• Title/Summary/Keyword: Ozonized water

Search Result 19, Processing Time 0.018 seconds

A Study about Ozonized Water Making that Use $O_3$ (오존화 기체를 이용한 오존수 제조에 관한 연구)

  • Park, Hyun-Mi;Lee, Chang-Ho;Lee, Sang-Geun;Song, Hyun-Jig;Yoon, Byeng-Han;Lim, Chang-Ho;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.339-342
    • /
    • 2004
  • It is research about special quality of ozone gas concentration and dissolved ozone concentration that show according to change of flow rate when liquefied ozone gas in water. If increase flow rate of ozone gas, ozone concentration increases being proportional and amount to fixed flow rate, dissolved ozone concentration was measured low. When ozone concentration How rate 1000 [ppm], dissolved ozone concentration smelted to flow rate 1.5[Q] for 28 [min] is $0.1740{\sim}0.8020[mg/l]$. Could know that half-life is most short by 3 minutes 8 seconds in flow rate 1.5 [Q]. And ozone smelted 20 minutes later after half-life measurement became disjointing all.

  • PDF

A Study on Ozonized Water Spraying System (오존무 분사장치 개발에 관한 연구)

  • Cho, Kook-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.267-270
    • /
    • 2007
  • 오존무 분사장치는 흡입구와 내에 소정의 공간이 형성된 케이스와 자동 손잡이와 $360^{\circ}$회전이 가능해 운반 및 이동이 간편한 케이스, 상기 케이스의 내부 소정 부위에 공기 흡입구로 흡입되는 공기 중에 포함된 먼지 및 습기를 제거하는 제습 장치와, 원료가스인 공기를 일정하게 제공하는 송풍기, 강력한 살균 소독기능을 지닌 오존발생기, 오존을 발생시키기 위한 고주파 펄스 전원장치, 입자경이 $3{\sim}40{\mu}m$이하의 이류체 미세 분사형 노즐, 살수통(물을 담는 용기) 및 기능 조절부(펄스전원제어, 타이머 조절, 송풍기 제어, 이류체 미세 분사형 노즐스위치 제어)로 성되어 작동하는 것으로 일반적인 가습기와는 다르다. 그리고 강력한 살균, 소독, 탈취 및 대기의 정화 기능이 있는 오존을 이용하는 동시에 기존의 방식보다 간단한 구조의 분무발생 수단을 구비함으로써 전체적으로 구성을 간단하게 하면서 대기 정화 효율을 향상시키는 장점이 있다.

  • PDF

Sterilization Effects of $\gamma-ray$ and Ozone on Microoganisms Contaminated in Angelica keiskei Powde (신선초 분말에 오염시킨 미생물에 대한 감마선과 오존의 살균효과)

  • 권오진;박순연;김광훈;이현자;변명우
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.3
    • /
    • pp.221-225
    • /
    • 1996
  • For the purpose of improving hygienic quality of health-foods, sterilization effects of ${\gamma}$-ray and ozone on microoganisms associated with food cultured in the media and contaminated in Angelica keiskei powder were investigated. Ozone was immersed in water and sprayed in air, on the concentration of 3 mg liter-1 at an air flow rate of 5 liter min-3. Test strains cultured in the media completely inhibited by ${\gamma}$-ray at irradiation doses of 0.25~2 kGy. In the case of ozone, test bacteria inactivated after treatment of 10~20 minutes, but test mold, Aspergillus flavus was not effective. Strains contaminated in Angelica keiskei powder completely inhibited by ${\gamma}$-ray at irradiation doses of 2.5~7.5 kGy. However, when the powder was sprayed with ozonized air for 10hours, Bacillus subtilis and Staphylococcus aureus among five strains were eliminated.

  • PDF

A study on the Production of Ozonized Water for Environment Improvement by Gaseous Discharge (기체방전을 이용한 환경개선용 오존수 제조에 관한 연구)

  • Lee, C.H.;Soong, H.J.;Yoon, B.H.;Kim, J.H.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.192-193
    • /
    • 2006
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating (1) discharge characteristics with variation of output voltage power supply, flow rate and gap distance (2) ozone generation and solubility characteristics with variation of flow rate, gap distance and discharge power. Pure oxygen was used as process gas of the co-axial type ozonizer.

  • PDF

A new cleaning concept for display process with electrolyzed anode water (전해 양극수를 이용한 디스플레이 신 세정 공정)

  • Choi Minki;Cha Jiyung;Kim Younggeun;Ryoo Kunkul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.99-102
    • /
    • 2004
  • Display process has adopted RCA clean, being applied to large area and coped with environmental issue for last ten years. However, the approaching concept of ozonized, hydrogenised, or electrolyzed water cleaning technologies is within RCA clean paradigm. In this work, only electrolyzed anode water was applied to clean particles and organics as well as metals based on Pourbaix concept, and as a test vehicle, MgO particles were introduced to prove the new concept. The electrolyzed anode water is very oxidative with high oxidation reduction potential(ORP) and low in pH of more than 900mV and 3.1, respectively. MgO particles were immerged in the anode water and its weight losses due to dissolution were measured with time. Weight losses were in the ranges of 100 to 500 micrograms in 250m1 anode waters depending on their ORP and pH. Therefore it was concluded that the cleaning radicals in the anode water was at least in the range of 1 to 5E20 ea per 250 ml anode water equivalent to IE18 ea/cm3. Hence it can be assumed that the anode water be applied to display cleaning since 1E10 to IE15 ea/cm3 ranges of contaminants are being treated. In addition, it was observed that anode water does not develop micro-roughness on hydrophobic surface while it does on the native silicon oxide.

