• Title/Summary/Keyword: P-P bonding

Search Result 887, Processing Time 0.027 seconds

A Strong Dependence of the P-P Bond Length on the Transition Metal Component in ThCr2Si2-Type Phosphides CaM2P2 (M = Fe, Ni): The Influence of d Band Position and σp* Mixing

  • Kang, Dae-Bok
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1215-1218
    • /
    • 2003
  • An analysis of the bonding situation in CaM₂P₂ (M=Fe, Ni) with ThCr₂Si₂ structure is made in terms of DOS and COOP plots. The main contributions to covalent bonding are due to M-P and P-P interactions in both compounds. Particularly, the interlayer P-P bonding by variation in the transition metal is examined in more detail. It turns out that the shorter P-P bonds in CaNi₂P₂ form as a result of the decreasing electron delocalization into ${{\sigma}_p}^*$ of P₂ due to the weaker bonding interaction between the metal d and ${{\sigma}_p}^*$ as the metal d band is falling from Fe to Ni.

The Characteristics of the Wafer Bonding between InP Wafers and $\textrm{Si}_3\textrm{N}_4$/InP (Direct Wafer Bonding법에 의한 InP 기판과 $\textrm{Si}_3\textrm{N}_4$/InP의 접합특성)

  • Kim, Seon-Un;Sin, Dong-Seok;Lee, Jeong-Yong;Choe, In-Hun
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.890-897
    • /
    • 1998
  • The direct wafer bonding between n-InP(001) wafer and the ${Si}_3N_4$(200 nm) film grown on the InP wafer by PECVD method was investigated. The surface states of InP wafer and ${Si}_3N_4$/InP which strongly depend upon the direct wafer bonding strength between them when they are brought into contact, were characterized by the contact angle measurement technique and atomic force microscopy. When InP wafer was etched by $50{\%}$ HF, contact angle was $5^{\circ}$ and RMS roughness was $1.54{\AA}$. When ${Si}_3N_4$ was etched by ammonia solution, RMS roughness was $3.11{\AA}$. The considerable amount of initial bonding strength between InP wafer and ${Si}_3N_4$/InP was observed when the two wafer was contacted after the etching process by $50{\%}$ HF and ammonia solution respectively. The bonded specimen was heat treated in $H^2$ or $N^2$, ambient at the temperature of $580^{\circ}C$-$680^{\circ}C$ for lhr. The bonding state was confirmed by SAT(Scannig Acoustic Tomography). The bonding strength was measured by shear force measurement of ${Si}_3N_4$/InP to InP wafer increased up to the same level of PECVD interface. The direct wafer bonding interface and ${Si}_3N_4$/InP PECVD interface were chracterized by TEM and AES.

  • PDF

AN EFFECT OF ND : YAG LASER ON THE BONDING STRENGTH OF COMPOSITE RESIN TO DENTIN AND PORCELAIN (Nd : YAG 레이저가 상아질 및 도재와 복합레진간의 결합강도에 미치는 영향)

  • Woo, Gum-Jin;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.385-399
    • /
    • 1997
  • The purpose of this experiment was to determine the effects of etching with a Nd : YAG Laser on dentin, or porcelain surface on the bond strength with composite resin. The dentin specimens were devided into the following 4 groups. D1 : No treatment D2 : Etched with 10% phosphoric acid D3 : Laser etchded with 1W, 20PPs D4 : Laser etched with 2W, 20PPS The procelain specimens were devided into the following 4 groups. P1 : diamond roughened P2 : etched with HF acid P3 : Laser etched with 2W, 20PPS P4 : Laser etched with 3W, 20PPS All specimens were veneered with resin. One half of the specimens were stored in $37^{\circ}C$ water for one day and the other half were thermocycled 1000 times at temperature of $5^{\circ}C\;to\;55^{\circ}C$ at 20 seconds intervals. After that, the bonding strength of composite resin to the dentin and porcelain was measured. The surface treated state and fractured state were observed with SEM. The following results were obtained. 1. In the dentin specimens, the bond strength of group D2 was highter than that of groups D1 and D3 in the case of the specimens stored in $37^{\circ}C$ water for one day, there was a statistically significant difference between group D2 and D1, D3 (P<0.05). The bonding strength of the specimens that were thermocycled decreased in the following order : group D2,D4,D3 and then D1. 2. In the porcelain specimens, the bonding strength of groups P1,P2 were higher than that of group P3 in the case of the specimens stored in $37^{\circ}C$ water for one day (P<0.05). The bonding strength of the specimens of being thermocycled decreased in the following order : group P2,P1,P4 and then P3. 3. The groups of high bond strength had a rougher surface and a high level of microporosity with SEM findings.

