• 제목/요약/키워드: Ozone variation

검색결과 189건 처리시간 0.023초

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

The Characterization of Surface Ozone Concentrations in Seoul, Koera

  • Heo, Jeong-Sook;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E3호
    • /
    • pp.129-142
    • /
    • 2002
  • This paper provides a long-term perspective for ozone concentrations at 20 national air quality monitoring sites in Seoul from 1989 to 1998, which were managed by the Korean Ministry of Environment. Ozone episodes occurred more frequently in the east areas (Bangi, Guui, Seongsu, and Ssangmun) than in the west area (Guro and Oryu). When an ozone episode happened, hourly ozone concentrations over 80 ppb continued for an average of 4.0 hours at all sites. Annual variations in daily mean and maximum oBone concentrations showed broadly consistent upward trends at Ssangmun and Gwanaksan. Monthly mean ozone concentrations were the highest from May to June and the 99$^{th}$ and 95$^{th}$ percentile levels appeared higher during June, July, and August. The diurnal patterns of hourly mean ozone levels in urban areas showed typical photochemical formation and destruction, while the flat diurnal shape before 1996 at Gwanaksan indicated few significant photochemical reactions due to a lack of precursors of ozone. The occurrence of ozone over 80 ppb was ascribed to meteorological conditions such as high temperature, strong solar radiation, low relative humidity, and low wind speed with winds most frequently in a westerly direction.

$Al_2O_3$ 세라믹 유전체 오존발생기의 방전면적 특성 (Discharge Area Characteristics of Ozonizer with $Al_2O_3$ Dielectric)

  • 박현미;송현직;이상근;임창호;윤병한;김종현;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2214-2216
    • /
    • 2005
  • This paper is researched discharge and ozone generation characteristics of ozonizer using $Al_2O_3$ Ceramic dielectric. The discharge characteristics with variation of the discharge electrode area is studied. The characteristics of ozone concentration. ozone generation and ozone yield were measured to discharge power, discharge electrode area and supplied gas flux for oxygen and air. The solubility of ozone for water concentrations and ozone generations proportional to discharge power and discharge electrode area. Ozone yield has slowly increase with Increasing discharge power at high flow-rate. As the result, the maximum values of ozone characteristics ozone generation and ozone yield, can be obtained 5817[ppm] and 36[g/kWh]. We make enough the ozone concentration as the air in the home. An electric discharge electrode area is apt to shrink gradually into a miniaturization trend of the ozonizer but the enlargement of the occurrence flight of the electric discharge area gives the characteristic enhance the aid in the identity condition through the structure improvement.

  • PDF

2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성 (Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan)

  • 전병일;오인보
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

주사바늘 전극형 오존발생기 특성 연구 (Observation and Characteristics of Ozonizer using Injection Needle Electrode)

  • 박현미;권영학;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.77-82
    • /
    • 2015
  • Ozone is a powerful disinfectant and oxidizing agent, and it is used in a wide range of applications, such as waste water treatment, food processing, etc.. There is also a great potential of using ozone in new emerging medical applications, such as ozone dentistry and ozone oxygen therapy. For these purposes, simple, small, compact and efficient sources of ozone are needed. In this study, in order to increase the current-voltage range of the discharge and to avoid the overheating of the gas in the ozonizer we suggested ozonizer of injection needle and plate electrode type(INP Type) with the gas through the needle. A ozonizer of INP type have been investigated by focusing on ozone concentration and yield according to flow rates and Gap of two electrodes. The results of studies of ozone production for DC corona discharge in oxygen at atmospheric pressure about the ozonizer of INP type. The ozone concentration and the generation yield increased as the gap of two electrodes and gas flow were decreased. Also, when the gap of two electrodes and gas flow with no change, the ozone concentration and generation yield each have variation of direct proportion and inverse proportion with discharge voltage.

오존처리에 의한 미국 사시나무의 엽록소 분해 (Ozone-Induced Chlorophyll Degradation in Populus tremuloides Michx. Foliage)

  • 신동일
    • 생명과학회지
    • /
    • 제6권4호
    • /
    • pp.299-303
    • /
    • 1996
  • 미국사시나무(Populus tremuloides)의 삽목개체에 오존이 엽록소함량의 변화에 미치는 영향을 조사하였다. 오존은 일일 6시간씩, 주 3일간 연속적으로 open-top chamber에서 fumigation 하였다. 오존처리는 괴사반점과 광범위한 chlorosis 등 잎 조직에 심각한 상해를 발생시켰다. 오존처리에 의한 엽록소의 분해는 완전히 성숙한 잎에서 현저하게 관찰되었으나 어린 잎에서는 분해가 거의 보이지 않았다. 오존처리에 대한 엽록소의 반응은 실험 전 기간에 걸쳐 모든 실험대상식물에 있어 일정한 양상을 보였다. 또한 clone 별로 오존 민감성에 따라 엽록소함량의 변화에 상당한 유전적 변이를 보였다.