  • PDF

Change of Microbial Community on Ozonation of Sewage Sludge to Reduce Excess Sludge Production (폐슬러지 감량화 및 재활용을 위한 오존 처리시 하수슬러지내의 미생물 군집구조의 변화)

  • Hong, Jun-Seok;Lim, Byung-Ran;Ahn, Kyu-Hong;Maeng, Sung-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2004
  • The change of the microbial community structure in excess sludge of different sewage treatment plants by ozone treatment was investigated by quinone profiles. The resulting ozone dosage ranged from 0.1 to $0.4gO_3/gTS$. In terms of overall sludge reduction, more than 50% reduction of the total sludge mass could be achieved by ozone treatment at $0.4gO_3/gTS$. Quinone concentration and type in sludge of different treatment plants were remarkably decreases with increasing ozone dose. Ubiquinones(UQs)-8, -10 and MK-8 were still remained in the ozonized sludge at $0.4gO_3/gTS$. The results of this study showed that the remaining microorganisms belong to UQs-8, -10 and MK-8 were difficult to destruct cell membrane or wall by ozonation. Fecal Streptococci and Salmonella were not detected at ozone dose of $0.2gO_3/gTS$, but Fecal Coliform was not detected at ozone dose of $0.4gO_3/gTS$.

A New Cleaning Concept for Display Manufacturing Process with Electrolyzed Anode Water (전해 양극수를 이용한 새로운 디스플레이 세정)

  • Ryoo Kunkul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.1
    • /
    • pp.78-82
    • /
    • 2005
  • Display manufacturing process has adopted RCA cleaning, applying to larger area and coping with environmental issue for last ten years. However, the approaching concept of ozonized, hydrogenised, or electrolyzed water cleaning technologies is within RCA clean paradigm. In this work, only electrolyzed anode water was applied to clean particles and organics as well as metals based on Pourbaix concept, and as a test vehicle, MgO particles were introduced to prove the new concept. The electrolyzed anode water is very oxidative with high oxidation reduction potential (ORP) and low in pH of more than 900 mV and 3.1, respectively. MgO particles were immersed in the anode water and its weight losses due to dissolution were measured with time. Weight losses were in the ranges of 100 to 500 micrograms in 250 ml anode water depending on their ORP and pH. Therefore it was concluded that the cleaning radicals in the anode water was at least in the range of 1 to $5{\times}10^{20}$ ea per 250 ml anode water equivalent to $1{\times}10^{18} ea/cm^2$. Hence it can be assumed that the anode water applied to display cleaning from now on $1{\times}10^{10}$ to $1{\times}10^{15} ea/cm^2$ ranges of contaminants are being treated. In addition, it was observed that anode water did not develop micro-roughness on hydrophobic surface while it did on the native silicon oxide.

  • PDF

A Study on the Ozonation of Aquatic Humic Substances(AHS) Extracted from Soyang Lake Water (소양호에서 추출한 수중 부식질(AHS)의 오존처리에 대한 연구)

  • An, Bok-Yeop;Rhee, Dong-Seok;Shin, Hyun-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.453-461
    • /
    • 2000
  • Aquatic humic substance (AHS) was extracted from Soyang lake water using XAD-8 resin. and its concentration distribution in the lake from May to October. 1997 was determined. Ozonation characteristics of the AHS were studied as factors of pH, carbonate ion concentration. and the biodegradability and structural changes of the AHS were also investigated after ozonaticn. DOC distribution in Soyang Lake water was 1~3 mg/L. and the concentrations of AHS ranged between 0.2~0.8 mg/L. which was corresponding to 20~30% of DOC. AHS was composed of around 20% of HA and 80% of FA. The optimum pH value for AHS ozonation was in range of pH 7~9. When carbonate ions were added for AHS ozonation as a ladical scavenger. it was found that DOC removals were decreased. and the absorbance decreases were increased slightly. Biodegradability of the ozonized AHS was 50% higher than that of unozonated AHS. $^{13}C-NMR$ analysis showed that the aromatic compounds of AHS, after ozonation, were decreased from 49% to 17%. and the aliphatic and carboxylic compounds were increased from 34% to 51% and from 17% to 32%. respectively.

  • PDF

The Study on Ozone Treatment of Wasting Activated Sludge for VFA Production and Reuse as Carbon Source for Phosphorus Release (잉여슬러지의 오존분해에 따른 VFA의 생성 및 인 방출을 위한 탄소원으로의 재이용 가능성에 관한 연구)

  • Ko, Eun-Taek;Cho, Jin-Woo;Park, Eun-Young;Ahn, Kyu-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1052-1057
    • /
    • 2005
  • Recently, the ozone treatment of wasting activated sludge has become one of the effective and feasible process for the sludge reduction. The objective of this study is to investigate the availability of ozonized wasting sludge on external carbon sources 13r phosphorus release. Experiment results showed that the ozone treatment of activated sludge could produce a large amount of VFA such as acetic acid and isobutyric acid. For example, 50.24 mg/L acetic acid was produced with the ozone dose of 0.05 g $O_3/g$ SS, and 123.56 mg/L acetic acid with 0.5 g $O_3/g$ SS. The higher ozone dose was applied, the more VFA was produced from sludge reduction into a limited point. Finally, using ozonated sludge as only carbon source, the batch experiment, to measure phosphorus release rate in anaerobic condition were performed. The specific phosphorus release rates were investigated as 0.94, 1.37, 1.48, 1.68 mg P/g VSS/hr with ozone dose of 0.05, 0.1, 0.2, 0.5 g $O_3/g$ SS, respectively. Considering the degree of mineralization, VFA production, phosphorus release rate, and economical aspect, the optimal ozone dose for sludge reduction and using carbon sources ranged from 0.05 to 0.1 g $O_3/g$ SS.