• Title/Summary/Keyword: Ozone supply methods

Search Result 14, Processing Time 0.02 seconds

Ozone Condensation and Stable Supply by an Adsorption Method

  • Yang, Seong-Ho;Park, Yong-Pil;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.121-125
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Dentisity Estimation and Stable Supply in the Growth Process of BSCCO Thin Film

  • Lee, Hee-Kab;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.45-49
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Density Estimation and Stable Supply in the Thin Film Growth

  • Lim, Jung-Kwan;Park, Yong-Pil;Oh, Geum-Gon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.42-45
    • /
    • 2001
  • An ozone condensation system is evaluated from the viewpoint of an ozone supplier for Bi-superconductor thin film growth. An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Generation Characteristics with Pulse Power Supply (펄스전원을 이용한 오존발생특성)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hong-Sik;Kim, Hag-Gyu;Lee, Jong-Min
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1837-1839
    • /
    • 2003
  • Recently deep interests have been paid on the effective generation of ozone, which has been widely used for water treatment, deoderization, color removal and chemical processing of exhausted smoke. The silent discharge reaction has been proposed as the most effective in the many ozone generation methods by electric discharge, because silent discharge excel others in the condition of high ozone generation yield and low power consumption. In this paper, ozone water generated system measure with silent discharge characteristics and pulsed power supply.

  • PDF

The Study of Particle Removal Efficiency (PRE) with Alkaline Ozonized Water (알칼라인 오존수를 아용한 입자제거에 관한 연구)

  • Lee, Seung-Ho;Kim, Tae-Gon;Lee, Jae-Hwan;Park, Jin-Goo;Bae, So-Ik;Lee, Gun-Ho;Kim, In-Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.362-363
    • /
    • 2006
  • Ozonized DI water was supplied to make alkaline cleaning solutions to replace SCI chemicals in a bath with and without recirculation. With recirculation, low dissolved ozone and low pH cause lower particle removal efficiency (PRE) of 75%. However, direct supply of ozonized water with $NH_4OH$ to a bath without recirculation resulted in higher PRE over 93 %.

  • PDF

Discharge and Ozone Generation Characteristics of a Co-axial Cylinder Type Ozonizer in Accordance with Varying Discharge Gap (방전갭 변화에 따른 동축 원통형 오존발생기의 방전특성과 오존생성특성)

  • 이상근;전병준;박용권;이광식;최상태;송현직
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.103-110
    • /
    • 2001
  • Recently, ozone is utilized in various fields and its needs are expanding. Therefore, so many ozone generation methods have been reported in the last year, its main purpose is to get the high ozone concentration and to improve the ozone yield one of them is a Co-axial cylinder-type ozonizer. In this paper, a new ozonizer, which is using radio-frequency power supply, is fabricated to investigate discharge characteristics and ozone generation characteristics in accordance wish variation of grip spacing of electrodes.

  • PDF

A Study on the Distribution Characteristics of Bromide and Bromate in Drinking Water in Northern Gyeonggi Area (경기북부지역 먹는 물 중 브롬이온 및 브롬산염의 분포특성에 관한 연구)

  • Jung, Jong-Pil;Choi, Si-Rim;Ryu, Hyeung-Rial;Park, Gyoung-Su;Song, Hee-Il;Lee, Hyun-Jin;Jo, Mi-Hyun;Oh, Jo-Gyo;Yoon, Mi-Hye
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.244-249
    • /
    • 2018
  • Objectives: The purpose of this study was the investigation of bromide and bromate in drinking water of water supply plants, mineral springs and small water supply system located in northern area of Gyeonggi province. Methods: Analytical method was based on EPA 326.0 to use Postcolumn reaction (PCR). The instrument was 887 professional UV/VIS detector IC manufactured in Metrohm. Results: Bromate was detected at $0.5{\sim}2.4{\mu}g/L$ in tap water from 5 water supply plants. These plants were used as disinfection method for sodium hypochlorite and on-site chlorine that causes generate bromate as a by products even if not used ozone. Conclusions: The bromate was detected up to $2.5{\mu}g/Lin$ drinking water in northern Gyeonggi area that showed within $10{\mu}g/L$ for standard of tap water. However, the continuous monitoring of bromate is necessary in drinking water.

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

Frequency control method of ozonator power supply (오존발생기 구동장치의 주파수제어에 관한 연구)

  • 최규남
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.887-893
    • /
    • 1999
  • The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

  • PDF

Efficient Simulation Method for Dielectric Barrier Discharge Load

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.188-196
    • /
    • 2004
  • The dielectric barrier discharge is recognized as one of the efficient methods of ultraviolet light generation and ozone production. As well, it is widely utilized for gaseous wastes neutralization and other technological processes in industry. This electrochemical reaction is electrically equivalent to a nonlinear capacitive load that represents some difficulties for designing the power supply. Therefore, a conventional power supply is designed for a drastically simplified model of the load and generally is not optimal. This paper presents a fast simulation approach for the nonlinear capacitive model representation of the dielectric barrier discharge load lamp. The main idea of the proposed method is to use analytical solutions of the differential state equations for the load and find the unknown initial conditions for the steady state by an optimization method. The derived expressions for the analytical solutions are rather complicated, however they greatly reduce the calculation time, which make sense when a deeper analysis is performed. This paper introduces the proposed simulation method and gives some examples of its application such as estimation of the load equivalent parameters and load matching conditions.