• Title/Summary/Keyword: Ozone variation

Search Result 189, Processing Time 0.02 seconds

The Measures of Ozone Pollution: An Analysis of Ozone Concentration Data in USA

  • Kim, Hong-J.;Lovell, Sabrina J.;O'Farrell, John;Cho, Yong-Sung
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.47-53
    • /
    • 2008
  • In this study, we analyzed how ozone pollution could be differently measured and how these different measures varied year to year and across the ten most populated cities in the United States, from 1980 to 2000. Although peak values of ozone concentration have been significantly reduced in most polluted U.S. cities for the last 20 years, the annual average values of ozone concentration have not been lowered as much as peak values. Ozone concentration data for each city shows a unique pattern of distribution, central tendency, and also there is a wide variation among different ozone measures. Two different cities with the same annual mean concentration of ozone can experience very different distributions of ozone concentration within a year. Ozone measures also show a wide margin of variability as they are estimated from different ozone monitoring sites within each city. Ozone pollution statistics can be largely varied depending on the choice of measures, monitoring sites, and averaging time period. EPA's new ozone standard of 0.08 ppm averaged over an eight-hour appears to be more stringent than the current maximum ozone standard of 0.12 ppm averaged over one hour.

Anomaly Test for Ozone Concentration Data from National Air Monitoring Stations (오존 자동측정망 자료 중의 이상치 점검)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.139-150
    • /
    • 1999
  • The ozone concentrations measured at the National Air Monitoring Stations between 1990 and 1995 were reviewed to detect any anomalies in the measurements. By screening the cases, in which variation of the ozone concentration from the previous measured value is greater than 75ppb, 125 station-days were identified as the test cases for the anomaly test. Historical and parallel consistencies of the measured concentrations were examined by plotting data for each test case. The detected anomalies can be classified into four categories; single outliers, anomalous variations during the startup period, baseline rises, and fluctuations in th diurnal variations. Anomalies were detected in as many as 80 cases among 125 test cases. Because of these anomalies, the number of hours exceeding 100ppb in the areas other than the Greater Seoul Area(GSA) could decrease from 157 to 107. Further studies for developing the methodology for eliminating the abnormal monitoring data are warranted for the data from the National Air Monitoring Stations are official to the both inside and outside of the country.

  • PDF

Variations of the Polar Temperature in the Lower Stratosphere during 1955-2004

  • Choi, Wookap;Kim, Dongjoon
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2008
  • The lower-stratospheric polar temperature in winter and spring for both hemispheres is investigated based on the NCEP/NCAR 50-year reanalysis data with respect to the strength of the stratospheric eddy heat flux. Both the polar temperature and the eddy heat flux show significant variation on the decadal and year-to-year time scales except during the Southern Hemisphere winter. The year-to-year variation in the polar temperature is mainly determined by the eddy heat flux convergence. The eddy heat flux convergence is compared with the diabatic heating rate obtained from a two-dimensional model. Radiative heating caused by absorption of solar radiation is comparable to the heating caused by the eddy heat flux convergence in the Southern Hemisphere. The effect of ozone depletion on diabatic heating has been found to be secondary in the Northern Hemisphere, even in March 1997 when the record depletion of ozone took place.

A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application (오존의 정수처리 적용을 위한 오존소비인자에 관한 연구)

  • Kang, Tae-Hee;Oh, Byung-Soo;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.663-669
    • /
    • 2005
  • The aim of this study was to investigate the ozone decay pattern for the effective application of ozone in drinking water treatment. In order to measure the ozone decomposition in water, ozone measuring instrument was developed with flow injection analysis (FIA) method. From the result of continuous residual ozone concentration in water, it was confirmed that the ozone decay pattern was divided with instantaneous ozone demand(I.D) and pseudo first-order rate($k_c$) phases, which were influenced by the variation of ozone dose. The empirical model obtained from I.D and $k_c$ values enabled us to predict the residual ozone concentration according to the reaction time, showing the high correlation between model and experimental values. The concentration of OH radical and $R__{ct}$ could be indirectly measured by OH radical probe compound. In both I.D and $k_c$ phases, the production pattern of OH radical could be observed, which was also affected by the variation of ozone dose. Finally, it was confirmed that the ozone consumption rate was varied according to the each drinking water treatment process and seasoning. Therefore, the optimum position and dosage of ozone have to be selected by considering various factors.