  • PDF

Effect of additional etching and ethanol-wet bonding on the dentin bond strength of one-step self-etch adhesives

  • Ahn, Joonghee;Jung, Kyoung-Hwa;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.68-74
    • /
    • 2015
  • Objectives: This study examined the effects of additional acid etching on the dentin bond strength of one-step self-etch adhesives with different compositions and pH. The effect of ethanol wetting on etched dentin bond strength of self-etch adhesives was also evaluated. Materials and Methods: Forty-two human permanent molars were classified into 21 groups according to the adhesive types (Clearfil SE Bond [SE, control]; G-aenial Bond [GB]; Xeno V [XV]; Beauti Bond [BB]; Adper Easy Bond [AE]; Single Bond Universal [SU]; All Bond Universal [AU]), and the dentin conditioning methods. Composite resins were placed on the dentin surfaces, and the teeth were sectioned. The microtensile bond strength was measured, and the failure mode of the fractured specimens was examined. The data were analyzed statistically using two-way ANOVA and Duncan's post hoc test. Results: In GB, XV and SE ($pH{\leq}2$), the bond strength was decreased significantly when the dentin was etched (p < 0.05). In BB, AE and SU (pH 2.4 - 2.7), additional etching did not affect the bond strength (p > 0.05). In AU (pH = 3.2), additional etching increased the bond strength significantly (p < 0.05). When adhesives were applied to the acid etched dentin with ethanol-wet bonding, the bond strength was significantly higher than that of the no ethanol-wet bonding groups, and the incidence of cohesive failure was increased. Conclusions: The effect of additional acid etching on the dentin bond strength was influenced by the pH of one-step self-etch adhesives. Ethanol wetting on etched dentin could create a stronger bonding performance of one-step self-etch adhesives for acid etched dentin.

A STUDY ON THE FORMATION OF SHEAR BONDING STRENGTH AND HYBRID LAYER ACCORDING TO THE APPLICATION TIME AND FREQUENCY OF AN ALL-IN-ONE SYSTEM IN PRIMARY TEETH. (유치에서 All-In-One system의 적용 시간과 적용 횟수에 따른 전단 결합 강도 및 혼성층 형성에 관한 연구)

  • Hong, Sang-Jin;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.263-271
    • /
    • 2003
  • The purpose of the present study was to evaluate the patterns of hybrid layer according to the application time and the frequency and its effects on the shear bonding strength of All-In-One system in primary teeth. A single bonding agent(Scotchbond Multi-Purpose Plus, 3M) and an All-In-One system(Prompt L-pop, 3M ESPE) were applied on the dentin varying the application time and the frequency in primary teeth. Shear bond strength was measured and the patterns of hybrid layers were observed by SEM. The following results were obtained ; 1. The shear bonding strength of single bonding agent was significantly higher than that of All-In-One system(P<0.05). 2. The shear bonding strength of All-In-One system applied twice or 3 times were higher than that of applied once (P<0.05). And thickness of the hybrid layer was increased when applied twice or 3 times compared to once. 3. The shear bonding strength of All-In-One system when applied for 15 second and 30 second were higher than that of 7 second (P<0.05). And the hybrid layer thickness of 15 second and 30 second's application time were higher than that of 7 second. 4. Thickness of hybrid layer applied with single bonding agent was $2-4{\mu}m$ and that of All-In-One system was $1-2{\mu}m$.

  • PDF

A Study on Characterization of P-N Junction Using Silicon Direct Bonding (실리콘 직접 본딩에 의한 P-N 접합의 특성에 관한 연구)

  • Jung, Won-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.615-624
    • /
    • 2017
  • This study investigated the various physical and electrical effects of silicon direct bonding. Direct bonding means the joining of two wafers together without an intermediate layer. If the surfaces are flat, and made clean and smooth using HF treatment to remove the native oxide layer, they can stick together when brought into contact and form a weak bond depending on the physical forces at room temperature. An IR camera and acoustic systems were used to analyze the voids and bonding conditions in an interface layer during bonding experiments. The I-V and C-V characteristics are also reported herein. The capacitance values for a range of frequencies were measured using a LCR meter. Direct wafer bonding of silicon is a simple method to fuse two wafers together; however, it is difficult to achieve perfect bonding of the two wafers. The direct bonding technology can be used for MEMS and other applications in three-dimensional integrated circuits and special devices.

