• 제목/요약/키워드: P loading

검색결과 1,471건 처리시간 0.034초

동진강 해역 표층 퇴적물 중 인의 화학적 형태별 함량 (Fractions of Phosphorus in the Surficial Sediment of Dongjin Sea Area)

  • 이현정;손재권;박봉주;조재영
    • 농촌계획
    • /
    • 제11권4호
    • /
    • pp.25-31
    • /
    • 2005
  • The present study was carried out to investigate the P fractions of surfical sediment of Dongjin sea area. Furthermore, potential released loading of adsorbed and non-apatite inorganic phosphorus were investigated in the sediment of Dongjin sea area. The contents of phosphorus fractions of the surficial sediment in Dongjin sea area were adsorbed-P 0.06%, nonapatite inorganic-P 13.02%, apatite-P 60.22%, and residual-P 26.70%. The most abundant fraction was apatite-P, residual-P, nonapatite inorganic-P, and adsorbed-P followed it. Potential released loading of adsorbed and non-apatite inorganic phosphorus surveyed 2.6 and 597ton respectively. These results show that sediment-managing and interception from external pollution are needed for water environmental maintenance of Dongjin sea area.

Dynamic combination resonance characteristics of doubly curved panels subjected to non-uniform tensile edge loading with damping

  • Udar, Ratnakar. S.;Datta, P.K.
    • Structural Engineering and Mechanics
    • /
    • 제25권4호
    • /
    • pp.481-500
    • /
    • 2007
  • The dynamic instability of doubly curved panels, subjected to non-uniform tensile in-plane harmonic edge loading $P(t)=P_s+P_d\;{\cos}{\Omega}t$ is investigated. The present work deals with the problem of the occurrence of combination resonances in contrast to simple resonances in parametrically excited doubly curved panels. Analytical expressions for the instability regions are obtained at ${\Omega}={\omega}_m+{\omega}_n$, (${\Omega}$ is the excitation frequency and ${\omega}_m$ and ${\omega}_n$ are the natural frequencies of the system) by using the method of multiple scales. It is shown that, besides the principal instability region at ${\Omega}=2{\omega}_1$, where ${\omega}_1$ is the fundamental frequency, other cases of ${\Omega}={\omega}_m+{\omega}_n$, related to other modes, can be of major importance and yield a significantly enlarged instability region. The effects of edge loading, curvature, damping and the static load factor on dynamic instability behavior of simply supported doubly curved panels are studied. The results show that under localized edge loading, combination resonance zones are as important as simple resonance zones. The effects of damping show that there is a finite critical value of the dynamic load factor for each instability region below which the curved panels cannot become dynamically unstable. This example of simultaneous excitation of two modes, each oscillating steadily at its own natural frequency, may be of considerable interest in vibration testing of actual structures.

Hydroxyapatite-coated implant: Clinical prognosis assessment via a retrospective follow-up study for the average of 3 years

  • Jung, Jun-Hong;Kim, Sang-Yun;Yi, Yang-Jin;Lee, Bu-Kyu;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.85-92
    • /
    • 2018
  • PURPOSE. This research evaluated clinical outcomes of two types of hydroxyapatite (HA)-coated implants: OT (Osstem TS III-HA, Osstem implant Co., Busan, Korea) and ZM (Zimmer TSV-HA, Zimmer dental, Carlsbad, USA). MATERIALS AND METHODS. The research was conducted on 303 implants (89 of OT, 214 of ZM), which were placed from January 16, 2010 to December 20, 2012. The prognosis was evaluated in terms of success rates, survival rates, annual marginal bone loss, and implant stability quotients (ISQ). The samples were classified into immediate, early, conventional, and delayed groups according to the loading time. RESULTS. Overall, there were no significant differences between OT and ZM in success rates, survival rates, and annual marginal bone loss, except for the result of secondary stability. OT showed $77.83{\pm}8.23ISQ$, which was marginally higher than $76.09{\pm}6.90ISQ$ of ZM (P<.05). In terms of healing periods, only immediate loading showed statistically significant differences (P<.05). Differences between OT and ZM were observed in terms of two indices, the annual marginal bone loss ($0.17{\pm}0.58mm/year$ < $0.45{\pm}0.80mm/year$) and secondary stability ($84.36{\pm}3.80ISQ$ > $82.48{\pm}3.69ISQ$) (P<.05). OT and ZM did not have any statistically significant differences in early, conventional, and delayed loading (P>.05). CONCLUSION. OT (97.75%) and ZM (98.50%) showed relatively good outcomes in terms of survival rates. In general, OT and ZM did not show statistically significant differences in most indices (P>.05), although OT performed marginally better than ZM in the immediate loading and 1-stage surgery (P<.05).

