• Title/Summary/Keyword: Overload evaluation

Search Result 98, Processing Time 0.023 seconds

Study on Prediction of Net Thrust of Multi-Pod-Driven Ice-Breaking Vessel Under Bollard Pull and Overload Conditions According to the Change of Water Depth Using Computational Fluid Dynamics-Based Simulations (수심 변화에 따른 볼라드 당김 및 과부하 조건에서의 다중 포드 추진 쇄빙선박의 여유추력 추정에 대한 수치해석적 연구)

  • Kim, JinKyu;Kim, Hyoung-Tae;Kim, Hee-Taek;Lee, Hee-Dong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.3
    • /
    • pp.158-166
    • /
    • 2021
  • In this paper, a numerical analysis technique using a body force model is investigated to estimate the available net thrust of multi-pod-driven ice-breaking vessels under bollard pull and overload conditions. To employ the body force model in present flow simulations, drag and thrust components acting on the pod unit are calculated by using Propeller Open Water (POW) test data. The available net thrusts according to the direction of operation are evaluated in both bollard pull and overload conditions under deep water. The simulation results are compared with the model test data. The available net thrusts, calculated by the present analysis for ahead operating modes at 3~6 knots which are typical speeds of the target vessel in arctic field, are agreed well with the model test results. It is also found that the present result for astern operating mode appears approximately 6 % larger than the model test result. In addition, the available net thrusts are calculated under the both operating conditions accompanied by shallow water effects, and the main cause of the difference is studied. Based on the result of the present study, it is confirmed that the body force model can be applied to the performance evaluation of multi-pod propulsion system and the main engine selection in early design stage of the vessel.

Strengthening and Ductility Evaluation of Reinforced Concrete Beams Shear-Strengthened by Steel Plates and Glass Fiber Sheets (강판 및 유리섬유쉬트로 전단보강된 철근콘크리트 보의 보강 및 연성 평가)

  • 문상범;오성영;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.691-696
    • /
    • 2000
  • Shear strengthening method by steel plates and fiber reinforced polymer lamination has recently been favorably selected due to its efficiencies of duration and performance. Shear failure being brittle and difficult to predict, reinforced concrete structures must have sufficient capacity to absorb the energy for shear failure and to support temporarily the overload which may result due to the loss of shear capacity to the structure. These respects being considered, this research has carried out with the purpose of the experimental verification of the shear strengthening effect and ductility evaluation.

  • PDF

Right ventricular failure in congenital heart disease

  • Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.101-106
    • /
    • 2013
  • Despite developments in surgical techniques and other interventions, right ventricular (RV) failure remains an important clinical problem in several congenital heart diseases (CHD). RV function is one of the most important predictors of mortality and morbidity in patients with CHD. RV failure is a progressive disorder that begins with myocardial injury or stress, neurohormonal activation, cytokine activation, altered gene expression, and ventricular remodeling. Pressure-overload RV failure caused by RV outflow tract obstruction after total correction of tetralogy of Fallot, pulmonary stenosis, atrial switch operation for transposition of the great arteries, congenitally corrected transposition of the great arteries, and systemic RV failure after the Fontan operation. Volume-overload RV failure may be caused by atrial septal defect, pulmonary regurgitation, or tricuspid regurgitation. Although the measurement of RV function is difficult because of many reasons, the right ventricle can be evaluated using both imaging and functional modalities. In clinical practice, echocardiography is the primary mode for the evaluation of RV structure and function. Cardiac magnetic resonance imaging is increasingly used for evaluating RV structure and function. A comprehensive evaluation of RV function may lead to early and optimal management of RV failure in patients with CHD.

A Study on the Safty Diagnosis and Evaluation of Oil-immersed Transformer using fuzzy Algorithm (퍼지 알고리즘을 이용한 유중 변압기의 안전진단 및 평가에 관한 연구)

  • Kim, Young-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.190-195
    • /
    • 2006
  • In this paper, safety algorithm of transformer is introduced for the sake of MV/LV distribution customers by using fuzzy theory. The current-carrying capacity of transformer is usually determined by the maximum temperature at which the transformer is permitted to operate. Overload of transformer has an effect on transformer utilization rate and maximum temperature rises as well as maximum ambient temperature of insulating materials. Therefore, we proposed the safety algorithm considering the overload of transformer and ambient temperature in this paper. We introduced the correlational equations between each parameters using experimental data of IEEE std C57.91-1995, and deduced the result using fuzzy reasoning. We guessed the safety algorithm making a diagnosis for the safety status of oil-immersed transformer.

Promotion or Prevention? The Moderating Effect of Embedded External Reviews on Consumer Evaluations

  • Ziqiong Zhang;Le Wang;Shuchen Qiao;Zili Zhang
    • Journal of Smart Tourism
    • /
    • v.3 no.3
    • /
    • pp.5-15
    • /
    • 2023
  • Given the increasing information overload among users of online review websites, understanding the manner in which cognitive costs are reduced and efficient information is made reliable has become increasingly important. This study targets a unique consumer review design and explores how reviews from an external peer-to-peer site embedded in an online travel agency (OTA) website influence subsequent evaluation behaviors. The empirical results indicate that (1) embedded external reviews with a high average valence tend to strengthen the influence of the positive evaluation ratio while diminishing the effect of the review volume, and (2) embedded external reviews with a large variance strengthen the positive effect of the review volume while weakening the effect of the positive evaluation ratio on subsequent positive evaluations. The findings provide practical insights for consumers and online platforms.

