• Title/Summary/Keyword: P-I curve

Search Result 303, Processing Time 0.025 seconds

Improved Arithmetic in Optimal Extension Fields with Application in Elliptic Curve Cryptography (타원곡선 암호 응용을 위한 개선된 최적확장체 연산)

  • Lee Mun-Kyu
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.187-189
    • /
    • 2005
  • 최적확장체(Optimal Extension Field:OEF)는 유한체의 일종으로서, 타원곡선 암호시스템의 소프트웨어 구현에 있어 매우 유용하다. Bailey및 Paar는 $p^i$거듭제곱 연산을 비롯하여 다수의 효율적인 OEF연산 알고리즘을 제안하였으며, 또한 암호 응용에 적합한 OEF를 생성하기 위한 효과적인 알고리즘을 제안하였다. 본 논문에서는 Bailey-Paar의 $p^i$거듭제곱 알고리즘이 적용되지 않는 반례를 제시하며, 또한 그들의 OEF생성 알고리즘은 실제로 OEF가 아닌 유한체를 OEF로 출력하는 오류가 있음을 보인다. 본 논문에서는 이러한 문제들을 해결한 개선된 알고리즘들을 제시하고, OEF의 개수에 관한 수정된 통계치를 제시한다.

  • PDF

Silicon thin film and p-n junction diode made by $CO_2$ laser-induced CVD method ($CO_2$ Laser-induced CVD법에 의한 Silicon박막 및 p-n 접합 Silicon제작)

  • Choi, H.K.;Jeong, K.;Kim, U.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.662-666
    • /
    • 1989
  • Pure mono Silane(Purity: 99.99%) was used as a thin film source and [$SiH_4$ + $H_2$ (5%)] + [$PH_3$ + $H_2$(0.05%)] mixed dilute gas was used for p-n junction diode. The substrate was P-type silicon wafer (p=$3{\Omega}$ cm) with the direction (100). The crystalline qualities of deposited thin film were investigated by the X-ray diffraction, RHEED and TED patterns and the voltampere characteristics of p-n junction diode was identified by I-V curve.

  • PDF

Posture and Low Back Pain (일반적인 자세가 요통에 미치는 영향에 대한 고찰)

  • Jung, Mun-Boung;Lee, Geoun-Sung;Kang, Eun-Mi;Oh, Kyeong-Seok
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.4
    • /
    • pp.207-214
    • /
    • 1996
  • Main cause of low back pain is a poor posture. Most low back pains are due to a poor posture. The poor posture induces muscle tension and finaliy low back pain. The poor posture arehabitually trained from the childhood by the environmetal factors. In general, maintaining good posture during working and sleeping hours are the first line of defence against back pam. (1) Supine posture is the easiest posture that relaxes and fixes muscles. Supine posture is thus a starting position for on exercise. Lying down releases the weight pressures of head and shoulder and thus body can be relaxed and extended which are helpful for treating back pain. However, supine posture can increase the pressure in ribcage posture aspect and disphragram due to visceral oragans. (2) Sitting in one position for a long time results in fatigue and relaxation of spinal muscies. Finally, body strength is weakened and sitting posture will become poor. If this poor posture continues for a longer time, pain will be accompanied due to overelongation of muscle ligaments. The habitual poor posture could induce intervertebral disc distortion. If the intervertebral disc is damaged, sitting in one position or movement causes pain. (3) Abnormal lumbar curve induces the tention of abdominal muscle and paravertebral muscle groups as well as tention of lower limb muscle group connected to pelvis. For a person with weak body strength, muscle relaxation increases curvature in lumbar, chest and cervical regions. This will induce a pelvic anterior tilting of the imaginary line between A. S. I. S. and P. S. I. S. Hip joint extensor muscle acts on releasing the pelvic anterior tilting. Contrections of hamstring muscle and femoral muscle recover the imaginary line between A.S.LS. and P.S.I.S. from pelvic anterior tilting. thus, contraction of rectus abdominis muscle are required to maintain the normal lumbar curve.

