• Title/Summary/Keyword: P-C-T curve

Search Result 142, Processing Time 0.032 seconds

A Combined Random Scalar Multiplication Algorithm Resistant to Power Analysis on Elliptic Curves (전력분석 공격에 대응하는 타원곡선 상의 결합 난수 스칼라 곱셈 알고리즘)

  • Jung, Seok Won
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.2
    • /
    • pp.25-29
    • /
    • 2020
  • The elliptic curve crypto-algorithm is widely used in authentication for IoT environment, since it has small key size and low communication overhead compare to the RSA public key algorithm. If the scalar multiplication, a core operation of the elliptic curve crypto-algorithm, is not implemented securely, attackers can find the secret key to use simple power analysis or differential power analysis. In this paper, an elliptic curve scalar multiplication algorithm using a randomized scalar and an elliptic curve point blinding is suggested. It is resistant to power analysis but does not significantly reduce efficiency. Given a random r and an elliptic curve random point R, the elliptic scalar multiplication kP = u(P+R)-vR is calculated by using the regular variant Shamir's double ladder algorithm, where l+20-bit u≡rn+k(modn) and v≡rn-k(modn) using 2lP=∓cP for the case of the order n=2l±c.

Development of Image Post-processing System for the Cerebral Perfusion Information Mapping of MR Image (MR영상의 뇌관류 정보 Mapping을 위한 영상후처리 시스템개발)

  • 이상민;강경훈;장두봉;김광열;김영일;신태민
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • This paper works on development of an algorithm for mapping of cerebral perfusion parameters using the gamma-variate curve fitting. The signal intensity variate curve according to time measured in each pixel of perfusion MRI is nonlinear, and various hemodynamic parameters are not computed accurately. Levenberg-Marquardt algorithm(LMA), nonlinear optimum algorithm with high convergent speed and stability, is used to compute them. That is, the signal intensity variate curve is fitted by the gamma-variate function. Various hemodynamic parameters - Cerebral Blood Volume(C.B.V), Mean Transit Time(M.T.T), Cerebral Blood Flow(C.B.F), Time-to-Peak(T.T.P), Bolus Arrival Time(B.A.T), Maximum Slope(M.S) - are computed using LMA.

  • PDF

A New Measure of Process Capability for Non-Normal Process : $C_{psk}$ (비정규 공정에 대한 공정능력의 새로운 측도: $C_{psk}$)

  • 김홍준;송서일
    • Journal of Korean Society for Quality Management
    • /
    • v.26 no.1
    • /
    • pp.48-60
    • /
    • 1998
  • This paper proposes a fourth generation index $C_{psk}$, constructed from $C_{psk}$, by introducing the factor|$\mu$-T| in the numerator as an extra penalty for the departure of the process mean from the preassigned target value T. The motivation behind the introduction of $C_{psk}$ is that when $T\neqM$ process shifts away from target are evaluated without respect to direction. All indices that are now in use assume normally distributed data, and any use of the indices on non-normal data results in inaccurate capability measurements. In this paper, a new process capability index $C_{psk}$ is introduced for non-normal process. The Pearson curve and the Johnson curve are selected for capability index calculation and data modeling the normal-based index $C_{psk}$ is used as the model for non-normal process. A significant result of this research find that the ranking of the six indices, $C_{p}$, $C_{pk}$, $C_{pm}$, ${C^*}_{psk}$, $C_{pmk}$, $C_{psk}$in terms of sensitivity to departure of the process median from the target value from the most sensitive one up to the least sensitive are $C_{psk}$, $C_{pmk}$, ${C^*}_{psk}$,$C_{pm}$, $C_{pk}$, $C_{p}$.

