• Title/Summary/Keyword: P-Method

Search Result 22,944, Processing Time 0.044 seconds

Evaluation of Validity Glomerular Filtration Rate Measured by Gates Method according Region of Interest (관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가)

  • Su-Young Park;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.417-425
    • /
    • 2023
  • The glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0~1 minutes, Gates-2: 1~3 minutes, Gates-3: 3~27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2~3 minutes is calculated can aid in accurately determining GFR when Gates Method.

Irradiation-induced Volatile Compounds in Irradiated Chicken by P&T Method (P&T법에 의한 닭고기의 방사선 유래 휘발성 조사물질 구명)

  • Kim, Hun;Cho, Woo-Jin;Jung, Yeon-Jung;Lee, Young-Mi;Jeong, Eun-Jeong;Yoo, Young-Jae;Byun, Myung-Woo;Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.6
    • /
    • pp.958-964
    • /
    • 2002
  • To select the irradiation-induced marker components from volatile flavor compounds in irradiated chicken, and complement the extraction problems of liquid continuous extraction (LLCE) method, the volatile compounds of irradiated (0,1,3,5 and 10 kGy) chicken were analyzed by Purge and Trap (P&T) and gas chromatography/mass spectrometry (GC/MS) methods. A total of 119 compounds were detected in irradiated chicken, and these compounds were composed mainly of 7 aldehydes,22 ketones,8 alcohols,30 esters,36 hydrocarbons,8 aromatic compounds and 8 miscellaneous compounds. Among these, only 21 compounds were detected in both LLCE and P&T methods, and the 98 other were detected in omly P&T method. Among volatile compounds detected in irradiated chicken, only 3 compounds such as hexene (r=0.96, p<0.01), propanol (r=0.93, p<0.05) and 1,3-bis(1,1-dimethylethyl) benzene (r=0.96, p<0.05) were newly selected as marker compounds in irradiated chicken by P&T method, which showed significant and high positive correlation coefficient in the change of relative concentration according to the increment of irradiation dosage.

Improving Method of Pre-treatment for Detection Benzo($a$)pyrene Contents in Concentrates (농축물의 Benzo($a$)pyrene 함량 측정을 위한 전처리 방법의 개선)

  • Koo, Bon-Soon
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.4
    • /
    • pp.797-802
    • /
    • 2011
  • I assessed the B($a$)P content from the Ginseng extract, Red ginseng extract, and Ssangwha extract which have high viscosities. It wasn't easy to extract oil from these samples, consequently measuring of B($a$)P was difficult. In order to know the exact detecting contents, I injected standard material of B($a$)P to the above extractions and pre-treated for measurement but it was also difficult to measure of contents exactly. To improve of detecting method, I removed mucinous materials using a 85% phosphoric acid solution or 10% citric acid solution and then processed continuously with $60^{\circ}C$ hot water. The analysis revealed that extracting the samples contained B($a$)P determined the rate of each 70%, 55%, 67% could increase. As a result the detecting method of B($a$)P contents could be improved.

ON THE DISTANCE TO A ROOT OF COMPLEX POLYNOMIALS UNDER NEWTON'S METHOD

  • Chaiya, Malinee;Chaiya, Somjate
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.5
    • /
    • pp.1119-1133
    • /
    • 2020
  • In this paper, we derive an upper bound for the distance from a point in the immediate basin of a root of a complex polynomial to the root itself. We establish that if z is a point in the immediate basin of a root α of a polynomial p of degree d ≥ 12, then ${\mid}z-{\alpha}{\mid}{\leq}{\frac{3}{\sqrt{d}}\(6{\sqrt{310}}/35\)^d{\mid}N_p(z)-z{\mid}$, where Np is the Newton map induced by p. This bound leads to a new bound of the expected total number of iterations of Newton's method required to reach all roots of every polynomial p within a given precision, where p is normalized so that its roots are in the unit disk.

Improved Mid P-value Method for Statistical Inference in Three-Way Contingency Tables

  • Donguk Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.3
    • /
    • pp.905-926
    • /
    • 1998
  • We propose a modified mid P-value method to reduce the conservativeness for the inference of conditional associations in three-way contingency tables. This improves the ordinary mfd P-value method. For $2{\times} 2${\times} K$ tables, we propose confidence intervals for an assumed common odds ratio based on inverting two separate one-sided tests using the modified mid P-value. Also, an alternative and usually even better ways of constructing intervals, based on Inverting a two-sided test, are presented. The actual probability of coverage of a 100($1-\alpha$)% confidence interval is centered about the nominal level, but the modified mid P-value approach gives actual coverage probability even closer to the nominal level than the ordinary mid P-value approach.