A study on improvement of ozone process by Granular Activated Carbon (입상 활성탄을 이용한 오존공정의 개선에 관한 연구)

  • Lee, Yu-Mi;Rhee, Dong Seok
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.23-26
    • /
    • 2008
  • Ozone/GAC and ozone-GAC processes were introduced for treatment of humic acid, which is representative refractory organic compound. The treatment efficiencies of humic acid in each process were analyzed in pH variation, DOC removal, and $UV_{254}$ decrease. $UV_{254}$ decrease in all processes was comparatively high with efficiency over 92%. $UV_{254}$ decrease in ozone alone process was 85%. DOC removal in Ozone-GAC process was the highest with 75%. Removal by Ozone/GAC, Ozone alone processes were 71% and 33% respectively.

  • PDF

The Effects of Discharge Gap Variation for Ozone Generation Characteristics (방전간극변화가 오존생성특성에 미치는 영향)

  • 이상근;전병준;박용권;박원주;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.135-138
    • /
    • 2001
  • Recently, ozone is utilized In various fields and its needs are expanding. therefore, so many ozone generation methods have been reported in the latest years, its main purpose Is to get the high ozone concentration and to improve the ozone yield. One of them is a plate-type ozone generator. In this paper, the plate-type ozone generator is piled up many folds(3 and 5 electrodes). Ozone concentration and yield were investigated in accordance with power, quantity of supplied gas and gap spacing of plate electrodes.

  • PDF

The Characteristics of Ozone Generation for Dielectric Barrier Discharge with Discharge Area variation (방전면적에 따른 유전체장벽 방전에 의한 오존생성 특성)

  • Lee, Chang-Ho;Park, Soong-Gyu;Kim, Jong-Hyun;Lee, Hyun-Chul;Song, Hyun-Jig;Lee, Sang-Keun;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.379-380
    • /
    • 2008
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, glass and ceramic plate tyre ozonizer have been fabricated to investigate discharge parameter(input power, flow rate of supplied gas, electrode form, etc.) effect to discharge. And the conditions of discharge parameter have been investigated for optimum ozone generation. Ozone concentration is continuously increased with increasing input power for same discharge space, and ozone yield is also increased until maximum point after that it is saturated. Ozone concentration is inversely proportional to flow rate of supplied gas but ozone generation and ozone vield characteristics are improved.

  • PDF

Variation of Ozone Generation with change of Discharge Space Length (방전공간 구성에 따른 오조나이저 특성)

  • Cho, Hook-Hee;Kim, Young-Bae;Beo, Kil-Soo;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2144-2146
    • /
    • 2000
  • In this research, a ozone generation using a combined discharge method, in which a surface and a silent discharges are occur in discharge region simultaneously, is investigated experimentally. On our experiments, the combined discharge was confirmed, and the characteristics of the ozone generation were obtained. In this paper, the typical results about the ozone generation are described.

  • PDF

Photochemical Analysis of Ozone Levels in the Gulf of Gwangyang in the Spring and Summer of 2009 (2009년 봄, 여름철 광양만 지역 오존의 광화학적 특성 분석)

  • Shon, Zang-Ho;Song, Sang-Keun;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.161-176
    • /
    • 2010
  • We examined high ozone episodes observed during the intensive measurement periods (11 May~21 June and 30 July~11 August 2009) in the Gulf of Gwangyang. During that period, there were a few events (or days) in which 1 hr averaged ozone concentrations were greater than 100 ppbv. The analysis of ozone budget and photochemical characteristics related to the ozone production was carried out using a photochemical box model. Ozone sensitivity to $NO_x$ and VOCs was also examined in the study area during the measurement period. Diurnal variation of ozone during the episodes was similar to that of odd hydrogen radicals ($HO_2,CH_3O_2$, and $RO_2$), suggesting significant correlation with photochemical production of ozone during the episodes. In general, ozone concentration in the study area during the measurement period was sensitive to VOCs, whereas ozone was sensitive to $NO_x$ under certain conditions. Ozone sensitivity assessment using a radical budget analysis and $NO_x$/VOCs-control strategy was consistent with that using indicator species ($H_2O_2/HNO_3$ ratio).

Temporal Trends and Spatial Comparisons of Ozone Concentrations in Jinju (진주시 오존농도의 시간적 추이와 공간적 비교)

  • Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.761-769
    • /
    • 2010
  • Temporal trends of ozone concentration in Jinju were investigated by using observation data from 3 air quality monitoring stations for the period of 2004~2008. In addition, spatial comparisons of ozone concentration at Jeoguri, upwind and downwind directions of Jinju were investigated between May and September 2009. Annual mean exhibited increasing trends +1.7ppb/yr throughout the study period. In the case of diurnal variation, the lowest ozone concentration was shown from 7 am to 8 am and the highest around 4 pm. The ozone concentrations of Jeoguri station of the south coast were higher than Jinju. In particular, the upwind direction of Jinju had relatively hight ozone concentration