• Title/Summary/Keyword: Oxygen flow rate

Search Result 689, Processing Time 0.026 seconds

Gas Adsorption Characteristics of by Interaction between Oxygen Functional Groups Introduced on Activated Carbon Fibers and Acetic Acid Molecules (활성탄소섬유에 도입된 산소작용기와 초산 분자와의 상호작용에 따른 가스 흡착 특성)

  • Song, Eun Ji;Kim, Min-Ji;Han, Jeong-In;Choi, Ye Ji;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.30 no.2
    • /
    • pp.160-166
    • /
    • 2019
  • In this study, oxygen functional groups were introduced on activated carbon fibers (ACFs) by oxygen plasma treatment to improve the adsorption performance on an acetic acid which is a sick house syndrome induced gas. The active species was generated more as the flow rate of the oxygen gas increased during the plasma treatment. For this reason, the specific surface area (SSA) of the ACFs decreased with much more physical and chemical etching. In particular, the SSA of the sample (A-O60) injected with an oxygen gas flow rate of 60 sccm was reduced to about $1.198m^2/g$, which was about 6.95% lower than that of the untreated samples. On the other hand, the oxygen content introduced into the surface of ACFs increased up to 35.87%. Also, the adsorption performance on the acetic acid gas of the oxygen plasma-treated ACFs was improved by up to 43% compared to that of using the untreated ACFs. It is attributed to the formation of the hydrogen bonding due to the dipole moments between acetic acid molecules and oxygen functional groups such as O=C-O introduced by the oxygen plasma treatment.

Preparation and characterization of$PbTiO_3$ thin films deposited on Si(100) substrate by MOCVD (MOCVD 법에 의해 Si(100) 기판 위에 제조된 $PbTiO_3$ 박막의 증착 특성)

  • 김종국;박병옥
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.1
    • /
    • pp.34-38
    • /
    • 1999
  • $PbTiO_3$(PT)thin films were prepared by simultaneous of $TiO_2$ and PbO on Si(100) substrate using metaloganic chemical vapor deposition (MOCVD). Titanium tetra-isopropoxide (TTIP) and $Pb(TMHD)_2$were used as source materials. As evaporation temperature and flow rate of TTIP were examined the crystal structure of PT thin films using XRD with setting deposition temperature, flow rate of Pb, and total flow rate of $520^{\circ}C$, 30 sccm, and 750 sccm, respectively. PT thin films could be deposited under 48~$50^{\circ}C$ and 18~22sccm of evaporation temperature and flow rate of TTIP, respectively. It was found that lead, oxygen, and silicon diffused at the iaterface between the film and the substrate.

  • PDF

Wear Property of Diamalloy-4006 Coating Prepared by OCP HVOF Thermal Spraying (최적 고속화염용사법으로 제조된 Diamalloy4006 코팅의 내마모 특성)

  • Joo, Yunkon;Yoon, Jaehong;Jung, Yeongil;Lee, Jehyun
    • Korean Journal of Materials Research
    • /
    • v.25 no.9
    • /
    • pp.442-449
    • /
    • 2015
  • The effects of coating parameters were investigated in wear resistance coatings of Diamalloy-406 on Inconel 718 to obtain an optimum coating condition by high velocity oxy-fuel spraying. The coating parameters, the flow rates of source gases (hydrogen and oxygen), the powder feed rate, and the spray distance, were designed by the Taguchi method. The optimal conditions were determined: oxygen flow rate 34 FRM, hydrogen flow rate 57 FRM, powder feed rate 35 g/min, and spray distance 7 inch. Friction coefficients of the coating and the substrate decreased with an increasing sliding surface temperature from $25^{\circ}C$ to $450^{\circ}C$. The friction coefficient of Diamalloy-4006 coating decreased as the sliding surface temperature increased from $0.43{\pm}0.01$ at $25^{\circ}C$ to $0.29{\pm}0.01$ at $450^{\circ}C$. The wear trace and wear depth of the coating were smaller than the substrate at all temperatures tested. The relationship between spray parameters and wear resistance was discussed extensively, based on the measured roughness, hardness, and porosity in each coating.

Effect of Process Parameters on the Hardness and Wear Rate of Thermal Sprayed Ni-based Coatings (니켈기 경질 용사코팅의 경도 및 마모율에 미치는 공정조건의 영향)

  • Kim, K.T.;Kim, J.D.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • The various process parameters of thermal spray process affects on quality of Ni-based coatings. Thus, there is need to analyze the effect of process parameters on quality of Ni-based coatings. In this paper, the effects of process parameters on hardness and wear rate of Ni-based coatings were investigated using 4 design of experiments. First, the Ni-based coatings were fabricated according to $L_9(3^4)$ orthogonal array. The hardness tests and the wear tests were performed on the Ni-based coatings. The analysis of variance for the hardness and wear rate were carried out. As a results, the acetylene gas flow and the powder feed rate were identified as main factors effected on the hardness and the oxygen gas flow and the acetylene gas flow were identified as main factors effected on the wear rate. The full factorial experiments design with different levels was applied for investigation of effect of these main factors.