Design and Evaluation of a VOD Buffer Management Algorithm Using Fixed Prefetch and Drop Strategics (고정 선반입과 Drop 정책을 이용한 VOD 버퍼 관리 알고리즘 설계 및 평가)

  • 박규석;문병철
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.2
    • /
    • pp.101-111
    • /
    • 2000
  • Resource managing is very difficult because the multimedia data compressed by a VBR shows a bit rate change within high range, Therefore, the VOD server should use the prefetch method in order to improve system utilization, such as prefetching data in the overload period by a meta table that is the reference pattern of MPEG data which is analyzed off line. This prefetch method will not result in a failure to display at overload, however, this method can not keep a minimum loading time and low costs, because the prefetched section is being maximizes. In this paper, we suggest another method that the system utilization can be improved using the fixed prefetched section to keep loading time and costs under a constant range at overload. But this technique will result in a failure to display, due to fixed prefetched section. Rut, in this paper we suggest a drop module that drops only the B frame in the GOP, consistently distributes a lower drop in media quality for the user.

  • PDF

Impact of Sink Node Location in Sensor Networks: Performance Evaluation (센서 네트워크에서 싱크 노드 위치가 성능에 미치는 영향 분석)

  • Choi, Dongmin;Kim, Seongyeol;Chung, Ilyong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.8
    • /
    • pp.977-987
    • /
    • 2014
  • Many of the recent performance evaluation of clustering schemes in wireless sensor networks considered one sink node operation and fixed sink node location without mentioning about any network application requirements. However, application environments have variable requirements about their networks. In addition, network performance is sufficiently influenced by different sink node location scenarios in multi-hop based network. We also know that sink location can influence to the sensor network performance evaluation because of changed multipath of sensor nodes and changed overload spots in multipath based wireless sensor network environment. Thus, the performance evaluation results are hard to trust because sensor network is easily changed their network connection through their routing algorithms. Therefore, we suggest that these schemes need to evaluate with different sink node location scenarios to show fair evaluation result. Under the results of that, network performance evaluation results are acknowledged by researchers. In this paper, we measured several clustering scheme's performance variations in accordance with various types of sink node location scenarios. As a result, in the case of the clustering scheme that did not consider various types of sink location scenarios, fair evaluation cannot be expected.

User-centered multimedia design: The application of discount usability engineering (사용자 중심의 멀티미디어 설계: 할인 사용성 공학의 적용)

  • 임치환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.41
    • /
    • pp.189-196
    • /
    • 1997
  • Multimedia systems present information by various media, for example, video, sound, music, animation, movie, etc., in addition to the text which has long been used for conveying the information. But using several media may cause users' confusion and poorly designed user interface often aggravate the situation. Hypermedia systems allow the retrieval and representation of multimedia information using navigation and browsing mechanisms. Typically, there are two major navigation problems in a hypermedia compared to the ordinary user interface: disorientation and cognitive overload. In this study, the multimedia system was studied from the viewpoint of usability. Practical usability evaluation needs cost-effective, low-skill, and low- investment methods. The 'discount usability engineering' method, one of these methods, is based on the use of the following techniques: scenarios, simplified thinking aloud, and heuristic evaluation. The discount usability engineering method was applied to the usability evaluation of multimedia CD-ROM title.

  • PDF

A Study on the Capacity Evaluation for Special Purpose ESS (특수용도용 교환기의 용량평가에 관한 연구)

  • 김동일;이재호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.7
    • /
    • pp.982-987
    • /
    • 1990
  • In this paper, the difference between call processing routing of general purpose ESS and that of special purpose ESS, such a TDX-ACD, was specified by analyzing the call processing capacity of special purpose ESS. Then the load sharing method was proposed in orde to reduce the overload condition in specific processors. Finally, measirement value was illustrated nad compared with simulation value.

  • PDF

A System IC for Controlling the Fire Prevention (화재방지제어 시스템 IC)

  • Kim, Byung-Cheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.737-746
    • /
    • 2009
  • In this study, we have developed one chip system IC for preventing the overload, detecting an abnormal conditions, and controlling the fire prevention in the intelligent home appliances. For the purpose, a circuit detectable an electric leak for preventing an electric shock, and a circuit detectable arc that has effect directly on the fire are designed. The circuits designed on every block are verified by comparing simulation with bread-boarding using a standard transistors. The system IC is fabricated by using 34 V 2 metal $1.5{\mu}m$ bipolar transistor process from evaluation results. The electrical performances of IC application circuits and the system IC equipped on PCB board are evaluated. It is confirmed that the system IC is well operated for arc and ground fault(GF) signal.