• Title/Summary/Keyword: P wave & QT interval

Search Result 5, Processing Time 0.021 seconds

P Wave Detection based on QRST Cancellation Zero-One Substitution

  • Cho, Ik-Sung
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2021
  • Cardiac arrhythmias are common heart diseases and generally cause sudden cardiac death. Electrocardiogram (ECG) is an effective tool that can reveal the electrical activity of the heart and diagnose cardiac arrhythmias. We propose detection of P waves based on QRST cancellation zero-one substitution. After preprocessing, the QRST segment is determined by detecting the Q wave start point and T wave end point separately. The Q wave start point is detected by digital analyses of the QRS complex width, and the T wave end point is detected by computation of an indicator related to the area covered by the T wave curve. Then, we determine whether the sampled value of the signal is in the interval of the QRST segment and substitute zero or one for the value to cancel the QRST segment. Finally, the maximum amplitude is selected as the peak of the P wave in each RR interval of the residual signal. The average detection rate for the QT database was 97.67%.

Feature Extraction of ECG Signal for Heart Diseases Diagnoses (심장질환진단을 위한 ECG파형의 특징추출)

  • Kim, Hyun-Dong;Min, Chul-Hong;Kim, Tae-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.325-327
    • /
    • 2004
  • ECG limb lead II signal widely used to diagnosis heart diseases and it is essential to detect ECG events (onsets, offsets and peaks of the QRS complex P wave and T wave) and extract them from ECG signal for heart diseases diagnoses. However, it is very difficult to develop standardized feature extraction formulas since ECG signals are varying on patients and disease types. In this paper, simple feature extraction method from normal and abnormal types of ECG signals is proposed. As a signal features, heart rate, PR interval, QRS interval, QT interval, interval between S wave and baseline, and T wave types are extracted. To show the validity of proposed method, Right Bundle Branch Block (RBBB), Left Bundle Branch Block (LBBB), Sinus Bradycardia, and Sinus Tachycardia data from MIT-BIH arrhythmia database are used for feature extraction and the extraction results showed higher extraction capability compare to conventional formula based extraction method.

  • PDF

Studies on the Electrocadiogram in Non-human Primates Reared in Korea (國內 飼育 원숭이의 心電圖에 관한 硏究)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.

Cardioprotective effect of Argyreia speciosa (Burm. f) Boj. extracts against Isoproterenol- induced myocardial infarction in rats

  • Thakker, Shalin;Biradar, S.M.;Habbu, P.V.;Mahadevan, K.M.;Thippeswamy, B.S.;Veerapur, V.P.
    • Advances in Traditional Medicine
    • /
    • v.10 no.4
    • /
    • pp.278-287
    • /
    • 2010
  • The present study was undertaken to evaluate the protective effect of ethanol (EtAS), ethyl acetate (EAAS) and aqueous (AQAS) extracts of Argyreia speciosa (AS) roots against Isoproterenol (ISO)-induced myocardial infarction in rats. The animals were exposed to isoproterenol (200 mg/kg. s.c) twice at an interval of 24 hrs. Cardioprotective effect was assessed by observing ECG parameters, serum marker enzymes and histopathology of the heart. Pretreatment of EAAS, and EtAS (200 mg/kg) resulted in a significant (P < 0.001) increase in P wave, QRS complex and R-R interval, whereas heart rate, QT interval and cardiac cycle were maintained near to normal values. EtAS and EAAS showed significant (P < 0.05; P < 0.001) reduction in all the tested diagnostic markers compared to ISO treated group. Histological studies on the structural changes of heart tissue supported the protective activity of AS. The result suggest that treatment of AS prior to ISO has a significant role in protecting the animals from ISO induced myocardial infarction.

Evaluation of Electrocardiographic Index in Healthy Raccoon Dogs (Nyctereutes procyonoides) (건강한 너구리(Nyctereutes procyonoides)들의 심전계 지표에 대한 평가)

  • Hong, Won-Woo;Kim, Jong-Taek;Yang, Dong-Keun;Nam, Hyo-Seung;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.456-458
    • /
    • 2013
  • The aim of this study is to evaluate the reference value for electrocardiogram in healthy captive raccoon dogs. Forty-one free-ranging adult raccoon dogs rescued from Wildlife rescue centre, Kangwon National University were enrolled in this study. The 6-lead electrocardiogram was obtained in all raccoon dogs without any chemical restraints. The mean heart rate was $146.10{\pm}43.31$ beats/min (95% confidence interval 132.84~159.36 beats/min). The mean respiration rate was $35.73{\pm}11.56$ breaths/min (95% confidence interval 32.19~39.27 breaths/min). The mean systolic blood pressure was $136{\pm}29.26$ mmHg (95% confidence interval 127.99~145.91 mmHg). Electrocardiographical features were also evaluated in all raccoon dogs. The mean duration and amplitude of P-wave were $38.2{\pm}4.0$ ms (range 28-40 ms) and $0.128{\pm}0.039$ mV (range 0.09~0.20). The mean duration and amplitude of QRS complexes were $48.5{\pm}7.2ms$ (range 36-60 ms) and $1.330{\pm}0.650$ mV (range 0.15~2.30). The range of the mean electrical (QRS) axis was $-91^{\circ}{\sim}+96^{\circ}$ ($10^{\circ}{\sim}60^{\circ}$; 95% of confidence interval). The mean corrected QT (QTc) interval was $273.7{\pm}32.7ms$ (range 212-333 ms), while the mean PR interval was $76.1{\pm}10.0ms$ (range 50-82 ms). To the authors' knowledge, this is the first study to provide references in electrocardiogram (ECG) in healthy captive raccoon dogs.