• Title/Summary/Keyword: P-Grid

Search Result 383, Processing Time 0.031 seconds

A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters (단상 계통연계 인버터를 위한 새로운 고조파 보상법)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

An Improved Harmonic Compensation Method for a Single-Phase Grid Connected Inverter (단상 계통연계 인버터를 위한 개선된 고조파 보상법)

  • Khan, Reyyan Ahmad;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.215-227
    • /
    • 2019
  • Grid-connected inverters should satisfy a certain level of total harmonic distortion (THD) to meet harmonics standards, such as IEEE 519 and P1547. The output quality of an inverter is typically degraded due to grid voltage harmonics, dead time effects, and the device's turn-on/turn-off delay, which all contribute to increasing the THD value of the output. The use of a harmonic controller is essential to meet the required THD value for inverter output under a distorted grid condition. In this study, an improved feedforward harmonic compensation method is proposed to effectively eliminate low-order harmonics in the inverter current to the grid. In the proposed method, harmonic components are directly compensated through feedforward terms generated by the proportional resonant controller with the grid current in a stationary frame. The proposed method is simple to implement but powerful in eliminating harmonics from the output. The effectiveness of the proposed method is verified through simulation using PSIM software and experiments with a 5 kW single-phase grid-connected inverter.

Systems for Production of Calves from Hanwoo(Korean Cattle) IVM/IVF/IVC Blastocyst II. Simple, Efficient and Successful Vitrification of Hanwoo Blastocyst (체외생산된 한우 배반포기배로부터 송아지 생산을 위한 체계 II. 한우 배반포기배를 간편하면서 효율적이고 성공적으로 유리화 동결하는 방법)

  • Kim, E.Y.;Kim, D.I.;Park, N.H.;Weon, Y.S.;Nam, H.K.;Lee, K.S.;Park, S.Y.;Yoon, S.H.;Park, S.P.;Chung, K.S.;Lim, J.H.
    • Korean Journal of Animal Reproduction
    • /
    • v.23 no.4
    • /
    • pp.281-291
    • /
    • 1999
  • The objective of this study was to optimize the freezing/thawing method of in vitro produced Hanwoo blastocysts. Day 7 blastocysts after IVF were vitrified using EFS40 (40% ethylene glycol, 18% ficoll, 0.3 M sucrose and 10% FBS added m-DPBS) as a freezing solution and electron microscope (EM) grid (V-G) or straw (V-S) as an embryo container. In both method, freezing/thawing were treated by 2-step, treatment time was required in V-G method and V-S method, for 2 min / 3 min and 3.5 min / 10 min, respectively. Embryo survival was assessed as re-expanded and hatched rates at 24 h and 48 h after warming, respectively. The results obtained in these experiments were summarized as follows: when the effect of exposure in vitrification solution and chilling injury from freezing procedure on in vitro produced expanded blastocysts were examined, at 24 h after warming, embryo survival in exposure group (100.0%) was not different compared to that in control group (100.0%), although those results were significantly different with two vitrified groups (V-G: 87.8, V-S: 77.8%) (P<0.001). However, at 48 h after warming, hatched rates of V-G group (67.8%) were significantly higher than those of V-S group (53.3%) (P<0.05). In addition, this hatched rate in V-G group was not different with that in exposure group (73.3%). When the effects of embryo developmental stage (early, expanded and early hatching blastocysts) and embryo container (EM grid and straw) to the in vitro survival of vitrified-warmed day 7 Hanwoo blastocysts were simultaneously examined, fast developed embryos were indicated the better resistance to freezing than delayed developed one, irrespective of embryo containers (early; 57.1 & 24.4%, expanded; 84.7 & 60.6%, early hatching; 91.7 & 80.0%) (P<0.001). Especially, in expanded and early hatching blastocysts, embryo survival of V-G group (67.8, 95.0%) was significantly higher than those of V-S group (53.0, 65.0%) at 48 h post warming, respectively (P<0.05, P<0.001). Therefore, this study indicates that Hanwoo blastocysts can be cryopreserved more simple, efficient and successful by vitrification method using EM grid.

