• Title/Summary/Keyword: Oxygen Consumption Rate

Search Result 392, Processing Time 0.025 seconds

Pulse wave analysis system using wrist type oximeter for u-Health service (u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

Thin Films Deposition Study Using Plasma Enhanced CVD with Low Dielectric Materials DEMS(diethoxymethlysiliane) below 45nm (PE-CVD를 이용한 45nm이하급 저유전물질 DEMS(Diethoxymethylsiliane) 박막증착연구)

  • Kang, Min-Goo;Kim, Dae-Hee;Kim, Yeong-Cheol;Seo, Hwa-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.148-148
    • /
    • 2008
  • Low-k dielectric materials are an alternative plan to improve the signal propagation delay, crosstalk, dynamic power consumption due to resistance and parasitic capacitance generated the decrease of device size. Now, various materials is studied for the next generation. Diethoxymethlysiliane (DEMS) precursor using this study has two ethoxy groups along with one methyl group attached to the silicon atoms. SiCOH thin films were deposited on p-type Si(100) substrate by Plasma Enhanced Chemical Vapor Deposition (PECVD) using DEMS. In this study, we studied the effect of oxygen($O_2$) flow rate for DEMS to characteristics of thin films. The characteristics of thin films deposited using DEMS and $O_2$ evaluated through refractive index, dielectric constant(k), surface roughness, I-V(MIM:Al / SiCOH / Ag), C-V(MIM), deposition rate.

  • PDF

Pysiological Responses of Diploid and Triploid Far Eastern Catfish, Silurus asotus to Water Temperature Stress

  • Lee, Hyo Bin;Kim, Dong Soo;Gil, Hyun Woo;Park, In-Seok
    • Development and Reproduction
    • /
    • v.22 no.2
    • /
    • pp.165-174
    • /
    • 2018
  • The aim of study is to contribute to this knowledge-base by investigating the respiratory function, the metabolic rate and the difference of physiological responses un-der low water temperature ($20^{\circ}C{\rightarrow}15^{\circ}C$) stress be-tween diploid and triploid far eastern catfish, Silurus asotus. During the 48 hrs of water temperature stress exposure time, the respiratory frequencies, $CO_2$ and ${NH_4}^+$ concentrations of diploid had higher values than those of triploid (p<0.05). However, pH of triploid was higher than those of diploid (p<0.05), and oxygen consumption rate was not different between diploid and triploid (p>0.05). The level of plasma cortisol and plasma glucose of triploid was lower than those of the diploid (p<0.05). However, in case of lactic acid, there were not significant between triploid and diploid (p>0.05). These results suggest that diploid was more sensitive for low water temperature stress response than triploid in this species.

A study of decomposition of sulfur oxides using Composite catalyst by plasma reactions (복합촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구)

  • Woo, In-Sung;Hwang, Myung-Hwan;Kim, Da-Young;Kim, KwanJoong;Kim, Sung-Tea;Park, Hwa-Young
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.655-668
    • /
    • 2013
  • In this study, a combination of the plasma discharge in the reactor by the reaction surface discharge reactor complex catalytic reactor and air pollutants, hazardous gas SOx, change in frequency, residence time, and the thickness of the electrode, the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. 20W power consumption 10kHz frequency decomposition removal rate of 99% in the decomposition of sulfur oxides removal experiment that is attached to the titanium dioxide catalyst reactor experimental results than if you had more than 5% increase. If added to methane gas was added, the removal efficiency increased decomposition, the oxygen concentration increased with increasing degradation rate in the case of adding carbon dioxide decreased.

  • PDF

Water and Sediment Characteristics in the Shellfish Farms of the Western Part of Jinhae Bay

  • Choi Hee Gu;Lee Won Chan;Kim Pyoung Joong;Lee Pil Yong
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.2
    • /
    • pp.159-167
    • /
    • 1998
  • The environmental characteristics in shellfish farms were investigated in the western part of Jinhae Bay, 1996. During summer, anoxia and high nutrient concentrations were found in the bottom waters of shellfish farms. The concentrations of particulate organic species in seawaters were enriched, showing an average 57.44 uM for POC, an average 5.45 uM for PON, and an average 0.42uM for PP. The sediments environment in the farms was very polluted. The concentrations of COD and AVS were more than 20 mg/g.dry and 0.5 mg/g.dry, respectively. The total sedimentation rate was high as an average $7.81g/m^2/day$ with organic matter contents of $26\%$. Oxygen consumption rate was similar to polluted area as an average of $439mg/m^2/day$. Nutrient release rates were an average of $8.25mg/m^2/day$ for nitrogen and an average of $1.38mg/m^2/day$ for phosphorous. The cluster analysis through environmental data in summer indicated that DO, nutrient in the bottom water, and AVS in the sediment were important factors to characterize the polluted environmental site.