  • PDF

Computation method of effective bandwidth of VBR MPEG video traffic using the modified equivalent capacity (수정된 equivalent capcity를 이용한 VBR MPEG 비디오 트랙픽의 등가대역폭 계산방법)

  • 하경봉;이창범;박래홍
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.10
    • /
    • pp.40-47
    • /
    • 1996
  • A method for computing effectiv ebandwidth of aggregated varable bit rate (VBR) moving picture experts group (MPEG) video traffic is proposed. To compute statistical characteristics of aggregated MPEG traffic, first we split input MPEG traffic into I, B, and P frame traffics and aggregate respective I, B, and P frame traffics according to the frame type. Second statisticsal characteristics of the aggregated MPEG traffic are obtained using those of aggregated I, B, and P frame traffics. The effective bandwidth of the aggregated I frame traffic is computed by using the gaussian bound. Using the modified equivalent capacity, we obtain the effective bandwidths of aggregated B and P frame traffics and then compute the effective bandwidth of the combined B and P frame traffic. Finally the effective bandwidth of the aggregated MPEG traffic is computed by adding the gaussian bound of the aggregated I frame traffic and modifed equivalent capacity of combined B and P frame traffic. Computer simulation shows that the proposed method estimates effective bandwidth of the aggregated MPEG traffic well.

  • PDF

Processes For Fabricating Planar p-n Diodes and Planar n-p-n Transistors (푸래너.다이오드와 트랜지스터의 시작[제I보])

  • Jeong, Man-Yeong;An, Byeong-Seong;Kim, Jun-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.2
    • /
    • pp.2-9
    • /
    • 1966
  • fabricating processes of silicon planar n-p-n transistors are described. These processes include materical preparation, oxidation, photoresist, boron diffusion, phosphorous diffusion, and aluminium metalizing. Boron layer has been diffused in n type silicon from B2O3-SiO2 source using the box method, Phosporous layer has been diffused from P2O5-SiO2 source with the same method. The planar diodes are also fabricated by the processes described above.

  • PDF

Determination of Parathion Metabolite, p-Nitrophenol in Urine of Parathion Factory Workers

  • Han, Don-Hee;Jung, Dong-Gyun;Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.985-987
    • /
    • 2008
  • Parathion is an organophosphate pesticide being legally applied for the purpose of agriculture and is being manufactured in Korea. A gas chromatography/mass spectrometric method was developed for the determination of parathion urinary metabolite, p-nitrophenol. p-Nitrophenol was extracted from weak acidic urine, and then measured by gas chromatography-mass spectrometry (selected ion monitoring). The recovery of pnitrophenol in the overall procedure was 88.2%. The detection limit of the assay was 1.0 $\mu$ g/L based upon assayed urine of 2.0 mL. The method was applied to the determination of p-nitrophenol in urine of workers of a parathion industry. Spot urines of workers of a parathion industry were sampled at the end of shift and pnitrophenol was analyzed using above developed method. p-Nitrophenol could be detected in all of the urine samples at concentrations varying from 3.0 to 681 $\mu$ g/L.

ONE-DIMENSIONAL JUMPING PROBLEM INVOLVING p-LAPLACIAN

  • Jung, Tacksun;Choi, Q-Heing
    • Korean Journal of Mathematics
    • /
    • v.26 no.4
    • /
    • pp.683-700
    • /
    • 2018
  • We get one theorem which shows existence of solutions for one-dimensional jumping problem involving p-Laplacian and Dirichlet boundary condition. This theorem is that there exists at least one solution when nonlinearities crossing finite number of eigenvalues, exactly one solutions and no solution depending on the source term. We obtain these results by the eigenvalues and the corresponding normalized eigenfunctions of the p-Laplacian eigenvalue problem when 1 < p < ${\infty}$, variational reduction method and Leray-Schauder degree theory when $2{\leq}$ p < ${\infty}$.

Recovery of Plant Cell and Its Debris by pH Control (pH 조절에 의한 식물세포 및 세포조각 회수)

  • 김진현
    • KSBB Journal
    • /
    • v.15 no.4
    • /
    • pp.405-407
    • /
    • 2000
  • A novel recovery method was developed to obtain the plant cell and its debris from Taxus chinensis cell cultures By pH control of plant cell cultures plant cell and debris was precipitated. The best pH is between 1.8 and 2.2 to obtain the precipitate of the plant cell and debris. Also paclitaxel is stable in this acidic conditions. This method is very simple an efficient to recover the plant cell and debris from plant cell cultures.

  • PDF