  • PDF

PLASMA POLYMERIZED THIN FILMS GROWN BY PECVD METHOD AND COMPARISON OF THEIR ELECTROCHEMICAL PROPERTIES

  • I.S. Bae;S.H. Cho;Park, Z. T.;Kim, J.G.;B. Y. Hong;J.H. Boo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.119-119
    • /
    • 2003
  • Plasma polymerized organic thin films were deposited on Si(100) glass and Copper substrates at 25 ∼ 100 $^{\circ}C$ using cyclohexane and ethylcyclohexane precursors by PECVD method. In order to compare physical and electrochemical properties of the as-grown thin films, the effects of the RF plasma power in the range of 20∼50 W and deposition temperature on both corrosion protection efficiency and physical properties were studied. We found that the corrosion protection efficiency (P$\_$k/), which is one of the important factors for corrosion protection in the interlayer dielectrics of microelectronic devices application, was increased with increasing RF power. The highest P$\_$k/ value of plasma polymerized ethylcyclohexane film (92.1% at 50 W) was higher than that of the plasma polymerized cyclohexane film (85.26% at 50 W), indicating inhibition of oxygen reduction. Impedance analyzer was utilized for the determination of I-V curve for leakage current density and C-V for dielectric constants. To obtain C-V curve, we used a MIM structure of metal(Al)-insulator(plasma polymerized thin film)-metal(Pt) structure. Al as the electrode was evaporated on the ethylcyclohexane films that grew on Pt coated silicon substrates, and the dielectric constants of the as-grown films were then calculated from C-V data measured at 1㎒. From the electrical property measurements such as I-V ana C-V characteristics, the minimum dielectric constant and the best leakage current of ethylcyclohexane thin films were obtained to be about 3.11 and 5 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$ and cyclohexane thin films were obtained to be about 2.3 and 8 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$.

  • PDF

Purification and Properties of Protein Methylase I from Hog Pancreas (돼지 췌장내 Protein Methylase I의 분리정제 및 성질)

  • 이향우;장만식
    • YAKHAK HOEJI
    • /
    • v.31 no.3
    • /
    • pp.173-181
    • /
    • 1987
  • Protein methylase I has been partially purified from hog pancreas with a 11% yeild. The final preparation is completely free of any other protein-specific methyltransferases and endogenous substrate proteins. The enzyme has an optimum pH of 7.2 and the approximate molecular weight is above 800 thousands dalton. The Km values for S-adenosyl-L-methionine and histone type II-A are 1.32$\times$10$^{-5}$M. The Ki value for S-adenosyl-L-homocysteine is 1.52$\times$10$^{-6}$M. The effect of enyzme concentration on the activity showed a slight sigmoidal curve suggesting the involvement of certain cofactors. Even though the purified enzyme showed two bands on polyacrylamide gel electrophoresis, the enzyme is highly specific for the arginine residues of protein and specifically, highly specific for histone, suggesting histonespecific protein methylase I.

  • PDF

대관령 가축시험장 지양에 있어서의 몇 개의 방목지에 대한 생태학적 연구

  • 박봉규
    • Journal of Plant Biology
    • /
    • v.5 no.3
    • /
    • pp.1-4
    • /
    • 1962
  • A district (Sae-Bong) and 13 district (Sae-Jang Dong) grassland could be divided into four type of Community: Miscanthus-Community, Glyceria-Community, Festuca-Community, and Plantago-Community. Chose 17 or 20 stands from each district A and B and calculated F.I. with the Curtis method, finally vegetational continuum could be recognized while discontinuous boundary line of species distribution could not be recognized. As a rule the distributional curve of species was binominal or bell shaped. It had a distribution pattern peculiar to itself. As to the relationship of cattles' density and vegetation. I found that the tendency of F.I. moving from small to large paralleled that of disturbance-pressure from weak to strong. Found that the more the steepness of environmental factors be controlled by a rule " from large to small", the more F.I. might be controlled by a rule "from small to large" and that pH, soil-moisture-content, loss on ignition was in relation with the steepness. with the steepness.