다변량분석법을 이용한 금강 유역의 수질오염특성 연구 (Evaluation of the Geum River by Multivariate Analysis: Principal Component Analysis and Factor Analysis)

  • 김미아;이재관;조경덕
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.161-168
    • /
    • 2007
  • The main aim of this work is focus on the Geum river water quality evaluation of pollution data obtained by monitoring measurement during the period 2001-2005. The complex data matrix 19 (entire monitoring stations)*13 (parameters), 60 (month)*13 (parameters) and 20 (season)*13 (parameters) were treated with different multivariate techniques such as factor analysis/principal component analysis (FA/PCA). FA/PCA identified two factor (19*13) classified pollutant Loading factor (BOD, COD, pH, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P, Chl-a), seasonal factor (water temp, SS) and three Factor (60*13, 20*13) classified pollutant Loading factor (BOD, COD, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P), seasonal factor (water temp, SS) and metabolic factor (Chl-a, pH). Loadings of pollutant factor is potent influence main factor in the Geum river which is explained by loadings of pollutant factor at whole sampling stations (71.16%), month (52.75%) and season (56.57%) of main water quality stations. Result of this study is that pollutant loading factor is affected at Gongju 1, 2, Buyeo 1, 2, Gangkyeong, Yeongi stations by entire stations and entire month (Gongju 1, Cheongwon stations), April, May, July and August (buyeo 1) by month. Also the pollutant Loading factor is season gives an influence in winter (Gongju 1, buyeo 1) from main sampling stations, but Cheongwon characteristic is non-seasonal influenced. This study presents necessity and usefulness of multivariate statistic techniques for evaluation and interpretation of large complex data set with a view to get better information data effective management of water sources.

농촌유역의 강우사상별 농업 비점원오염물질 유출특성 (Characteristics of Agricultural Non-point Source Pollutants by Rainfall Events in Rural Watersheds)

  • 김진호;한국헌;이종식
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.69-77
    • /
    • 2008
  • This study was conducted to know the characteristics of agricultural non-point source pollutants runoff by rainfall events at the upper catchment of Goseong reservoir in Gonjy city, Chungnam Province. For this study, the monitoring sites of the research catchment were set nineteen during the research period (between June 2005 and October 2006). Average runoff coefficient were observed 0.51 in 2005, 0.71 in 2006, respectively. The correlation coefficient (r) between the rainfall and peak-flow was investigated 0.787. By rainfall events, the water quality of the sites were shown like this : BOD 0.555~9.60 mg/L, T-N 0.01~13.50 mg/L, T-P 0.002~2.952 mg/L, and SS N.D~820.0 mg/L. The strong rainfall intensity was the most important factor of the soil erosion. The gabs of the arithmetic mean concentrations and the flow weighted mean concentrations were observed as the followings : BOD 0.0~29.2%, T-N 0.1~11.4%, T-P 0.4~95.2%, and SS 1.7~57.0% in 2005, and BOD 1.0~11.9%, T-N 0.7~7.3%, T-P 9.9~36.5%, and SS 6.6~36.5% in 2006, respectively. The BOD pollution load was 2,117 kg (36% of the total BOD loading of survey periods) while, T-N was 3,209.0 kg (27.9% of the total T-N loading of survey periods), T-P was 136.4 kg (37.4% of the total T-P loading of survey periods) and SS was 72,733.8 kg (51.8% of the total SS loading of survey periods) in the year 2005. In case of 2006, BOD load was 1,321.7, T-N was 2,845.8, T-P was 42.9, and SS was 16,275.8 kg, respectively.

