분기선로가 포함된 지중배전계통에서 서지특성 해석 및 보호방안에 관한 연구 (Analysis of Surge Behavior and Protection Method in the Underground Distribution Systems with Branch Lines)

  • 이장근;이종범;이재봉;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.148-150
    • /
    • 2006
  • This paper describes the overvoltage at the branch line in underground distribution systems when the direct lightning surge strikes on conductor of overhead line. Distribution systems are very complex because it includes many branch lines, transformers, switches and so on. Therefore model system consists of overhead distribution lines, underground cable include branch lines, lightning source and switches. Analysis are performed using EMTP to understand and evaluate the surge behavior on branch lines considering various conditions in underground distribution systems. Simulation results show overvoltage with location in various cases. It is evaluated that result will be used to establish protection methods in actual underground distribution systems.

  • PDF

해안지역 ACSR 가공지선의 기계적 특성 (Tensile Characteristics of ACSR Overhead Lines located in seaside)

  • 장태인;강지원;이동일;장인출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1709-1711
    • /
    • 2001
  • The remaining life of ACSR(Aluminum Conductor Steel Reinforced) wires exposed to the atmosphere for a long period relies on the extent of deterioration caused by environmental factors such as atmospheric corrosion, galvanic corrosion, crevice corrosion and fatigue corrosion. We investigated the tensile characteristics of ACSR wires in a coastal area through several mechanical tests, and analyzed the constituents of them using SEM(scanning electron microscope). Test samples are parts of ACSR 97[$mm^2$] overhead transmission lines in that area. The result shows that ACSR wires exposed to salt may lead to rapid mechanical deterioration.

  • PDF

고강도 강선의 인장 및 회전굽힘 피로특성 (Characteristic of fatigue properties with tension and bending loading using high strength steel wire)

  • 우병철;김상수;김병걸;서창민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.274-279
    • /
    • 2000
  • The overhead transmission wires operating both at warm temperature and tighten state for a long period of time in a power transmission plant are degraded by air pollution, wind, creep and slip between steel wire and aluminium conductor. The objective of this study is to investigate a high carbon steel wire. We tested for basic mechanical properties and 3 types fatigue behavior, tension-tension, 4 points bending and 3 points bending fatigues. In this study, a conventional fatigue strengths between 4 points bending and tension-tension fatigue were determined by Gerber, Sorderberg and Goodman's theory and we investigated S-N diagram for bending and tensile loading.

  • PDF

전차선로 절연물의 안전성 평가기준 검토 (A review of Safety standards for insulating materials in overhead contact line)

  • 이재봉;정호성;이기원;권삼영;이기승;조호령
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.269-274
    • /
    • 2008
  • The Seoul subway is acting the center of public transportation after the opening of the first line on August 15, 1974. and the subway line of the DC traction system is running and building to the ninth line. However, the main insulation parts used in overhead contact line are now imported from overseas products. Therefore, this paper considers domestic manufacture technology, supply easiness and economic effectiveness of insulation products and reviews the safety of support insulator used in rigid conductor line, stem insulator used in movable bracket and AC/DC different phase section insulator that localization development is necessary.

  • PDF

EFFECT OF Al/Cu WEIGHT FRACTION ON THE MECHANICAL AND ELECTRICAL PROPERTIES OF Al-Cu CONDUCTORS FOR OVERHEAD TRANSMISSION LINES

  • DEOKHYUN HAN;GEON-HONG KIM;JAESUNG KIM;BYUNGMIN AHN
    • Archives of Metallurgy and Materials
    • /
    • 제65권3호
    • /
    • pp.1019-1022
    • /
    • 2020
  • In the past few years, overhead copper transmission lines have been replaced by lightweight aluminum transmission lines to minimize the cost and prevent the sagging of heavier copper transmission lines. High strength aluminum alloys are used as the core of the overhead transmission lines because of the low strength of the conductor line. However, alloying copper with aluminum causes a reduction in electrical conductivity due to the solid solution of each component. Therefore, in this study, the authors attempt to study the effect of various Al/Cu ratios (9:1, 7:3, 5:5) to obtain a high strength Al-Cu alloy without a significant loss in its conductivity through powder metallurgy. Low-temperature extrusion of Al/Cu powder was done at 350℃ to minimize the alloying reactions. The as-extruded microstructure was analyzed and various phases (Cu9Al4, CuAl2) were determined. The tensile strength and electrical conductivity of different mixing ratios of Al and Cu powders were studied. The results suggest that the tensile strength of samples is improved considerably while the conductivity falls slightly but lies within the limits of applications.

