• Title/Summary/Keyword: Ozone variation

Search Result 189, Processing Time 0.021 seconds

Flux of Carbon Dioxide and Deposition Velocity of Ozone over Glycine max Canopy (대두 개체군에 있어서 $CO_2$$O_3$ 플럭스)

  • 김원식;이호준
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.39-43
    • /
    • 2000
  • Carbon dioxide (CO₂) and ozone (O₃) fluxes were measured over Glycine max canopy using the bowen ratio energy balance method at Fuchu - 20 km west of Tokyo, in late July and late September 1996. The CO₂, and O₃, fluxes were influenced by variation in leaf area index (LAI) during the measuring period. When LAI was more than 3.0, the CO₂ flux was found to be positively correlated with photosynthetically active radiation (PAR). The O₃, flux was always positive with an average deposition velocity for this case of about 0.5 mol m/sup -2/s/sup -1/. A positive correlation existed between the deposition velocity of O₃ and CO₂ during the period of LAI>2.0.

  • PDF

A Study on the Error Associated with Ventilation Rate Calculation Using Different Sampling Intervals (측정시간에 따른 거주주택의 환기량 계산 오류에 관한 연구)

  • 양원호;배현주;이기영;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.50-54
    • /
    • 2000
  • Ventilation rates can be measured directly by a tracer decay method, although little is known of the effects of different sampling intervals on decay rte calculations. This study determined variations in decay rates calculated by three techniques using residential ozone decay data. The calculation techniques were a regression technique, decay techniques using half-life and average-life, and finite difference techniques using two different time intervals. Variation associated with regression technique calculations for residential ozone decay rates based on data from both sample intervals were within 10% (2.81$\pm$1.88 hr-1). However, both half-life and finite difference technique calculations using a shorter-time interval were significantly different from those obtained with the regression technique(p<0.05). Therefore, the use of short sampling intervals in tracer decay may cause significant error in decay rate calculations.

  • PDF

Characteristics of long-term operated Electrostatic airclean filter for air-conditioner (장시간사용(長時間使用)한 공조용(空調用) 전기집진(電氣集塵)필터의 특성(特性))

  • Hong, Young-Ki;Kang, Kwang-Ok;Lee, Sung-Hwa;Son, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.453-455
    • /
    • 1995
  • In electrostatic airclean filter, the collection efficiency defends on particle charge in the ionizer section. The effect of electrostatic airclean filter condition (deposition of dust, variation of corona discharge current) on corona discharge characteristics was well studied. However, it seems not to be studied on corona discharge characteristics of electrostatic airclean filter respect to contaminated electrode which is caused by practical use. In this paper, Long-term(60days) effects are studied experimentally by two methods. The one is ozone concentration, the other is collection efficiency. Generation of ozone level was increased but collection efficiency was slightly reduced in long-term used electrostatic airclean filter.

  • PDF

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

A Study on Discharge Characteristics in Flowing Gas at High Voltage Nozzle (고전압(高電壓) Nozzle 에서 유출(流出)하는 기체(氣體)의 방전특성(放電特性)에 관한 연구(硏究))

  • Song, Hyun-Jig;Kim, Sang-Ku;Jeun, Young-Ju;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.563-565
    • /
    • 1993
  • This paper describes ozone concentration and discharge characteristics in flowing $O_2$ with variation of Re at high voltage nozzle(HVN). HVN type ozonizer is equipped with ten nozzle. The important conclusions obtained from this paper are as follows. For constant pulse width(Pw) and pulse frequency(Pf) the more Re increases, the higher corona onset voltage(Vc) rise. Vc is inversely proportional to Pw and Pf. Ozone concentration($O_{3con}$) increases with less Re for constant Pw and Pf. $O_{3con}$ increases with less Pw. $O_{3con}$ is proportional to Pf.

