GaAs MISFETs, with photo-CVD grown P$_{3}$N$_{5}$ gate insulator and sulfide treatment, have been fabricated and showed the instability of drain current reduced less than 22 percent for the period of 1.0s~1.0${\times}10^{4}s$. The effective electron mobility and extrinsic transconductance of the device are about 1300cm$^{2}$/V.sec and 1.33mS at room temperature. The C-V characteristics of GaAs MIS Diode and AES analysis are also discussed with respect to effect of sulfide treatment conditions.

  • PDF

A Study on the Combustion Characteristics of Opposed-jet-Flames in a Divided Combustion Chamber (분할연소실내의 대향분출화염의 연소특성에 관한 연구)

  • 조경국;정인석;정경석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.50-60
    • /
    • 1987
  • Combustion characteristics of opposed-jet-flames spouting out from dual prechambers of a divided combustion chamber were investigated by using high speed schilieren photography and chamber pressure measurement. Result shows that opposed-jet-flames are characterized by the parameter ( $A_{ori}$/ $V_{p}$) and there exists a certain critical value of ( $A_{ori}$/ $V_{p}$)c which distinguishes flame propagation patterns in the main chamber. Also higher chamber pressure and shorter total burning time can be derived by adopting this dual prechamber divided combustion chamber, which would lead a possibility of an appropriate combustion method of high load and low emissions.ons.ons.

  • PDF

Quality Changes in Peeled Lotus Roots Immersed in Electrolyzed Water Prior to Wrap- and Vacuum-Packaging (전기분해수 침지처리 박피연근의 랩 및 진공포장 저장 중의 품질변화)

  • Park, Kee-Jai;Jeong, Jin-Woong;Lim, Jeong-Ho;Kim, Bum-Kun;Jeong, Seong-Won
    • Food Science and Preservation
    • /
    • v.15 no.5
    • /
    • pp.622-629
    • /
    • 2008
  • This study investigated changes in quality characteristics of wrap- and vacuum-packaged peeled lotus roots treated with strong acidic electrolyzed acid water (SAEW pH 2.58, ORP 1,128 mV, HClO 105.0 ppm) or low alkaline electrolyzed water (LAEW pH 8.56, ORP 660 mV, HClO 73.8 ppm) as immersion liquids prior to packaging and storage at 5C. Immersion of peeled lotus roots in SAEW and LAEW reduced initial microbial load by about 1 log compared to treatment with tap water (TW). Hardness differences on storage were observed. However, reduction in PPO activity by electrolyzed water was not reproducible. Changes in Hunter's color value and the color difference value ($\Delta$) of peeled lotus roots immersed in 0.5% (w/v) sodium metabisulfite (SMS) and electrolyzed water were smaller than those of roots treated with TW prior to storage. Sensory characteristics measured during storage were best-preserved in lotus roots previously immersed in 0.5% (w/v) SMS or electrolyzed water, compared to TW. Immersionin electrolyzed water and vacuum packaging preserves the quality of peeled lotus roots in terms of microbial, visual, and sensory aspects, at levels comparable to those offered by storage after treatment with 0.5% (w/v) SMS.