• Title/Summary/Keyword: Overload faults

Search Result 23, Processing Time 0.027 seconds

Development of RCD Auxiliary Trip Device by using High Precision Current Sensor (고정밀 전류센서를 이용한 RCD 보조트립 장치 개발)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1532-1537
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution lines, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore this paper is confirmed the unreliability of the existing RCD by electrical faults simulation and is proposed a auxiliary trip device of RCD by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution lines caused by overload or electric short circuit faults. The sensitive reed switch in the proposed ATD (auxiliary trip device) exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and then rapidly cuts off the existing RCD. The proposed auxiliary trip device of RCD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed ATD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire (중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발)

  • Kwak, Dong-Kurl;Kim, Jin-Hwan;Lee, Bong-Seob
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

A Electrical Fire Disaster Prevention Device of High Speed and High Precision by using Semiconductor Switching Devices (반도체 스위칭 소자를 이용한 고속 고정밀의 전기화재 방재장치)

  • Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.423-430
    • /
    • 2009
  • Recently as the inactive response characteristics of the existing RCD used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper confirms the unreliability of the existing RCD by electrical fault simulator and proposes a EFDPD by using semiconductor switching devices and a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the self circuit breaker in EFDPD rapidly cuts off the system. The proposed EFDPD confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disasters, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults (아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults (접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul;Lee, Bong-Seob;Park, Young-Jic
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage (배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구)

  • Kwak, D.K.;Park, D.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF

Development on Electrical Fire Prevention System of Small Size and High Speed by using PTC Thermistor (PTC 서미스터를 이용한 소형 고속응성의 전기화재 방재시스템 개발)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.1
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is studied on a prevention system for electrical fire and electrical faults by using electrical temperature characteristic of PTC thermistor. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with $BaTiO_3$ ceramics of positive temperature coefficient. Also PTC shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point. This paper is proposed on a protective control system used with temperature sensor of PTC thermistor. The proposed prevention system will prevent electrical fires due to electric short circuit faults or overload faults. And the prevention system will solve the problems that circuit breakers to be commonly used at existing are happened frequently electrical fires and electrical disasters due to incapable operation, weak reliability and low speed response. Some experimental results of the proposed apparatus are confirmed to the validity of the analytical results.

  • PDF

A Study on Development of Electric Safety Control Apparatus by Using Thermal Characteristics of PTC Thermistor (PTC 서미스터의 온도특성을 이용한 전기안전 제어장치 개발에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.65-71
    • /
    • 2007
  • This paper is studied on a protective control system for electrical fire and electrical faults by using electrical and thermal characteristics of PTC thermistor. The PTC thermistor has characteristic or positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with $BaTiO_3$ Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point. This paper is proposed on a protective control system used PTC thermistor which is protected from electrical fire due to electric short circuit faults or overload faults. Some experimental results of the proposed electric safety control apparatus are confirmed to the validity of the analytical results.

A Study on Protective Control System for Electrical Fire using Characteristics of SCR and Multilayer-Type PTC Thermistor (SCR과 적층형 PTC 서미스터의 전기적 특성을 이용한 전기화재 보호제어시스템에 관한 연구)

  • Kwak Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.31-35
    • /
    • 2006
  • This paper is studied on a protective control system for electrical fire used electrical characteristics of SCR and multilayer-type PTC thermistor. The PTC thermistor has characteristic or positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with $BaTiO_{3_}$Ceramics of positive temperature coefficient. Also PTC shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point. This paper is proposed on a protective control system used multilayer-type PTC which is protected from electrical fire due to electric short circuit faults or overload faults. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

A Study on Electric Safety Control Device for Prevention of Over Current and Short Circuit Faults (과전류 및 단락사고 방지용 전기안전 제어장치에 관한 연구)

  • Jo, Si-Hwan;Kwak, Dong-Kurl;Jung, Do-Young;Shim, Jae-Sun;Kim, Jung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2100-2101
    • /
    • 2008
  • This paper is studied on a protective control system for electrical fire and electrical faults due to over current or electric short circuit faults by using electrical thermal characteristics of PTC (Positive Temperature Coefficient) thermistor and current response characteristics of high sensitive reed switch. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with BaTiO3_Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point, and reed switch, which is used for electrical fault current sensing devices, have a excellent characteristic of response velocity in degree of ${\mu}s{\sim}ms$ that sensing magnetic flux in proportion to dimension of line current. This paper is proposed on a protective control system use PTC thermistor and reed switch for sensor which is protected from electrical fire due to overload faults or electric short circuit faults. Some experimental results of the proposed electric safety control device are confirmed to the validity of the analytical results.

  • PDF