• Title/Summary/Keyword: Overload prevention

Search Result 55, Processing Time 0.025 seconds

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

Load Balance System for the SFC Based DLP solution (SFC 기반 DLP 솔루션을 위한 부하분산 시스템)

  • Song, Wang-Eun;Jung, Sou-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.4
    • /
    • pp.451-453
    • /
    • 2016
  • In this paper, we propose a Load Balance System for SFC based on DLP solution. SFC based on DLP solution does not distribute to the user data and each DLP server manages all traffic generated by the user device. When using existing algorithms such as the Load Balance Round Robin, Least Connection does not consider the resource usage of DLP server so traffic is not efficiently distributed due to different user traffic usage. It causes system failure and overload of the DLP server. Therefore, we propose the architecture of a Load Balance system for SFC based on DLP solution to perform the Load Balance based on the resource usage of DLP server through a LBM server in this paper.

A Study on the Thermal Analysis of Fire-Resistance Cable using FEM (유한요소법을 이용한 내화전선의 열해석에 관한 연구)

  • 오홍석;이상호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • In general, the insulation and protective sheaths on electrical conductors are made of combustible substances like PVC, natural or synthetic rubbers, and other organic or synthetic materials. When an electrical fire starts due to overheating of conductors/joints or sparking/arcing, the first thing to ignite is usually the insulation on the cables. When the insulation bums, the produced fumes are very toxic. To solve the problem, we have surely need the fire resistance cable that doesn't bum in a high temperature and emit toxic fume for operating a disaster prevention installation. In this paper, we have simulated the thermal analysis for the fire resistance cable according to the values of current in a overload and a short, and the values of outside flame with the fire resistance cable of the L's company product(600 V, FR-8 : Four Core) using the finite element method(Flux2D).

Adjustment of correlation coefficient for Pole transformer's load estimation and its reliability verification. (배전변압기의 전등부하 추정을 위한 상관계수 산정 및 신뢰성 검증)

  • Park, Chang-Ho;Han, Yong-Hee;KIm, Joon-Ho;Cho, Seong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1073-1075
    • /
    • 1999
  • This Paper Presents the process of load management for distribution Pole transformer at KEPCO. The purpose of this process is to establish reasonable peak load forecasting and prevention of Pole transformer damages caused by overload through the investigation of correlation coefficient for recent load characteristics. In this Paper, we newly proposed more reliable correlation coefficient using improved method and verified its reliability in various ways.

  • PDF

A Study on Hydraulic Control Characteristics of a Swashplate Type Axial Piston Pump-Regulator System by Linearization Analysis (사판식 액셜피스톤 펌프-레귤레이터계의 선형화해석에 의한 유압제어특성 고찰)

  • Jo, Seung-Ho;Kim, Won-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2535-2542
    • /
    • 2000
  • The regulator system has been modeled and combined to a swashplate type axial piston pump. Linear approximation has been performed for nonlinear coefficient terms of an axial piston pump-regulator model without significantly affecting accuracy. Based on the mathematical model of an axial piston pump-regulator system, a couple of characteristic curves of negative flow control and horsepower control are drawn, which show a good correlation with those of experimental results. So the simplified axial piston pump-regulator model in this paper is expected to be utilized not only for the design and analysis of hydraulic circuit of excavator but also for prevention of engine overload.

An Implementation of Full Virtualization based Intelligent Building System for Interface Overload Prevention (인터페이스 부하방지를 위한 전가상화 기반 지능형 빌딩 시스템 구현)