  • PDF

Effects of various freezing containers for vitrification freezing on mouse oogenesis

  • Kim, Ji Chul;Kim, Jae Myeoung;Seo, Byoung Boo
    • Journal of Animal Science and Technology
    • /
    • v.58 no.3
    • /
    • pp.13.1-13.7
    • /
    • 2016
  • Background: In the present study, various freezing containers were tested for mouse embryos of respective developmental stages; embryos were vitrified and then their survival rate and developmental rate were monitored. Mouse two cell, 8 cell, and blastula stage embryos underwent vitrification freezing-thawing and then their recovery rate, survival rate, development rate, and hatching rate were investigated. Methods: EM-grid, OPS, and cryo-loop were utilized for vitrification freezing-thawing of mouse embryos. Results: It was found that recovery rate and survival rate were higher in the group of cryo-loop compared to those of EM-grid (p < 0.05). Embryonic development rate, two cell embryos to blastocyst, as well as hatching rate were higher in the control group compared to the EM-grid group and OPS group (p < 0.05), yet no difference was noted between the control group and cryo-loop group. Development rate and hatching rate of eight cell morulae and blastocysts were all lower in the treatment groups than the control group whilst hatching rate of blastocysts was higher in the control group compared to the groups of EM-grid and OPS (p < 0.05); although the cryo-loop group was shown to be slightly higher than other groups, it was not statistically significant. Conclusions: In the study, we investigate effects of freezing containers on vitrified embryos of respective developmental stages; it was demonstrated that higher developmental rate was shown in more progressed (or developed) embryos with more blastomeres. There was however, no difference in embryonic development rate was shown amongst containers. Taken together, further additional studies are warranted with regards to 1) manipulation techniques of embryos for various vitrification freezing containers and 2) preventive measures against contamination via liquid nitrogen.

A Study on Radiated and Conducted Noise for Small Electrical Energy Storage System due to Its Operating State (소형 전기에너지저장장치 운전조건에 따른 방사 및 전도 방해에 관한 연구)

  • Jung, Jeong-Il;Ahn, Gun-Hyun;Kim, Young-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.18-22
    • /
    • 2015
  • When using a secondary battery in energy storage units, if the grid is in light duty the active power is stored so it can be used when the grid is in heavy duty. This makes possible for the load equalize and make the grid optimized. Recently the government is trying to propagate this technology. Depending on its capacity this kind of electric energy storage unit is used in adjusting the frequency, break up the energy peak in summer and winter, stabilize the energy output of renewable energy which can change unstably because of the environment. Which makes it possible to stabilize the grid. It is anticipated that market of 120 trillion won will be developed worldwide in 2030. Currently in Korea a steady supply is in progress. However because of stray electromagnetic waves some other electronics are malfunctioning. This paper covers the research in the method to detect the emission noise in small electric energy storage units using lithium secondary batteries and battery management system, Power conditioning systems with CIPSR standards. And the research of a more efficient method to measure such stray electromagnetic waves.

Numerical Analysis of Viscous Flows on Unstructured Grids Using the Optimal Method of Strongly Implicit Procedure (비정렬 격자계에서 S.I.P. 최적화 방법을 이용한 점성유동 수치해석)

  • Shin, Young-Seop
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.2
    • /
    • pp.196-202
    • /
    • 2012
  • In this study, numerical analysis of viscous flows is carried out based on the unstructured grid. There exist some difficulties in expressing and computing numerical derivatives on the unstructured grid due to lack of the structured characteristics. The general computer algorithms are developed to perform numerical derivatives easily and extended to be applicable to various geometries composed of hybrid meshes. And the optimal method of strongly implicit procedure is newly contrived to accelerate the rate of convergence in solving the pressure Poisson equation. To verify numerical schemes, the driven cavity problems of 2 and 3 dimension are simulated. The numerical results are compared with others and our numerical schemes are shown to be valid.