  • PDF

과학 로켓 3호용 오존 측정기 개발 및 초기 모델 시험 결과 (DEVELOPMENT OF OZONE DETECTOR FOR KSR-III AND PRELIMINARY TEST RESULTS)

  • 황승현;김준;김준규;이수진;박정주;조광래
    • Journal of Astronomy and Space Sciences
    • /
    • 제17권2호
    • /
    • pp.277-284
    • /
    • 2000
  • KARI(Korea Aerospace Research Institute) has measured the ozone density profiles over the Korean Peninsular since the launch of the Korean Sounding Rocket-I (KSR-I) in 1993. The purpose of ozone measurements is to obtain the stratospheric and mesospheric vertical ozone density profiles over the Korean Peninsular with solar UV radiometers. With the visible channel of the radiometer, the attitude variation of the rocket was corrected and compensated. Developed system is based on ozone detector designs onboard the KSR-I and KSR-II. We discuss the development of ozone detector which will be onboard the KSR-III and its circuit and vibration test results for EM model.

  • PDF

MERRA-2 재분석자료를 활용한 적도 대류권계면층의 오존 수송 및 계절변동성 분석 (Analysis of the Ozone Transport and Seasonal Variability in the Tropical Tropopause Layer using MERRA-2 Reanalysis Data)

  • 류호선;김주완
    • 대기
    • /
    • 제30권1호
    • /
    • pp.91-102
    • /
    • 2020
  • MERRA-2 ozone and atmospheric data are utilized to test the usefulness of reanalysis-based tracer transport analysis for ozone in the tropical tropopause layer (TTL). Transport and mixing processes related to the seasonal variation of TTL ozone are examined using the tracer transport equation based on the transformed Eulerian mean, and the results are compared to previously proposed values from model analyses. The analysis shows that the seasonal variability of TTL ozone is mainly determined by two processes: vertical mean transport and horizontal eddy mixing of ozone, with different contributions in the Northern and Southern Hemispheres. The horizontal eddy mixing process explains the major portion of the seasonal cycle in the northern TTL, while the vertical mean transport dominates in the southern TTL. The Asian summer monsoon likely contributes to this observed difference. The ozone variability and related processes in MERRA-2 reanalysis show qualitatively similar features with satellite- and model-based analyses, and it provides advantages of fine-scale analyses. However, it still shows significant quantitative biases in ozone budget analysis.

전극 형태에 따른 평판형 오존발생기의 특성 (The Characteristics of Plate Type Ozonizer with Variation of Electrode Form)

  • 윤병한;이창호;우성훈;이광식
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.149-156
    • /
    • 2008
  • 최근 오존은 그 활용성을 인정받아 다양한 분야에서 사용되고 있으며, 그 수요 또한 계속 증가하는 추세이다. 이에 다양한 종류의 오존발생기가 연구되고 있으며, 고농도 및 고수율을 얻는 것이 연구목표라 할 수 있다. 본 논문에서는 전극 형태에 따른 평판형 오존발생기를 제작하여 원료가스의 유량 및 방전전력의 변화에 의한 오존생성농도, 오존생성량 및 오존생성수율 특성을 연구하였다.

Al2O3 유전체를 이용한 산소/공기 원료에 따른 오존발생기의 특성 (A Characteristic Analysis of Ozone Generator Using the Al2O3 Ceramic Dielectric According to Gas Type(O2/Air))

  • 박현미;송현직;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.76-81
    • /
    • 2014
  • The ozone generation is commonly made with silent discharge method using quartz glass dielectric. In this paper, using $Al_2O_3$ dielectric to instead of the traditional quartz glass dielectric to improve the system efficiency is presented. The dielectric was manufactured as tube shape (Internal diameter${\times}$ Outside diameter: $11{\times}15mm$) using 99% $Al_2O_3$ ceramic. The characteristics of dielectric discharge and ozone generation were studied of experiments with variation of discharge power, discharge electrode space and rate of flow for supplied gas ($O_2$/Air). As the experimental results, in the same discharge space, the ozone concentration continuously increased with input power increasing, and ozone yield increased until saturation happened. Also, the expended power increased with discharge space extended due to discharge power increased. In additional, the ozone concentration of oxygen ozone was higher than air that was observed when using oxygen ozone in proposed experiments.