만성요통 환자의 테이핑 적용 시체간의 굴곡과 선전의 근력과 지구력의 변화 측정 (The Effect of Kinesio Taping on the Change of Muscle Strength and Endurance in Trunk Flexion and Extension in Chronic Low Back Pain(CLBP))

  • 김수형
    • 대한정형도수물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.40-48
    • /
    • 2005
  • In this study, the muscle strength and endurance of the lumbar at flexion and extension were determined using an isokinetic muscle strength meter (Biodex) in patients with chronic lumbar go (10 male and 10 females), and the changes in muscle strength and endurance of the lumbar at flexion and extension after application of Y-shaped sacrospinalis muscle taping, typically used for patient with lumbar go, were studied. In addition, the sacrospinalis muscle taping of a different shape (I-shaped taping) was applied bilaterally centering on the spine, and the muscle strength and endurance of the lumbar at flexion and extension were determined and compared with those before taping. In addition, the results after application of Y-shaped taping and I-shaped taping were also compared. 1. The extensor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio Taping and after application of Y-shaped taping showed the level of significance (p<.05). The flexor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio taping and after application of Y-shaped taping did not show the level of significance. 2. The flexor muscle endurance of the lumbar at loading of $90^{\circ}$/sec before application of kinesio Taping and application of Y-shaped taping did not show the level of significance. The extensor muscle endurance of the lumbar at loading of $90^{\circ}$/sec before application of kinesio Taping and after application of Y-shaped taping did not show the level of significance. 3. The extensor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio Taping and after application of I-shaped taping showed the level of significance (p<.05). The flexor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio Taping and after application of I-shaped taping showed the level of significance (p<.05). 4. The flexor muscle endurance of the lumbar at loading of $90^{\circ}$/sec before application of kinesio taping and after application of I-shaped taping showed the level of significance. The extensor muscle strength of the lumbar at loading of $90^{\circ}$/sec before application of kinesio Taping and after application of I-shaped taping showed the level of significance (p<.05). 5. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the flexor muscle strength of the lumbar at loading of $60^{\circ}$/sec did not show the level of significance. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the extensor muscle strength of the lumbar at loading of $60^{\circ}$/ sec showed the level of significance (p<.05). 6. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the flexor muscle strength of the lumbar at loading of $90^{\circ}$/sec did not show the level of significance. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the extensor muscle strength of the lumbar at loading of $90^{\circ}$/sec did not showed the level of significance (p<.05).

  • PDF

Altered Regulation of Renal Acid Base Transporters in Response to Ammonium Chloride Loading in Rats

  • Kim, Eun-Young;Choi, Joon-Seok;Lee, Ko-Eun;Kim, Chang-Seong;Bae, Eun-Hui;Ma, Seong-Kwon;Kim, Suhn-Hee;Lee, Jong-Un;Kim, Soo-Wan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제16권2호
    • /
    • pp.91-95
    • /
    • 2012
  • The role of the kidney in combating metabolic acidosis has been a subject of considerable interest for many years. The present study was aimed to determine whether there is an altered regulation of renal acid base transporters in acute and chronic acid loading. Male Sprague-Dawley rats were used. Metabolic acidosis was induced by administration of $NH_4Cl$ for 2 days (acute) and for 7days (chronic). The serum and urinary pH and bicarbonate were measured. The protein expression of renal acid base transporters [type 3 $Na^+/H^+$ exchanger (NHE3), type 1 $Na^+/{HCO_3}^-$ cotransporter (NBC1), Na-$K^+$ ATPase, $H^+$-ATPase, anion exchanger-1 (AE-1)] was measured by semiquantitative immunoblotting. Serum bicarbonate and pH were decreased in acute acid loading rats compared with controls. Accordingly, urinary pH decreased. The protein expression of NHE3, $H^+$-ATPase, AE-1 and NBC1 was not changed. In chronic acid loading rats, serum bicarbonate and pH were not changed, while urinary pH was decreased compared with controls. The protein expression of NHE3, $H^+$-ATPase was increased in the renal cortex of chronic acid loading rats. These results suggest that unaltered expression of acid transporters combined with acute acid loading may contribute to the development of acidosis. The subsequent increased expression of NHE3, $H^+$-ATPase in the kidney may play a role in promoting acid excretion in the later stage of acid loading, which counteract the development of metabolic acidosis.