Solar Comparative Analysis of Various MPPT Algorithms (태양광 최대전력추종 제어알고리즘 성능 비교 분석)

  • Shim, Jae-Hwe;Kang, San;Kim, Shin-Ah;Hong, Ki-Nam;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.77-78
    • /
    • 2010
  • As the maximum power operating point(MPOP) of photovoltaic(PV) power systems alters with changing atmospheric conditions, the efficiency of maximum power point tracking(MPPT) is important in PV power systems. Moreover, grid-connected PV system occurs some problems such as voltage inequality and harmonics. Therefore, this paper presents the results of a grid-connected PV system modeling by PSIM simulator and investigates the influence on the grid-connected PV system from aspect of power quality, i.e. voltage drop. This paper includes four MPPT algorithms; Perturbation & Observation(P&O), Improved P&O, Increment Conductance(Incond), Hysterisis simulated with irradiation changing.

  • PDF

Efficient Flooding Algorithm for Mobile P2P Systems using Super Peer (슈퍼피어를 이용한 모바일 P2P시스템을 위한 효율적인 플러딩 알고리즘)

  • Kang, So-Young;Lee, Kwang-Jo;Yang, Sung-Bong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.2
    • /
    • pp.217-221
    • /
    • 2010
  • As the appearances of various new mobile devices and the explosive growth of mobile device users, many researches related to mobile P2P systems have been proceeded actively. In this paper, we propose a new search algorithm for the double-layered super peer system in the mobile environment. For the proposed search algorithm, we divide the entire experiment region into a grid of cells, each of which has the same size. The grid is configured properly by considering the communication range of a mobile device and the number of peers in the system. The proposed search algorithm is a partial flooding search method based on the directions of cells involved with the search. It reduces successfully the network traffic, but shows a low search hit ratio. To enhance the search hit ratio, we introduce a bridge-peer table for a super peer and utilize an n-way search. The experimental results show that the proposed algorithm made an average of 20~30% reduction in the number of message packets over the double-layered system. The success ratio was also improved about 2~5% over the double-layered system.

Modeling Implied Volatility Surfaces Using Two-dimensional Cubic Spline with Estimated Grid Points

  • Yang, Seung-Ho;Lee, Jae-wook;Han, Gyu-Sik
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.4
    • /
    • pp.323-338
    • /
    • 2010
  • In this paper, we introduce the implied volatility from Black-Scholes model and suggest a model for constructing implied volatility surfaces by using the two-dimensional cubic (bi-cubic) spline. In order to utilize a spline method, we acquire grid (knot) points. To this end, we first extract implied volatility curves weighted by trading contracts from market option data and calculate grid points from the extracted curves. At this time, we consider several conditions to avoid arbitrage opportunity. Then, we establish an implied volatility surface, making use of the two-dimensional cubic spline method with previously estimated grid points. The method is shown to satisfy several properties of the implied volatility surface (smile, skew, and flattening) as well as avoid the arbitrage opportunity caused by simple match with market data. To show the merits of our proposed method, we conduct simulations on market data of S&P500 index European options with reasonable and acceptable results.

The MPPT Control of a Small Wind Power Generation System by Adjusting the DC-Link Voltage of a Grid-connected Inverter (계통 연계형 인버터의 DC-Link 전압 가변을 통한 소형 풍력발전 시스템의 MPPT 제어)

  • Park, Min-Gi;Lee, Joon-Min;Hong, Ju-Hoon;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1402-1411
    • /
    • 2014
  • In this paper, the Maximum Power Point Tracking(MPPT) control of the small scale wind power generation system with a three-phase diode rectifier and the grid-connected inverter is studied. Without the need for the converter circuits to control speed of the generator, it is economical and the structure is simple. Compared with existing systems, it can be to reduce the power semiconductor switches and passive elements, and to implement the MPPT control with only DC-Link voltage control of the grid-connected inverter. In order to allow MPPT control without the characteristic information of the wind turbine, the P&O algorithm is applied, and these are verified by the simulation and experiment.