  • Kim, Oh Beom;Chung, Kwang Sik;Shon, Jin Gon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.1694-1697
    • /
    • 2010
  • 지능형 빌딩 시스템은 빌딩을 운영하는 다양한 단위시스템 정보를 통합하여 빌딩 거주자에게 쾌적하고, 안전한 생활을 할 수 있도록 운영하는 시스템을 말한다. 하드웨어적인 방법은 단위시스템에 비례하게 비용이 증가하는 단점이 있다. 소프트웨어적인 방법은 하나의 서버에서 정보를 수집하기 때문에 단위시스템에 통신량 증가로 인한 오류가 발생하면 전체 시스템에 영향을 미치는 단점을 가지고 있다. 본 논문에서는 소프트웨어적인 방법의 단점을 개선하기 위해서 부하 및 오류를 격리화할 수 있는 가상화를 이용하여 통합 관리 시스템과 인터페이스 관리 시스템으로 운영한다. 시스템의 구조는 통합 관리 모듈, 가상 관리 모듈, 구성 관리 모듈, 그리고 단위시스템 관리 모듈로 분리되며 제안 시스템을 사용함으로써 인터페이스 관리 시스템에서 발생하는 오류 및 부하로 인한 전체 시스템 오류를 축소시킬 수 있다.

Promotion or Prevention? The Moderating Effect of Embedded External Reviews on Consumer Evaluations

  • Ziqiong Zhang;Le Wang;Shuchen Qiao;Zili Zhang
    • Journal of Smart Tourism
    • /
    • v.3 no.3
    • /
    • pp.5-15
    • /
    • 2023
  • Given the increasing information overload among users of online review websites, understanding the manner in which cognitive costs are reduced and efficient information is made reliable has become increasingly important. This study targets a unique consumer review design and explores how reviews from an external peer-to-peer site embedded in an online travel agency (OTA) website influence subsequent evaluation behaviors. The empirical results indicate that (1) embedded external reviews with a high average valence tend to strengthen the influence of the positive evaluation ratio while diminishing the effect of the review volume, and (2) embedded external reviews with a large variance strengthen the positive effect of the review volume while weakening the effect of the positive evaluation ratio on subsequent positive evaluations. The findings provide practical insights for consumers and online platforms.

The Patterns of Accidental Injury in Young Children and Effect of Safety Education on Their Mothers Performance of Preventive Measures (영유아의 사고유형 실태조사와 안전교육 효과 분석)

  • Song In-Ja;Han Jung-Suk
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.55-74
    • /
    • 1998
  • In the past most major accidents resulted in death, but today there is a dramatic increase in the number of people who survive such accidents but who are left with permanent injury. Particularly, children who are inquisitive about their surroundings but immature in their ability to assess danger, are more vulnerable to accidents and their causes as well as to determine attitudes towards prevention. The main objective of the study was to assess the effectiveness of using an accident prevention manual for accident for accident prevention education. The study was a quasi-experimental study using a questionnaire format. The subjects of the study were 393 mothers of children attending six day care centers in Seoul. Data collection was done between May 1 and June 15, 1997. The tools used for the study were a questionnaire developed the researchers and a manual for accident prevention. The collected data were analyzed using SPSS. The results of the study are as follows: 1. Types of accidents included stabbing, bums, falls from heights, choking, falls on slippery surfaces, traffic accidents, drowning, poisoning, and electrical shock in that order of frequency. 2. The main causes of accidents in children were from cosmetics and household medications. 3. The most frequent locations of accidents in the home were the bathroom, kitchen, and stairways in that order. 4. For $90.4\%$ of children safety seats were not used when the ridding in a car. 5. In examining the parents' accident prevention practices, it was found that many parents used only . one electrical outlet for many appliances, tending to overload the electricity lines and that they were not practically concerned bout the flammability of children's pajamas, indicating a less than positive attitude towards fire prevention. 6. The parents had not provided their children with any instruction on accident prevention or on what to do after an accident had occurred. 7. After the use of pamphlet in an accident prevention education program, it was found that there was a statistically significant difference in the degree to which children carried out safety measures (t=14.96, p=.000) and in their safety habits (t=-1.67, p<.1) indicating an effectiveness in this method of education. The results of this study showed that there are many things in a child's environment that can cause accidents and that the possibility of an accident occurring is high. So nurses looking after children should be aware of the need for safety education to prevent accidents in the home and plan to provide appropriate educational material to help parents with this education.

  • PDF