  • PDF

Electrical Properties of p-GaAs Photoelectrode for Solar Energy Conversion (태양광 변환을 위한 p형 GaAs 광전극의 전기적 특성)

  • 윤기현;이정원;강동헌
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.11
    • /
    • pp.1262-1268
    • /
    • 1995
  • Photoelectrochemical properties of p-GaAs electrode have been investigated. I-V characteristic shows that the cathodic photocurrent is observed at -0.7 V vs. SCE. The photoresponse at near 870~880nm wavelength indicates that the photogenerated carriers contibuted to the observed current. The maximum converson efficiency of 35% is obtained for a Xe lamp light source at 400nm. In C-V relation, capacitance peaks appeared at the frequencies of 100Hz and 300Hz due to the activation of the interfacial states which exist at the energy level corresponding to the one-third of the GaAs band gap. The difference of about 1.1V between flatband potential (Vfb) from the Mott-Schottky method and onset voltage from I-V curve is observed due to the trap of carriers at the interfacial states in the boundary between GaAs and electrolyte. In case of WO3 deposited p-GaAs electrode, higher positive onset current and photocurent density are obtained. This can be explained by the fact that carriers are generated by light penetrated into the WO3 thin flm as well as p-GaAs substrate and then move into the electrolyte effectively.

  • PDF

Water Quality Management Measures for TMDL Unit Watershed Using Load Duration Curve (수질오염총량 단위유역별 LDC(Load Duration Curve, 부하지속곡선) 적용을 통한 수질관리 대안 모색 - 금호강 유역 대상)

  • Yun, Soyoung;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • This study was to develop effective water quality management measures using LDC (Load Duration Curve) curves for TMDL (Total Maximum Daily Loads) unit watershed. Using LDC curves, major factors for BOD and T-P concentration loads generation (i.e. point source or non-point source) in the case study area (Geumho river basin) were found for different hydrologic conditions. Different measures to deal with the pollutant loads were suggested to establish BMPs (Best Management Practices). It was found that the target area has urgent T-P management methods especially at moist and midrange hydrologic conditions because of point source pollutants occurred in developed areas. One example measure for this could be establishment of advanced treatment facility. This study proved that the use of LDC was a useful way to achieve TWQ (Target Water Quality) on the target watershed considered. It was also expected that the methodology applied in this study could have a wider application on the establishment of watershed water management measures.

Ductile Fracture Behaviour of SA 533B Pressure Vessel Steel Under Mixed Mode (I/II) Loading (혼합 모드(I/II) 하중에 의한 SA533B 압력용기강의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1829-1834
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bonding tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, the fractographic examination of fracture surfaces was carried out to compare with those of pure Mode I and Mode II. In conclusions, the J-R curves under Mixed Mode (I/II) loading were located between those of Mode I and Mode II loadings. When the mixture ratio of mixed mode (I/II) loading was high, the J-R currie of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixture ratio was low, the J-R curve looked after that of pure mode II loading. The fractographic evidences such as the shape of dimples under different loading conditions supported these conclusions.

Usefulness of presepsin in predicting the prognosis of patients with sepsis or septic shock: a retrospective cohort study

  • Koh, Jeong Suk;Kim, Yoon Joo;Kang, Da Hyun;Lee, Jeong Eun;Lee, Song-I
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.4
    • /
    • pp.318-325
    • /
    • 2021
  • Background: The diagnosis and prediction of prognosis are important in patients with sepsis, and presepsin is helpful. In this study, we aimed to examine the usefulness of presepsin in predicting the prognosis of sepsis in Korea. Methods: Patients diagnosed with sepsis according to the sepsis-3 criteria were recruited into the study and classified into surviving and non-surviving groups based on in-hospital mortality. A total of 153 patients (32 and 121 patients with sepsis and septic shock, respectively) were included from July 2019 to August 2020. Results: Among the 153 patients with sepsis, 91 and 62 were in the survivor and non-survivor groups, respectively. Presepsin (p=0.004) and lactate (p=0.003) levels and the sequential organ failure assessment (SOFA) score (p<0.001) were higher in the non-survivor group. Receiver operating characteristic curve analysis revealed poor performances of presepsin and lactate in predicting the prognosis of sepsis (presepsin: area under the curve [AUC]=0.656, p=0.001; lactate: AUC=0.646, p=0.003). The SOFA score showed the best performance, with the highest AUC value (AUC=0.751, p<0.001). The prognostic cutoff point for presepsin was 1,176 pg/mL. Presepsin levels higher than 1,176 pg/mL (odds ratio [OR], 3.352; p<0.001), higher lactate levels (OR, 1.203; p=0.003), and higher SOFA score (OR, 1.249; p<0.001) were risk factors for in-hospital mortality. Conclusion: Presepsin levels were higher in non-survivors than in survivors. Thus, presepsin may be a valuable biomarker in predicting the prognosis of sepsis.