  • PDF

Measure and Assessment of Process Capability for Nonnormal Process Data (비정규 공정 데이터에 대한 공정능력의 측도 및 평가)

  • Kim, Hong-Jun;Song, Suh-Ill
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.594-609
    • /
    • 1998
  • In this dissertation, a new process capability index $C_{psk}$ is introduced for non-normal process. The Pearson curve and the Johnson curve are selected for capability index calculation and data modeling the normal-based index $C_{psk}$ is used as the model for non-normal process. A significant result of this research find that the ranking of the seven indices, $C_p,\;C_{pk},\;C_{pm},\;C^{\ast}_{pm},\;C_{pmk},\;C_s,\;C_{psk}$ in terms of sensitivity to departure of the process median from the target value T=M from the most sensitive one up to the least sensitive are $C_{psk},\;C_{s},\;C_{pmk},\;C^{\ast}_{pm},\;C_{pm},\;C_{pk},\;C_p$. i.e, By the criteria adopted for evaluation of PCI's $C_{psk}$ is the most sensitive to the departure of the process median from target and $C_p$ is least

  • PDF

A VANISHING THEOREM FOR REDUCIBLE SPACE CURVES AND THE CONSTRUCTION OF SMOOTH SPACE CURVES IN THE RANGE C

  • Ballico, Edoardo
    • Communications of the Korean Mathematical Society
    • /
    • v.34 no.1
    • /
    • pp.105-111
    • /
    • 2019
  • Let $Y{\subset}{\mathbb{P}}^3$ be a degree d reduced curve with only planar singularities. We prove that $h^i({\mathcal{I}}_Y(t))=0$, i = 1, 2, for all $t{\geq}d-2$. We use this result and linkage to construct some triples (d, g, s), $d>s^2$, with very large g for which there is a smooth and connected curve of degree d and genus g, $h^0({\mathcal{I}}_C(s))=1$ and describe the Hartshorne-Rao module of C.

THE SEQUENCE OF P-T CURVES AROUND A QUATERNARY INVARIANT POINT IN THE SYSTEM NaAlSiO4-KAlSiO4-SiO2-H2O (NaAlSiO4-KAlSiO4-SiO2-H2O 4성분계(成分系)의 불변점부근(不變點附近)의 P-T 곡선(曲線)의 변이(變移))

  • Kim, Ki-Tae
    • Economic and Environmental Geology
    • /
    • v.5 no.2
    • /
    • pp.77-86
    • /
    • 1972
  • The system NaAlSiO_4-KAlSiO_4-SiO_2-H_2O, Bowen's "Petrogeny's Residua System" of course is extremely important in understanding the phase relationships of igneous and metamorphic rock in the continental crust. The phase relationships in this system, however, have not been completely established in the P-T range above the Mohorovicic discontinuity. They need to be established. In this study, the most probable sequence of P-T curves around a quaternary invariant point(~5Kb/${\sim}635^{\circ}C$) in the system using Schreinemakers' rule, is deduced, essentially on the basis of Morse's(1969a and b) experimental data. Possible modifications of the sequence of the P-T curves considering likely changes of the invariant chemogram are also considered. It is concluded that the sequence of P-T curves around the invariant point (~5Kb/${\sim}635^{\circ}C$) is (L), (Anl), (Or), (V), (Ne) and (Ab) on the P-T projection, where the P-T curve (L) is extended towards lower P-T regions, and the (Anl) curve is extended towards a region of higher temperature and lower pressure from the invariant point respectively.

  • PDF

The comparison of the fatigue crack initiation life in a notch (노치부의 피로균열발생 수명 비교)

  • Kim, S.H.;Bae, S.I.;Ham, K.C.;Song, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.217-222
    • /
    • 2001
  • For the life evaluating of notched members, it is the best way that performing the real fatigue test of structure containing notch. But this method required generally much times and costs to evaluate fatigue life. So, generally we use the modified S-N curve or several methods to predict fatigue life. In this study, crack initiation life was evaluated by fatigue testing the SAE keyhole specimen and smooth specimen made of Al 7075-T6 alloys using the constant load then obtained S-N curve of smooth specimen and P-N curve of SAE keyhole specimen. And, fatigue lives of keyhole specimen are predicted using some life prediction methods (Nominal range I method, Nominal range II method, FEM analysis) for investigating experimented results, and that were compared with experimental data. Predicted fatigue lives by FEM analysis were corresponded with experimental data between 1/3times and 3times on the whole, and predicted fatigue lives using modified S-N curve (Nominal range I method, Nominal range II method) were nonconservative compared with that of FEM analysis.

