• Title/Summary/Keyword: Ozone treatment system.

Search Result 119, Processing Time 0.029 seconds

A Study on the Decolorization of Reactive Dyes by Using Ozone Treatment (오존에 의한 반응성 염료의 탈색에 관한 연구)

  • Lee, Mun-Soo
    • The Journal of Natural Sciences
    • /
    • v.9 no.1
    • /
    • pp.9-17
    • /
    • 1997
  • We studied on the decoloring efficiency of a dying and finishing industrial wastewater containing reactive dyes in the ozone treatment system. The wastewater containing reactive dyes improved the decolorization by the ozone oxidation. In order to determine the optical conditions for ozonation, various operation factors such as initial wastewater concentrations, pH, temperature, and ozone dose were evaluated. Ozone utilization rate was improved in general with the increase of initial concentration of wastewater. And the decolorization speed or reactive dyes was more decreased in deep color of blue series than in light color such as yellow series. The colorization of wastewater containing reactive dyes was changed step through midle color depending upon increasing of ozone treated time. The efficiency of decolorization for wastewater was improved with the pH increased and the temperature of ozone treatment system decreased.

  • PDF

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

A Study on the Characteristics of Ozonizers and Implementation of a Monitoring System (오존발생기의 특성 연구 및 모니터링 시스템 구축)

  • 김용철;김규식;최주엽
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.460-466
    • /
    • 2001
  • The oxidizing power of ozone is the greatest of all commercially available oxidizers and thus ozone is taking the place of chlorine for water treatment. For energy-effective treatment of water, ozone should be generated in high concentration. A silent glow discharge ozonizer is high effective in industrial aspect and thus is the most widely used. We found that the key parameters associated with the ozone generation rate are the driving voltage of the discharger, the discharge rate and the temperature of the ozone generation tube. For an easy control of these parameters, we build a monitoring system with graphical user interface. This system is based on Windows-98 PC, programmed with C++ and LabView.

  • PDF

A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation (오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구)

  • 김민규;권재현;조영하;이진애;권오섭
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.

Livestock Wastewater Treatment Using the DOF and PO2 System with High Concentration of Ozone (고농도 오존을 적용한 DOF와 PO2 시스템의 축산폐수처리)

  • Lee, Byoung-Ho;Kim, Sung-Hyuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1162-1167
    • /
    • 2005
  • Livestock wastewater is known to be very difficult to treat because it contains highly non-biodegradable organic material. Thus the DOF(Dissolved Ozone Flotation) system and the PO2(Pressurized Ozone Oxidation) system were built at the livestock wastewater treatment plant, and characteristics of treatments were investigated in this paper. Suspended Solids(SS) removal efficiency was over 94% by DOF system. 90% of $COD_{Mn}$ was removed, from 620 mg/L down to 63 mg/L by the DOF-PO2 system. During the period of operation, $SCOD_{Cr}$ was removed an average of 82%, from 890 mg/L down to 160 mg/L. 96% of UV-254 absorbance was also removed. TP removal efficiency was over 98%, from 27 mg/L to 0.35 mg/L, and TN was also removed 68% along with suspended solids. It was possible to meet effluent standards of the livestock wastewater treatment plant by the DOF-PO2 system along with biological treatment.

A Study on the Bleaching and Dyeing Properties of Cotton Fabrics Treated with Ozone($O_{3}$) (Ozone($O_{3}$)을 이용한 선직물의 표백과 양색성에 관한 연구)

  • Cho, Hwan;Woo, Hyun-Seok;Jung, Hee-Chun
    • Textile Coloration and Finishing
    • /
    • v.7 no.1
    • /
    • pp.32-42
    • /
    • 1995
  • In order to reduce the amount of waste water generated from textile dyeing process and processing water, cotton fabric was bleached with ozone in ozone/water contact system, and dyed. The results obtained from the measurement of whiteness, reflectance, tensile strength, color difference, and K/S value of treated samples were as follow : 1) In ozone bleaching, factors affect whiteness most are treatment time and ozone dosage. As treatment time is lengthened, whiteness increases. Futhermore, bleaching effect is high in acidic treatment, but low in alkaline treatment. 2) As bleaching goes on, maximum absorption wave length shifts to shoter wavelengths. 3) As treatment time is lengthened or pH of treatment is low, tensile strenth of treated fabric decrease. 4) In all cases, color difference of dyed cotton fabrics in above 2% o.w.f. dyestuff concentration don't go beyond 1∼2 AN unit, compared with standard.

  • PDF

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

The Development of Ozone Generation System with High Capacity for Advanced Water Treatment Process (고도정수처리용 대용량 오존발생시스템 개발)

  • Lee, Hyeong-Ho;Kim, Young-Bae;Seo, Kil-Soo;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2001-2003
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. Ozone generation system is composed of ozone generation device, air or oxygen supply device and high voltage apply device. In this paper, commercial frequency was applied to the wire typed conductor. The ozone concentration was measured with air or oxygen as a supplied gas, which can be used as basic data for the development of ozonizer system.

  • PDF