Thermal Cycle Reliabilties and Cracking Characteristics of Electroplated Cr/Ni-P Coatings (전해 Cr/Ni-P 도금막의 열 사이클 신뢰성 및 균열거동 분석)

  • Lee, Jina;Son, Kirak;Lee, Kyu Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.133-140
    • /
    • 2019
  • The effects of thermal cycle conditions on the bonding strength and crack propagation behaviors in electroplated Cr/electroplated Ni-P coatings were systematically evaluated. 1st heat treatment was performed at 500℃ for 3 hours after electroplating Ni-P, and then, 2nd heat treatment was performed at 750℃ for 6 hours after electroplating Cr. The measured bonding strength by ASTM C633 were around 25.6 MPa before thermal cycling, while it increased to 47.6 MPa, after 1,000 cycles. Increasing thermal cycles led to dominant fail mode with cohesive failure inside adhesive, which seemed to be closely related to the increasing bonding strength possibly not only due to higher Cr surface roughness, but also to penetrated channeling crack density. Also, increasing density of penetrated channeling cracks in electroplating Cr layer led to slightly stronger bonding strength due to mechanical interlocking effects of adhesive inside channeling cracks.

Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic

  • Tae-Yub Kwon;Seung-Hee Han;Du-Hyeong Lee;Jin-Woo Park;Young Kyung Kim
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia. MATERIALS AND METHODS. Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test. RESULTS. The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (P < .001), the PF/CON obtained a higher SBS value than the DL/CON (P < .001) and no decrease even after thermocycling (P = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (P < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (P = .002), showing no significant decrease after thermocycling (P > .05). The initial SBS of the PF/PBU was similar to the PF/CON (P = .999), but the value decreased after thermocycling (P < .001). CONCLUSION. The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.

p-contact resistivity influence on device-reliability characteristics of GaN-based LEDs (p-contact 저항에 따른 GaN기반 LED의 device-reliability 특성)

  • Park, Min-Jung;Kim, Jin-Chul;Kim, Sei-Min;Jang, Sun-Ho;Park, Il-Kyu;Park, Si-Hyun;Cho, Yong;Jang, Ja-Soon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.159-159
    • /
    • 2010
  • We conducted bum-in test by current stress to evaluate acceleration reliability characteristics about p-resistivity influence of GaN-based light-emitting diodes. The LEDs used in this study are the polarization field-induced LED(PF-LED) having low p-resistivity and the highly resistive LED(HR-LED) having high p-resistivity. The result of high stress experiment shows that current crowding phenomenon is occurred from the center of between p-bonding pad and n-bonding pad to either electrodes. In addition, series resistance and optical power decrease dramatically. These results means that the resistance of between p-bonding pad and p-GaN affect reliability. That's why we need to consider the ohmic contact of p-bonding pad when design the high efficiency and high reliability LEDs.

  • PDF

Bonding Strength of Ozonized Soybean Oil-based Modified pMDI Adhesive Hardened at High and Medium Temperature (오존산화 콩기름 변성 pMDI 접착제의 고온 및 중온 경화 접착력)

  • Lee, Eung-Su;Kang, Chan-Young;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.541-546
    • /
    • 2010
  • This study was to investigate the dry bond strengths of the plywoods manufactured with 3 hours ozonized soybean oil (SBO)/polymeric methylene diphenyl diisocyanate (pMDI) adhesive at mid and high curing temperature. In results of the dry bonding strengths of the 3 hrs-ozonized SBO mixed with pMDI at high curing temperature were respectively the strengths of weight ratio of 3hrs-ozonized SBO : pMDI, 1 : 0.5, 4.74 kgf/$cm^2$, 1 : 0.75, 7.14 kgf/$cm^2$ 1 : 1, 9.29 kgf/$cm^2$, 1 : 2, 16.53 kgf/$cm^2$, 1 : 3, 17.42 kgf/$cm^2$, and 1 : 4, 16.75 kgf/$cm^2$. Therefore, it was found that the equivalent ratio was formed approximately between 3 hrs-ozonized SBO : pMDI 1 : 2 and 1 : 3. The dry bonding strengths of the 3hrs-ozonized SBO mixed with pMDI at medium curing temperature were respectively the strengths of weight ratio of 3 hrs-ozonized SBO : pMDI, 1 : 0.5, 3.16 kgf/$cm^2$, 1 : 0.75, 6.13 kgf/$cm^2$ 1 : 1, 8.18 kgf/$cm^2$, 1 : 2, 11.82 kgf/$cm^2$. In this experiment the higher bonding strength at high curing temperature was shown approximately between 3 hrs-ozonized SBO : pMDI 1 : 2 and 1 : 3. If this wood adhesive is used at high curing temperature, it is possibile to bond the plywoods.