Evaluation of Ozone Application for Drinking Water Treatment Process Using DAF (DAF를 이용한 정수처리 공정에서의 오존 적용성 평가)

  • Kang, Tae-Hee;Oh, Byung-Soo;Cheong, Youn-Cheong;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.567-572
    • /
    • 2005
  • In this study, a lab-scale test was performed to apply the ozone process in drinking water treatment plant using dissolved ai, flotation(DAF). The kinetic study on the ozone decay and hydroxyl(OH) radical formation was investigated by several parameters, such as I.D(Instantaneous ozone demand), $k_c$(ozone decomposition rate), ozone-Ct and OH radical-Ct. Ozonation of several target waters, such as raw water, DAF treated water and filtrate, was conducted to select the optimum position and dosage of ozone process. The highest value of Ozone-Ct and OH radical-Ct was observed at DAF treated water at initial run time($0{\sim}30\;min$). From the results of ozonation, the intermediate ozonation was proposed as the optimum position and the effective dose of ozone was determined to be $1{\sim}2\;mg/L$.

FORMATION OF KETOACIDS AND AOC DURING OZONATION IN DRINKING WATER

  • Lee, Kyung-Hyuk
    • Environmental Engineering Research
    • /
    • v.11 no.6
    • /
    • pp.293-302
    • /
    • 2006
  • The reaction of ozone with NOM (Natural Organic Matter) can occur by two different pathways: that involving molecular ozone and by way of reactions with hydroxyl radicals which are produced from the decomposition of molecular ozone. As such, the formation of ketoacids and Assimilable Organic Carbon (AOC) can be controlled by controlling the pathway by which ozone reacts with NOM. The ratios of $[OH{\cdot}]/[O_3]$ ($R_{CT}$ values) were determined under the various ozonation conditions. The $R_{CT}$ values increased with increasing initial ozone concentration. The $R_{CT}$ values (ranges from 10 to $35^{\circ}C$) increased linearly as temperature increased (within the range from 10 to $35^{\circ}C$). However, $R_{CT}$ was independent of hydraulic retention time (HRT). Operational conditions were found to affect the formation of AOC. The conditions where the molecular ozone reaction predominated resulted in an increase in the formation of AOC.

Evaluation of Disinfection Characteristics of Ozone, UV Processes for Bacillus Subtilis Spores Inactivation (Bacillus Subtilis Spores 불활성화 실험을 통한 오존, UV 공정의 소독 특성 평가)

  • Jung, Yeon Jung;Oh, Byung Soo;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.672-677
    • /
    • 2006
  • Ozone/UV combined process is an effective technique to enhance generation of OH radical which is non-selective and powerful oxidant. The objective of this study is to evaluate the inactivation rates of B. subtilis spores by three candidate processes (ozone alone, UV alone, ozone/UV combined processes) at 4 and $20^{\circ}$ and to investigate the effects of OH radical on inactivation of B. subtilis spores. On the UV alone process, required UV dosages for lag phase and 3-log inactivation of B. subtilis spores were determined as $8.9mJ/cm^2$ and $47mJ/cm^2$. However, the inactivation of B. subtilis spores didn't occured beyond 4.5-log inactivation despite increasing UV dose. The inactivation of B. subtilis spores by ozone alone and ozone/UV combined process was investigated with ozone CT (Concentration of disinfectant ${\times}$ Contact time) concept. As a result, inactivation of B. subtilis spores by ozone/UV combined process was faster than by ozone alone, and especially $CT_{lag}$ value B. subtilis spores in the presence and absence of t-BuOH, OH radical scavenger, was investigated to evaluate effects of OH radical formed during ozone/UV combined process. We found that OH radical plays important roles on inactivation of B. subtilis spores.