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants

  • Mohammed, Hnd Hadi;Lee, Jin-Han;Bae, Ji-Myung;Cho, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.62-69
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION. Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

유기물부하량 증가에 따른 음폐수 혐기성소화의 특성 분석 (Characteristics of Anaerobic Digestion using Food waste leachate under Increased Organic Loading rate)

  • 정재훈;정우진;장순웅;김진태;정성엽;양승연
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1127-1134
    • /
    • 2022
  • Herein , the effect of changes in the organic loading rate in anaerobic digestion was evaluated. The experiment was carried out by a laboratory -scale semi-continuous stirred tank reactor, and feedstock was food-waste leached. The organic loading rate was increased by 0.5 kgVS/m3 in each phase from 1.0 kgVS/m3 to 4.0 kgVS/m3. At the end of the operation, to check the failure of the reactor, the organic loading rate was increased by 1.0 kgVS/m3 in each phase and reached 6.0 kgVS/m3. This shows that the biogas yield decreased as organic loading rate increased. Biogas production seemed to be unstable at 3.5-6.0 kgVS/m3. Moreover, biogas production dramatically fell to approximately 0 mL at 6.0 kgVS/m3, which was decided as the operation failure on the 16th day of the las tphase. The result of the reactor analysis shows that the cumulation of volatile fatty acid increased as the organic loading rate increased. This seems to occur due to the decreasein pH in the reactor and led to extinction of anaerobic bacteria, which were the biogas products. Although the buffer compound (alkalinity) could prevent the decline in pH, the concentration of alkalinity was found to be lacking at a high organic loading rate

Nondestructive detection of crack density in ultra-high performance concrete using multiple ultrasound measurements: Evidence of microstructural change

  • Seungo Baek;Bada Lee;Jeong Hoon Rhee;Yejin Kim;Hyoeun Kim;Seung Kwan Hong;Goangseup Zi;Gun Kim;Tae Sup Yun
    • Computers and Concrete
    • /
    • 제33권4호
    • /
    • pp.399-407
    • /
    • 2024
  • This study nondestructively examined the evolution of crack density in ultra-high performance concrete (UHPC) upon cyclic loading. Uniaxial compression was repeatedly applied to the cylindrical specimens at levels corresponding to 32% and 53% of the maximum load-bearing capacity, each at a steady strain rate. At each stage, both P-wave and S-wave velocities were measured in the absence of the applied load. In particular, the continuous monitoring of P-wave velocity from the first loading prior to the second loading allowed real-time observation of the strengthening effect during loading and the recovery effect afterwards. Increasing the number of cycles resulted in the reduction of both elastic wave velocities and Young's modulus, along with a slight rise in Poisson's ratio in both tested cases. The computed crack density showed a monotonically increasing trend with repeated loading, more significant at 53% than at 32% loading. Furthermore, the spatial distribution of the crack density along the height was achieved, validating the directional dependency of microcracking development. This study demonstrated the capability of the crack density to capture the evolution of microcracks in UHPC under cyclic loading condition, as an early-stage damage indicator.