  • PDF

Response of Ozone Sensitivity in Open-Pollinated Families of Pinus densiflora Seedlings (소나무 풍매차대묘(風媒次代苗)의 가계간(家系間) 오존에 대한 민감성(敏感性) 반응(反應))

  • Lee, Jae-Cheon;Oh, Chang-Young;Han, Sim-Hee;Kim, Jang-Su
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.191-196
    • /
    • 2005
  • This studies were conducted to compare ozone sensitivity among half-sib families of Japanese red pine (Pinus densiflora S. et Z.). 90 families were exposed in walk-in type chambers to charcoal-filtered air and 100 ppb ozone for 8 hours daily, 5 consecutive months. We surveyed the foliar injury, Relative DRC (diameter at root collar) growth and relative dry weight after fumigation. After 5 months of exposure, foliar injury ranged from 1.9% at tolerant group to 15.2% at sensitive group. Relative DRC growth rates showed increased 12% at tolerant group, but reduced 23% at sensitive group. Total dry weight increased 17% at tolerant group, otherwise reduced by 33% at sensitive group, relative to the control. The root biomass showed more sensitive than the other part biomass. On the basis of the results of these screening studies, families Kangwon 04, 16, 26, 27 and 73 were determined to be tolerant; Kangwon 40, 52, 83, Gyeonggi 01 and Gyeongbuk 20 to be sensitive to ozone. Considerable genetic variation in ozone responses occurred, as shown by differences in sensitivities among families and among groups. These results indicate that tolerant groups of P. densiflora exhibited a high degree of resistance to ozone pollution injury.

Impacts of Local Meteorology caused by Tidal Change in the West Sea on Ozone Distributions in the Seoul Metropolitan Area (서해 조석현상에 따른 국지기상 변화가 수도권 오존농도에 미치는 영향)

  • Kim, Sung Min;Kim, Yoo-Keun;An, Hye Yeon;Kang, Yoon-Hee;Jeong, Ju-Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.3
    • /
    • pp.341-356
    • /
    • 2019
  • In this study, the impacts of local meteorology caused by tidal changes in the West Sea on ozone distributions in the Seoul Metropolitan Area (SMA) were analyzed using a meteorological model (WRF) and an air quality (CMAQ) model. This study was carried out during the day (1200-1800 LST) between August 3 and 9, 2016. The total area of tidal flats along with the tidal changes was calculated to be approximately $912km^2$, based on data provided by the Environmental Geographic Information Service (EGIS) and the Ministry of Oceans and Fisheries (MOF). Modeling was carried out based on three experiments, and the land cover of the tidal flats for each experiment was designed using the coastal wetlands, water bodies (i.e., high tide), and the barren or sparsely vegetated areas (i.e., low tide). The land cover parameters of the coastal wetlands used in this study were improved in the herbaceous wetland of the WRF using updated albedo, roughness length, and soil heat capacity. The results showed that the land cover variation during high tide caused a decrease in temperature (maximum $4.5^{\circ}C$) and planetary boundary layer (PBL) height (maximum 1200 m), and an increase in humidity (maximum 25%) and wind speed (maximum $1.5ms^{-1}$). These meteorological changes increased the ozone concentration (about 5.0 ppb) in the coastal areas including the tidal flats. The increase in the ozone concentration during high tide may be caused by a weak diffusion to the upper layer due to a decrease in the PBL height. The changes in the meteorological variables and ozone concentration during low tide were lesser than those occurring during high tide. This study suggests that the meteorological variations caused by tidal changes have a meaningful effect on the ozone concentration in the SMA.

Numerical Study on the Impact of Regional Warming on the Meterological Field and Ozone Concentration over the South-Eastern Part of the Korean Peninsula (기후변화에 따른 기온상승이 한반도 동남지역 국지 기상장과 오존 분포에 미치는 영향에 관한 수치모의)

  • Jeong, Yeo-Min;Lee, Hwa-Woon;Lee, Soon-Hwan;Choi, Hyun-Jung;Jeon, Won-Bae
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1431-1445
    • /
    • 2010
  • In order to clarify the impact of regional warming on the meteorological field and air quality over southeastern part of Korean Peninsula, several numerical experiment were carried out. Numerical models used in this study are WRF for the estimate the meteorological elements and CMAQ for assessment of ozone concentration. According to the global warming impact, initial air temperature were changed and its warming rate reach at 2 degree which was based on the global warming scenarios provided by IPCC. The experiments considering the global warming at initial stage were presented as case T_UP. Air temperature over inland area during night time for case T_UP is higher than that for Base case. During time since the higher temperature over inland area is maintained during daytime more intensified sea breeze should be induced and also decrease the air temperature in vicinity of coast area. In case of T_UP, high level concentrations ozone distribution area was narrowed and their disappearance were faster after 1800LST. As a results, wind and temperature fields due to the global warming at initial stage mainly results in the pattern of ozone concentration and its temporal variation at South-Eastern Part of the Korean Peninsula.