  • PDF

Citric Acid Production and Scale-up in Dual Hollow Fiber Bioreactor (이중실관 생물 반응기에서의 구연산 생산과 Scale-up)

  • 장호남;지동진;심상준
    • Membrane Journal
    • /
    • v.2 no.2
    • /
    • pp.122-128
    • /
    • 1992
  • A study on the citric acid production was performed in various size dual hollow fiber bioreactors with immobilized Aspergillus niger (KCTC 1232). The final dry cell mass density reached 300g/l based on the space volume available for cell growth. Under air and oxygen aeration the volumethe productivity reached 0.63 and 1.02g/l.h, which cormsponded to 10 and 16 fold over those of batch fermentation, respectively. The initial pH of the medium was a critical factor and the lower value resulted in higher citric acid yield. The increase in the feeding rate of medium or the number of reactor unit resulted in the improvement of the productivity due to higher consumption rate of substrate.

  • PDF

Changes in metabolic rate and hematological parameters of black rockfish (Sebastes schlegeli) in relation to temperature and hypoxia (수온과 저산소에 따른 조피볼락(Sebastes schlegeli)의 호흡대사와 혈액성상의 변화)

  • Kim, Heung-Yun
    • Journal of fish pathology
    • /
    • v.34 no.2
    • /
    • pp.213-224
    • /
    • 2021
  • Experiments were performed to investigate changes in metabolic rate (MO2), critical oxygen saturation (Scrit) and hematological parameters of black rockfish, Sebastes schlegeli exposed to hypoxia at 15, 20 and 25℃. The MO2 was measured at an interval of 10 min using intermittent-flow respirometry. The normoxic standard metabolic rate (SMR) was 116.5±5.5, 188.6±4.2 and 237.4±6.8 mg O2/kg/hr, and Scrit was 22.1±1.2, 30.6±1.5 and 41.9±1.4% air saturation at 15, 20 and 25℃, respectively. Q10 values were 2.62 between 15 and 20℃, 1.58 between 20 and 25℃, and 2.04 over the full temperature range. In the investigation of blood (hematocrit and hemoglobin) and biochemical parameters (plasma cortisol, glucose, electrolyte and osmolality), the rockfish were subjected to Scrit for each temperature during 4 hr. All of hematological parameters of the rockfish exposed to hypoxic water were significantly higher than those of normoxic control. Moreover, blood and biochemical parameters of the rockfish maintained to normoxic water showed the tendency of increase with temperature, and were significantly higher at 25C. As a result of this experiment, it was found that physiological stress due to hypoxia increased at high temperature.

Toxic Effects of Phenol on Survival and Oxygen Consumption of the Abalone Juvenile, Haliotis discus hannai (참전복, Haliotis discus hannai 치패의 생존과 산소소비에 미치는 phenol의 독성 영향)

  • KIM Heung-Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.496-504
    • /
    • 1997
  • This study was carried out to estimate toxic effects of phenol on survival and metabolism of the abalone juvenile, Haliotis discus hannai. The experiment was conducted by renewal bioassay procedure with different salinities at $20^{\circ}C$. The $LC_{50}$ of the juvenile exposed to phenol in the range of 0.5 and $100mg/\ell\;was\;34.3\~6.5mg/\ell\;at\;2.4\%_{\circ}\;and\;52.2\~9.3m/\ell\;at\;32\%_{\circ}$ salinity with exposure time from 24 hours to 96 hours. $LT_{50}$ was remarkablely reduced with increase of phenol conentration and decrease of salinity. Lethal toxicity or phenol was higher at low salinity than at high salinity. Therefore, salinity is likely to be one of factor to increase phenol toxicity. The oxygen consumption of the juvenile was reduced with increase of phenol concentration and with decrease of salinity. In spite of phenol toxicity, the oxygen consumption of the juvenile exposed to phenol of low concentration was high and similar as compared with that of control group. Survival rates of the abalone kept in phenol-free sea water after exposure to phenol concentration of 5, 10 and $20mg/\ell$ for 96 hours were reduced with decrease of salinity. Durations required to recover the normal metabolic rate of the juvenile, which was exposed to phenol concentration of 5, 10 and $20mg/\ell$ for 96 hours, were made longer with increasing phenol concentration. In the case of the juvenile exposed to sublethal concentration of phenol for 15 days, it were elongated as compared with that of the abalone exposed to phenol concentration caused acute toxicity. The result of this experiment indicated that relatively low concentration of phenol can impact on the abalone juvenile in marine ecosystem.