Study on performance improved design of pressure-type ozone contactor in multistorey water treatment plant by CFD (CFD에 의한 수직형 정수처리 실증시설 내 압력식 오존접촉조 성능개선에 관한 연구)

  • Choi, Jong-Woong;Kim, Seong-Su;Kim, Jeong-Hyun;Kim, Kwanyeop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.431-440
    • /
    • 2014
  • The ozonation process has been widely used for drinking water disinfection around the world. Recently, the pressurized ozone contactor, in which the side stream typed ozone injection method is installed, has been applied to water treatment system. In this study, numerical calculations were conducted to compare prototype and screw-type ozone contactors based on hydraulic effectiveness in more details. The prototype ozone contactor was already installed and operated in domestic water treatment plant, and the screw-type is the suggested one for improving ozone contact efficiency installing the screw plate to the prototype. Screw turn numbers of screw plate were changed as 3, 5, 7 and 9, respectively for numerical simulation. The CT(concentration of disinfectant in mg/L times time in minutes) value was considered as one of the options for evaluating disinfection ability. From the results, it could be concluded that the performance of the screw-type is higher than that of the protype contactor by controlling the variable T as the tracer time. Also, Morill index of the screw-type(turn numbers = 5 ) appeared to be lower than the other.

Inactivation Effect of Cryptosporidium by Ozone and UV (Ozone과 UV를 이용한 Cryptosporidium의 불활성화 효과)

  • Kim, Yun-Hee;Lee, Chul-Hee;Lee, Shun-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • The objective of this study was to investigate the inactivation characteristics of Cryptosporidium oocysts by ozone and UV and to suggest the better, disinfection method. The inactivation CT value of 1 log(90%) and 2 log(99%) in of one disinfection, which is an index of disinfection for inactivation effect by ozone, were respectively 5.77 $mg{\cdot}min/L$ and 21.30 $mg{\cdot}min/L$. The inactivation in UV disinfection was not affected by pHs(5, 7 and 9), low turbidity(5 and below NTU) and UV intensity(0.2 and 0.6 $mWs/cm^2$) but obviously decreased at high turbidity over 20 NTU. Therefore UV disinfection capacity can be obtained when a good turbidity removal in drinking water treatment process is achieved. And if oocysts is exposed by high UV over 0.6 mWs/cm2 during enough time, the better inactivation effect will be obtained.

A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application (오존의 정수처리 적용을 위한 오존소비인자에 관한 연구)

  • Kang, Tae-Hee;Oh, Byung-Soo;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.663-669
    • /
    • 2005
  • The aim of this study was to investigate the ozone decay pattern for the effective application of ozone in drinking water treatment. In order to measure the ozone decomposition in water, ozone measuring instrument was developed with flow injection analysis (FIA) method. From the result of continuous residual ozone concentration in water, it was confirmed that the ozone decay pattern was divided with instantaneous ozone demand(I.D) and pseudo first-order rate($k_c$) phases, which were influenced by the variation of ozone dose. The empirical model obtained from I.D and $k_c$ values enabled us to predict the residual ozone concentration according to the reaction time, showing the high correlation between model and experimental values. The concentration of OH radical and $R__{ct}$ could be indirectly measured by OH radical probe compound. In both I.D and $k_c$ phases, the production pattern of OH radical could be observed, which was also affected by the variation of ozone dose. Finally, it was confirmed that the ozone consumption rate was varied according to the each drinking water treatment process and seasoning. Therefore, the optimum position and dosage of ozone have to be selected by considering various factors.

Characteristic behaviors of ozone decomposition and oxidation of pharmaceuticals during ozonation of surface waters in Ulsan (울산시 상수원수에서의 오존분해 특성 및 의약물질 분해 거동 연구)

  • Lee, Hye-Jin;Lee, Hongshin;Lee, Changha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2013
  • This study demonstrates the oxidative degradation of pharmaceutical compounds during ozonation of surface waters in Ulsan. Diclofenac, carbamazepine, bezafibrate, and ibuprofen were selected as surrogate pharmaceutical compounds, and ozonation experiments were performed using raw waters collected from the Sayeon Dam and the Hoeya Dam in Ulsan. Diclofenac and carbamazepine which have high reactivity with molecular ozone showed higher removal efficiencies than bezafibrate and ibuprofen during ozonation. The addition of tert-butanol, a hydroxyl radical scavenger, increased the removal efficiencies of diclofenac and carbamazepine by increasing the ozone exposure. However, the oxidation of bezafibrate and ibuprofen was inhibited by the presence of tert-butanol due to the suppression of the exposure to hydroxyl radical. The elimination of the selected pharmaceuticals could be successfully predicted by the kinetic model base on the $R_{ct}$ concept. Depending on the experimental condition, $R_{ct}$ values were determined to be $(1.54{\sim}3.32){\times}10^{-7}$ and $(1.19{\sim}3.04){\times}10^{-7}$ for the Sayeon Dam and the Hoeya Dam waters, respectively. Relatively high $R_{ct}$ values indicate that the conversion of $O_3$ into $^{\cdot}OH$ is more pronounced for surface waters in Ulsan compared to other water sources.