Characteristics of Environmental Solar Ultraviolet Irradiance

  • Sasaki, Masako;Oyanagi, Takehiko;Takeshita, Shu
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.154-157
    • /
    • 2002
  • Direct, continuous, and accurate measurements of solar ultraviolet irradiance (290-400 nm: UVR) have been carried out since 1990, by using both band-spectral ultraviolet-B (290-320 nm: UV-B) and ultraviolet-A (320-400 nm: UV-A) radiometers at Tokai University in Hiratsuka, Japan (35$^{\circ}$N, 139$^{\circ}$E). From our observations, the following findings are provided: 1) an increasing trend in solar UV -B from Oct. 1990 to Sept. 2000; 2) a regional comparison of solar UVR in Japan; 3) the distinct characteristics of UV-B and UV-A irradiance, such as diffuse property, daily and seasonal variation; and 4) human body protection against solar UVR. An increasing 10-year trend in global solar UV - B in Hiratsuka corresponded to a decrease in the total ozone amount measured at Tsukuba (36$^{\circ}$N, 140$^{\circ}$E), giving supportive evidence for a direct link between these two parameters. Furthermore, a strong correlation was found between solar UV-B and total ozone amount from results of UVR measurements at four Tokai University monitoring stations dispersed throughout Japan. Additional results revealed different diffuse properties in global solar UV and in global solar total (300-3000 nm: Total) irradiances. For example, in the global UVR, the diffuse component was dominant: about 80 % independent of weather, with more than 60 % of global UV-B, and more than 50% of global UV-A with even a cloudless clear sky. On the other hand, the portion of the diffuse in the global total irradiance was very low, less than 10 % on a cloudless clear day. Daily and seasonal variations of UV -B and UV -A irradiances were found to be quite different, because of the marked dependence of UV -B irradiance on the atmospheric ozone amount. Moreover, UV -B irradiance showed large daily and seasonal variations: the ratio between maximum and minimum irradiances was more than 5. In contrast, the variation in UV-A was small: the ratio between maximum and minimum was less than 2. Three important facts are proposed concerning solar UVR protection of the human body: 1) the personal minimal erythema dose (MED); 2) gender based difference in MED values; and 3) proper colors for UVR protective clothing.

  • PDF

Characteristics of long-term behavior of VOC species in Korea - PAMS data analysis (우리나라 휘발성유기화합물 화학종의 장기 거동 특성 - 광화학오염물질 측정자료 분석)

  • Park, Ji Hoon;Kang, Soyoung;Song, In-Ho;Lee, Dong-Won;Cho, SeogYeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.56-75
    • /
    • 2018
  • Korean Photochemical Assessment Monitoring Stations (PAMS) have been established since the late 2001 to monitor ambient air concentrations of VOC species, which would enhance understanding photo-chemical formation of ozone and subsequently contribute to developing efficient ozone control strategies. The present study aims at identifying major VOC species and examining their trends by analyzing PAMS monitoring data collected from the year 2006 to 2016. All the 18 PAMS sites operated by the Ministry of Environment were included in the study. PAMS monitored the 56 target VOC species, which are classified into four groups, alkenes, lower alkanes ($C{\leq}3$), higher alkanes ($C{\geq}4$), aromatics. The higher alkanes and aromatics dominated over the lower alkanes and alkenes in the type 2 and 3 PAMS sites except Joongheung site. N-butane was a major alkane species, toluene was a major aromatic species and most of VOCs showed decreasing trends in these sites. On the other hand, only the alkenes showed decreasing trends at the Joongheung site in Yeosu. Major sources of abundant species such as ethane, propane, n-butane, toluene were estimated by analyzing seasonal variations, correlation with other VOC species, and emission profiles. A major source of n-butane was identified as LPG cars, while major sources of toluene varied considerably from one site to another. The lower alkanes were composed of ethane and propane, both of which showed a strong seasonal variation, low in the summer and high in the winter, indicating that a major source might be the heating by gaseous fuels. Ozone formation potentials of VOC species were evaluated by applying MIR and POCP to the measured VOC species concentrations. Toluene contributed the most to total ozone forming potentials followed by m,p-xylene for all the type 2 and 3 PAMS sites except for two sites in Yeosu-Gwangyang. Ethylene and propylene were the first and second contributors to total ozone forming potentials at Joongheung site in Yeosu.