New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

A Study on the Reclosing Overvoltage in 345 [kV] Transmission Line (345kV 계통 재투입과 전압 해석)

  • Yoon, Jae-Young;Park, Dong-Wook;Whang, Chi-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.166-169
    • /
    • 1990
  • The purpose of the circuit breaker on power system is to disconnect the faulty part from the system and to maintain the integrity of the system. With switching overvoltages are generated. When the system voltages become higher, switching overvoltage is important factor in insulation co-ordination. Since the no-load reclosing overvoltage with inductive source is severe, this paper deals with the reclosing overvoltage and the effect of closing resistor. This reclosing overvoltage of 27-bus model system with and without closing resistor is analyzed by using EMTP (Electro-Magnetic Transients Program) for both deterministic and Stochastic model.

  • PDF

The Conception & Fail-Mode Analysis of PTC Thermistor for Over-Current Protection (PST측면에서의 과전류 보호용PTC 소자의 개념 정립 및 Failure-Mode 분석)

  • 박준호
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.05a
    • /
    • pp.67-75
    • /
    • 2001
  • Circuitry to be connected to a Telecommunication Network consists of SELV CIRCUITS or TNV CIRCUITS. So International Standards, like as ITU-T Recommendation K.11, UL 1950, CSA C22.2 950 have been taken to reduce the risk that the Overvoltages from the power lines and from electrictraction lines, that may be received from the telecommunication network. Legal requirements may exist regarding permission to connect equipment having PTC components to a telecommunication network. Surge suppressors that bridge the insulation shall have a minimum d.c. sparkover voltage of 1.6 times the rated voltage or 1.6 times the upper voltage of the tared voltage range of the equipment. If left in place during electric strength testing of insulation, they shall not be damaged. In this work, The Conception & Fail-Mode Analysis of PTC components for Over-Current Protection is proposed. It guarantees the protection for PL Claim about this Subject.

  • PDF

A Study on the Consecutive Failure Due to Deterioration in Surge Arresters of the Offshore Wind Farm (해상 풍력발전단지에서 뇌격 시 서지어레스터 열화로 인한 연계 고장 분석)

  • Kim, Jin-Hyuk;Kim, Kyu-Ho;Lee, Jea-Kyun;Woo, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1265-1270
    • /
    • 2018
  • One of the ways to improve the stability of power facilities used in power systems is to use power surge arresters and to protect against transient overvoltages and surges in normal operation. Also it is important to reduce the impact of lightning strikes because lightning can create overvoltage in the grid of the wind turbine and affect power quality. So This paper analyzes the effects of overvoltage and adjacent turbines due to single strike and multi strike to ground impedance changes when the surge arrester is deteriorated in a wind power farm.

Analysis of Rate-of-rise of VFTO in GIS according to Measurement Point (측정 위치에 따른 GIS에서 VFTO 상승률 분석)

  • Oh, Yun-Sik;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.519-520
    • /
    • 2011
  • In Gas Insulated Substation(GIS), Very Fast Transient Overvoltages(VFTOs) are generated by the switching operation of disconnector or circuit breaker and it is propagated to each component of GIS. Each component of GIS is modeled by lumped line model and distributed line model based on equivalent circuits. The various cases which can be operated and the various closing point-on-wave are considered. In this paper, magnitude and rate-of-rise of VFTO are simulated and analyzed by comparing the simulation results. Measurements are performed at transformer and circuit breaker.

  • PDF

Switching Overvoltage Analysis of KEPCO 765KV System by EMTP (EMTP를 이용한 한전 765KV 계통 개폐과전압 해석)

  • Shim, Eung-Bo;Kim, Jeong-Boo;Jeon, Bok-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.945-948
    • /
    • 1992
  • In this paper, switching overvoltages are analyzed for future 765kv power system using EMTP(Electro Magnetic Transient Program) and compared with TNA (Transient Network Analyzer) study results which was previously undertaken during overseas training in 1980 and 1988. The result shows the maximum of 2.10 PU at midpoint of 310Km transmission line which is higher than those of TNA study by 0.4 PU. The deviation of EMTP result from TNA is caused by limitation of nonlinear representation and also frequency dependent modeling in EMTP. Further analysis are required to get more exact switching overvoltage factors for future KEPCO 765KV system not only by EMTP but also TNA.

  • PDF

A Study on Analysis of Surge Characteristics on Gas Insulated Transmission Lines (가스절연송전선로의 서지특성 분석에 관한 연구)

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won;Jang, Tai-In;Yoon, Jong-Keon;Kim, Yang-Sang;Suk, Kwang-Hyun;Kim, Hyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.371_372
    • /
    • 2009
  • This paper describes surge characteristics on 345kV combined transmission system mixed overhead line and GIL(Gas Insulated Transmission Line). Then, it is compared with the results of the system mixed overhead line and XLPE power cables. Finally the lightning overvoltages are also discussed according to surge arrester installation in two kinds of combined transmission systems when the lighting strikes on the phase conductor.

  • PDF

A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection (비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구)

  • Kim, Kyung-Chul;Kho, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

Changes of Electrical Characteristic of ZnO Varistors by a Lightning Impulse Current (뇌충격전류에 의한 산화아연형 바리스터의 전기적 특성변화)

  • 이종혁;손원진;김명진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.581-584
    • /
    • 2000
  • This paper describes the effect of lightning impulse current on ZnO varistors(390 V, 6.5 kA) used in low-voltage AC mains as a protective device against transient overvoltages. A lightning impulse current standardized in IEC 61000-4-5 is applied to the varistors, and the energy applied to the varistor at each time is about 12 J. In the experiment, various Parameters such as leakage current, reference voltage are measured with the number of applied impulse current. Also, micro-structure changes of the varistors after applying the lightning impulse current of 200 times are compared. The electrical characteristics of the varistors are degraded by overtime impulse current, showing increase in leakage current and decrease in reference voltage.

  • PDF

Fracture and Protection Technologies against Impulse of Power Arresters (전력용 피뢰기의 임펄스에 의한 파손과 대척 기술)

  • 한세원;조한구;김석수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.190-193
    • /
    • 2001
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, the fracture and protection technologies of arresters have to study according to their applications, namely ImA DC voltage, leakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. ZnO varistors which have nonlinear current-voltage characteristic name a number of failure mechanism when ZnO elements absorb surge energies. Failure mode by thermal stress and Pin hole are among the most common failure mechanism at the high current surge current. In this study, the fracture mechaism of power arresters are introduced and protection technologies are researched. In particular the effect of thermal stress by surge currents to ZnO elements and methods against arc surge energy through withstand structure design of arrester are discussed.

  • PDF