  • PDF

Effects of Oxygen Consumption in the Giant Grouper Epinephelus lanceolatus by Water Temperature and Photoperiod (수온 및 광조건에 따른 대왕바리 Epinephelus lanceolatus의 산소소비 특성)

  • Jeong, Minhwan;Kim, Sang-Duck;Lim, Han-Kyu;Kim, Moon-Jin;Kim, Bong-Seok
    • Korean Journal of Ichthyology
    • /
    • v.26 no.4
    • /
    • pp.259-266
    • /
    • 2014
  • This study investigated the effects of water temperature and photoperiod on oxygen consumption (OC) in the giant grouper Epinephelus lanceolatus. OC rate in the giant grouper at 17, 22, 27 and $32^{\circ}C$ were $61.7{\pm}0.4$, $72.2{\pm}0.6$, $102.9{\pm}0.8$ and $141.7{\pm}1.0mg\;O_2/kg/h$, respectively, indicating a linear increase in OC with water temperature. Photoperiod was regulated in accordance with the light (06:00~18:00 h, L) and dark (18:00~06:00 h, D) phases of the diel cycle (12L/12D), with a water temperature of at 17, 22, 27 and $32^{\circ}C$. OC rates during the light and dark phases were $62.7{\pm}0.4$, $62.5{\pm}0.3mg\;O_2/kg/h$, respectively, at $17^{\circ}C$. No significant differences were observed between the light and dark phases (P>0.05). OC raters during the light and dark phases were $74.8{\pm}0.7$, $69.6{\pm}0.6mg\;O_2/kg/h$ at $22^{\circ}C$, $107{\pm}1.2$, $98.0{\pm}0.7mg\;O_2/kg/h$ at $27^{\circ}C$ and $147.6{\pm}1.1$, $135.8{\pm}0.8mg\;O_2/kg/h$ at $32^{\circ}C$, respectively, indicating that OC is higher during daylight than nighttime. Giant grouper is thought to be a diurnal fish species, because the level of oxygen consumption during light period was higher than that during dark period.

Maximum Oxygen Consumption Determined by the Bruce and Inclined Treadmill Protocols

  • Kim, Kyu-Hwa;Kim, Hyeong-Jin;Kim, Kyoung-Soon
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.209-215
    • /
    • 1993
  • The aim of the present study was to derive regression equations for $\dot{V}o_{2max}\;vs.\;\dot{V}o_{2peak},\;and\;\dot{V}o_2\;vs.$ heart rate, exercise time, and other variables from maximal exercise tests on a treadmill using the Bruce and inclined protocols. Twelve male and 10 female Korean college students aged between 19 and 23 years voIunteered for this study. After the resting measurements, the subjects performed a maximal exercise on a treadmill according to the Bruce protocol. When the resting conditions were restored, the subjects performed another maximal exercise according to an inclined protocol where the speed was fixed at 8.05 $km{\cdot}h^{-1}$ and the grade was incremented starting from 09t by 2.5% for every 2 min. Peak $\dot{V}o_2$ observed during the Bruce exercise $(\dot{V}o_{2peak})$ was $37.7{\pm}2.4\;and\;31.7{\pm}1.8\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Peak $\dot{V}o_2$ observed during the inclined exercise was higher than $\dot{V}o_{2peak}$ during the Bruce exercise. Maximum $\dot{V}o_2$ value observed during the tyro exercises $(\dot{V}o_{2max})$ was $43.0{\pm}2.8\;and\;36.2{\pm}1.4\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Thus, $\dot{V}o_{2peak}$ by the Bruce protocol was about 12% (male) or 13% (female) lower than $\dot{V}o_{2max}$, and a linear relationship was found between $\dot{V}o_{2peak}$ and $\dot{V}o_{2max}$. The peak values of % $\dot{V}o_{max}$ with the Bruce protocol were $89.2{\pm}3.3\;and\;87.5{\pm}3.6%$ and those with the inclined protocol $97.7{\pm}1.8\;and\;96.9{\pm}2.0%$ in the male and female groups, respectively. In the female group, $%\dot{V}o_{2max}$ at a given workload was higher than in the male group, while $\dot{V}o_{2}$ per kg body weight was the same. Maximum HR observed during the two exercises was $204{\pm}2\;and\;195{\pm}3\;beat\;min^{-1}$ in the male and female groups, respectively. Linear relationships were found, excluding the last points, between 1) $\dot{V}o_{2}$ and exercise time, 2) $\dot{V}o_{2}$ and $%\dot{V}o_{2max}\;and\;%HR_{max}$.

  • PDF