A Study on the effect of hydrogen flow rate and $CH_4$ concentration in deposition of the diamond thin films by MWPECVD (MWPECVD법에 의한 Diamond합성에 있어서 수소류양과 메탄농도의 영향)

  • Cho, J.K.;Park, S.T.;Park, S.H.;Geun, H.K.;Park, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1493-1495
    • /
    • 1994
  • Study on the effect of hydrogen flow rate and $CH_4$ concentration in deposition of the diamond thin films by MWPECVD diamond thin films were deposited on Si substrate from $CH_4-H_2-O_2$ system by MWPE CVD, and identified by SEM, XRD and Raman spectroscopy. The flow rate of hydrogen didn't affect the surface morphology and crystallity of diamond thin films, but did slightly affect growth rate. When the concentration of oxygen was fixed at 40%, the growth rate and crystallity of diamond thin films were gradually improved according to increasment of concentration of $CH_4$ but growth rate of the thin films showed peak at 7% and the crystallity showed peak at 6%.

  • PDF

Approximated Solution of Model for Three-Phase Fluidized Bed Biofilm Reactor in Wastewater Treatment

  • Choi Jeong-Woo;Min Junhong;Lee Won-Hong;Lee Sang Baek
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.1
    • /
    • pp.65-70
    • /
    • 2000
  • An approximated analytical solution of mathematical model for the three phase fluidized bed bioreactor (TFBBR) was proposed using the linearization technique to describe oxygen utilization rate in wastewater treatment. The validation of the model was done in comparison with the experimental results. Satisfactory agreement was obtained in the comparison of approximated analytical solution and numerical solution in the oxygen concentration profile of a TFBBR. The approximated solutions for three modes of the liquid phase flow were compared. The proposed model was able to predict the biomass concentration, dissolved oxygen concentration the height of efficient column, and the removal efficiency.

  • PDF

Electrical and Optical Properied of Tin Oxide Films Prepared by Ozone Assisted-MOCVD (Ozone Assisted-MOCVD로 제작된 산화주석막의 전기적 광학적 특성)

  • 배정운;이상운;송국현;박정일;박광자;염근영
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.2
    • /
    • pp.109-116
    • /
    • 1998
  • Highly transparent conductive pure and fluorine-doped tin oxide(FT0, $SnO_2$ : F) films have been prepared by low pressure metal organic chemical vapor deposition (LP-MOCVD) from various mixtures of tetramethyitin(TMT) with oxygen or oxygen containing ozone. The properties of TO films have been changed with the variation of gases, flow rate, and substrate temperature. The nsing of oxygen containing ozone instead of pure oxygen, reduced substrate temperature by 100-$150^{\circ}C$ while maintaining same thickness. The films prepared by using ozone showed the resistivity in the range from $10^~2$ to $10^{~3}\Omega$cm, and the mobiiity from 10 to $14\textrm{cm}^2$/Vs. Fluorine-doped tin oxide films had properties such as the resistivity about $10^{-4}\Omega$cm, and the mobility from 14 to $19\textrm{cm}^2$/Vs.

  • PDF

A Study About the Effect of Supercharging and Intake Charge on Engine Performance in Spark Ignition Gasoline Engine (SI 가솔린 엔진의 과급 및 흡기가 엔진 성능에 미치는 영향에 대한 연구)

  • Kim, Gi-Bok;Jin, Seok-Jun;Kim, Chi-Won;Yoon, Chang-Sik;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.2
    • /
    • pp.110-118
    • /
    • 2015
  • In this study, it is designed and used the test engine bed which is installed with turbocharger, and in addition to equipped using by oxygen adder. It has been controlled the oxygen volumetric fraction of intake air chrge, and supercharged flow rate into the cylinder of SI 4-stroke engine, and then, has been analyzed engine performance, combustion characteristics, and exhaust emission as analysis parameters. The tested parameters were the oxygen fraction and the variation of engine speed and air-fuel ratio.

Phenol Removal Using Oxygen-Plasma Discharge in the Water (산소-플라즈마 방전을 이용한 수중의 페놀 제거)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.915-923
    • /
    • 2013
  • Decomposition of non-biodegradable contaminants such as phenol contained in water was investigated using a dielectric barrier discharge (DBD) plasma reactor in the aqueous solutions with continuous oxygen bubbling. Effects of various parameters on the removal of phenol in aqueous solution with high-voltage streamer discharge plasma are studied. In order to choose plasma gas, gas of three types (argon, air, oxygen) were investigated. After the selection of gas, effects of 1st voltage (80 ~ 220 V), oxygen flow rate (2 ~ 7 L/min), pH (3 ~ 11), and initial phenol concentration (12.5 ~ 100.0 mg/L) on phenol degradation and change of $UV_{254}$ absorbance were investigated. Absorbance of $UV_{254}$ can be used as an indirect indicator of phenol degradation and the generation and disappearance of the non-biodegradable organic compounds. Removal of phenol and COD were found to follow pseudo first-order kinetics. The removal rate constants for phenol and COD of phenol were $5.204{\times}10^{-1}min^{-1}$ and $3.26{\times}10^{-2}min^{-1}$, respectively.

Optimal DO Setpoint Decision and Electric Cost Saving in Aerobic Reactor Using Respirometer and Air Blower Control (호흡률 및 송풍기 제어 기반 포기조 최적 DO 농도 설정과 전력 비용 절감 연구)

  • Lee, Kwang Su;Kim, Minhan;Kim, Jongrack;Yoo, Changkyoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.581-586
    • /
    • 2014
  • Main objects for wastewater treatment operation are to maintain effluent water quality and minimize operation cost. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. The oxygen uptake rate (OUR) is real-time measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO set-point needed for the micro-organism is suggested based on real-time measurement of oxygen uptake of micro-organism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal set-point decision system by providing the necessary oxygen supply requirement to the micro-organisms coping with the variations of influent loading.