Comparison of Chlorine, Chlorine Dioxide and Ozone as Disinfectants in Drinking Water (정수소독공정에 이용되는 염소, 이산화염소, 오존 소독제의 비교, 고찰에 관한 연구)

  • Lee, Yoon-Jin;Lee, Sun-Jong;Lee, Dong-Chan;Kim, Hyun;Lee, Hwan;Lee, Cheol-Hyo;Nam, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.1-8
    • /
    • 2002
  • The experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform as a general indicator organism based on chlorine, chlorine dioxide and ozone as disinfectants. The water sam-ples were taken from the outlet of settling basin in a conventional surface water treatment system that is provided with the raw water drawn from the mid-stream of the Han River. The inactivation of total coliform was experimentally ana-lyzed for the dose of disinfectant contact time, pH, Temperature and DOC. The nearly 2.4,3.0,3.9 log inactivation of total coliform killed by injecting 1 mか1 at 5 minutes for chlorine, chlorine dioxide and ozone. For the inactivation of 99.9%(3 log), Disinfectants required were 1.70, 1.00 and 0.60 mか1 for chlorine, chlorine dioxide and ozone, respec-tively. The higher the pH is, the poorer the disinfections effects are in the range of pH 6-9 by using chlorine and ozone. But the irfluence of pH value on killing effects of chlorine dioxide is weak. The parameters estimated by the models of Chick-Watson, Hom, and Selleck from our experimental data obtained for chlorine are: log(N/ $N_{0}$ )=-0.16 CT with n= 1, log(N/ $N_{0}$ )=-0.71 $C^{0.87}$T with n$\neq$1, for Chicks-Watson model, log (N/ $N_{0}$ )= -1.87 $C^{0.47}$ $T^{0.36}$ for Hom model. For chlorine dioxide are: log(N/ $N_{0}$ )= -1.53 CT with n = 1, log(N/ $N_{0}$ )= -2.29 $C^{0.94}$T with n$\neq$1,, for Chicks-Watson model, log(N/ $N_{0}$ )= -3.64 $C^{0.43}$ $T^{0.24}$ for Hom model and for ozone are: log(N/ $N_{0}$ )= -2.59 CT with n = 1, log(N/ $N_{0}$ )= -2.28 $C^{0.36}$T with n$\neq$1, for Chicks-Watson model, log(N/ $N_{0}$ )= -4.53 $C^{0.26}$ $T^{0.19}$ for Hom model.19/ for Hom model.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

Inactivation of Infectious Cryptosporidium parvum by Various Disinfectants (다양한 소독제에 의한 감염성 크립토스포리디움 불활성화율 평가)

  • Byun, Seung-Heon;Lee, Mok-Young;Cho, Eun-Ju;Yoon, Tae-Ho;Kim, Tae-Ho;Han, Sun-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.533-539
    • /
    • 2007
  • Cell culture infectivity assay using HCT-8 cell was combined with most-probable-number technique to evaluate the inactivation of Cryptosporidium parvum by various disinfectants, including chlorine, ozone, and UV light. The assay was demonstrated to be as sensitive as animal infectivity assay, which has been considered the "gold standard" for assessing Cryptosporidium oocyst infectivity, and a valuable tool to evaluate inactivation of C. parvum by disinfectants. Bench-scale inactivation study showed that at the condition of $5^{\circ}C$ and pH 7.0, CT value of $1,250mg{\cdot}min/L$ by chlorine and $16mg{\cdot}min/L$ by ozone were required to achieve approximately 1.0 log inactivation of C. parvum, suggesting that even ozone could not be sufficient to inactivate C, parvum at low. temperature. Unlike chlorine and ozone, UV light is very effective to inactivate C. parvum, regardless of temperature. A UV light dose of 2 $mJ/cm^2$ provided at least 3 log inactivation of C. parvum.