  • PDF

No Adverse Outcomes of Video-Assisted Thoracoscopic Surgery Resection of cT2 Non-Small Cell Lung Cancer during the Learning Curve Period

  • Bilgi, Zeynep;Batirel, Hasan Fevzi;Yildizeli, Bedrettin;Bostanci, Korkut;Lacin, Tunc;Yuksel, Mustafa
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.275-280
    • /
    • 2017
  • Background: Video-assisted thoracoscopic surgery (VATS) anatomic lung resections are gradually becoming the standard surgical approach in early-stage non-small cell lung cancer (NSCLC). The technique is being applied in cases of larger tumors depending on the experience of the surgical team. The objective of this study was to compare early surgical and survival outcomes in patients undergoing anatomic pulmonary resections using VATS and thoracotomy techniques for clinical T2 NSCLC during the adaptation period of the surgical team to the VATS approach. Methods: The data of all patients who underwent anatomic pulmonary resection for NSCLC using VATS and open techniques since April 2012 were recorded to create a prospective lung cancer database. Clinical T2 NSCLC patients who underwent VATS anatomic lung resection were identified and compared with cT2 patients who underwent open resection. Results: Between April 2012 and August 2014, 269 anatomical resections for NSCLC were performed (80 VATS and 189 thoracotomy). Thirty-four VATS patients who had clinical T2 disease were identified and stage-matched to thoracotomy patients. The average tumor diameter was comparable ($34.2{\pm}11.1{\times}29.8{\pm}10.1mm$ vs. $32.3{\pm}9.8{\times}32.5{\pm}12.2mm$, p=0.4). Major complications were higher in the thoracotomy group (n=0 vs. n=5, p=0.053). There was no 30-day mortality, and the 2-year survival rate was 91% for VATS and 82% for thoracotomy patients (p=0.4). Conclusion: VATS anatomic resections in clinical T2 NSCLC tumors are safe and have perioperative and pathologic outcomes similar to those of thoracotomy, while remaining within the learning curve.

Fatigue Life Evaluation for Flange-Shaft Assembly of Front Loading Washing Machine (드럼세탁기 축계의 피로수명 평가)

  • Kim D.J.;We W.T.;Seok C.S.;Lee G.H.;Min J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.429-430
    • /
    • 2006
  • To estimate the fatigue life of flange-shaft assembly, fatigue test for flange material and bending fatigue test for flange-shaft assembly were conducted. Also, finite element analysis for flange-shaft assembly was conducted. Then, we have changed the obtained P-N curve to S-N curve using the finite element analysis results which were stress values at the location of fracture. The S-N curve of flange material itself was almost consistent with that of flange-shaft assembly, so it seems that the fatigue life of flange-shaft assembly could be estimated by using S-N curve for flange material and the stress at the location of fracture calculated by finite element methods.

  • PDF

Capacity of a transmission tower under downburst wind loading

  • Mara, T.G.;Hong, H.P.;Lee, C.S.;Ho, T.C.E.
    • Wind and Structures
    • /
    • v.22 no.1
    • /
    • pp.65-87
    • /
    • 2016
  • The wind velocity profile over the height of a structure in high intensity wind (HIW) events, such as downbursts, differs from that associated with atmospheric boundary layer (ABL) winds. Current design codes for lattice transmission structures contain only limited advice on the treatment of HIW effects, and structural design is carried out using wind load profiles and response factors derived for ABL winds. The present study assesses the load-deformation curve (capacity curve) of a transmission tower under modeled downburst wind loading, and compares it with that obtained for an ABL wind loading profile. The analysis considers nonlinear inelastic response under simulated downburst wind fields. The capacity curve is represented using the relationship between the base shear and the maximum tip displacement. The results indicate that the capacity curve remains relatively consistent between different downburst scenarios and an ABL loading profile. The use of the capacity curve avoids the difficulty associated with defining a reference wind speed and corresponding wind profile that are adequate and applicable for downburst and ABL winds, thereby allowing a direct comparison of response under synoptic and downburst events. Uncertainty propagation analysis is carried out to evaluate the tower capacity by considering the uncertainty in material properties and geometric variables. The results indicated the coefficient of variation of the tower capacity is small compared to those associated with extreme wind speeds.