현수I련을 부가한 점퍼장치의 횡진억제효과 분석 (The Swing Restraint effects for Suspension I string type Jumper Devices)

  • 손홍관;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.35-37
    • /
    • 1997
  • The jumper devices of overhead transmission lines are getting increased in size with the adaptation of higher voltage and bundled conductor. Incensement of jumper devices size caused to large swing angle and flashover with tower post or arm. The suspension I type string type jumper devices are used for swing restraint of suspension type. This paper is compared and analysized to its swing characteristics. The results showed that suspension I string type has a good effects.

  • PDF

송전선로에서 Spacer-Damper 설치시공의 중요성 (Importance of the Spacer-Damper Installation in Overhead Lines)

  • 이형권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.46-48
    • /
    • 2005
  • Wind-induced oscillations are known to cause damage to the conductors and related hardware through fatigue, clashing of the bundled conductors and bolt loosening. Wake-induced oscillations have been known since the advent of bundled conductors. they are caused by aerodynamically unstable forces acting on the leeward conductors in the wake of the windward conductors, In order to control it, spacer dampers are installed in transmission lines with bundled conductors. Spacer damper installation is very important, it can cause damage to the conductors and spaer damper itself. This paper suggests importance of spacer damper installation in bundled conductor systems.

  • PDF

실증시험선로를 이용한 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 이온류 특성 평가 (Ion Effects of HVDC ±500 kV Double Bipole Overhead Transmission Line with Metallic Return Conductor Using Full-scale Test Line)

  • 신구용;권구민;주문노;우정민
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.249-256
    • /
    • 2019
  • 국내에 향후 건설 예정인 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 최적선로 형상을 설계하고 송전선로에서 발생되는 전기환경장해를 검증하기 위해 실증시험장을 구축하여 1년간 전기환경장해 평가시험을 수행하였다. 또한, HVDC Double Bipole 실선로에서 인체의 지표면 전계인지도 평가시험을 통해 HVDC 실규모 실증선로 직하에서 인체가 직류 전계를 감지하는 임계값을 조사하여 HVDC ±500 kV Double Bipole 가공송전선로의 직류전계 설계기준안의 타당성을 검증하였다. HVDC ±500 kV Double Bipole 시험선로의 극형상은 전기환경장해와 운영관점에서 동일한 극성을 대각으로 배치하였으며, 국내 가공송전선로의 전기환경장해의 사회적인 수용성을 고려하여 선로에서 코로나방전이 거의 발생되지 않도록 소도체 방식은 6 도체를 선정하였다. 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로 방식인 Cardinal×6B를 적용한 실증시험결과, 선로 도체에서 코로나 방전이 거의 발생되지 않았으며, 따라서 지표면 전계와 이온전류밀도는 모두 국내 가공송전선로 설계 기준값을 만족하였다. 또한 선로직하에서 피조사자들에 대한 전계 인지도 평가결과, 피조사자들의 70%는 23 kV/m에 노출되어도 직류전계를 인지하지 못하는 결과를 나타냈다.

2회선 가공송전선의 단시간정격에 관한 평가방법 (An Evaluation Method for Short-Term Ratings of Double-Circuit Overhead Transmission Lines)

  • 김성덕;손홍관;장태인
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.20-28
    • /
    • 2007
  • 본 논문에서는 2회선 가공송전선에 대하여 2회선 중 1회선에 고장이 발생한 경우에 안전하게 운전할 수 있는 단시간정격을 결정하기 위한 해석적 방법을 기술한다. 도체의 온도특성을 나타내는 열평형방정식을 선형화 함으로써 이 선형방정식으로 1회선 선로에 과부하가 발생하는 동안 과전류와 그 온도 특성을 쉽게 표현할 수 있다. 일반적으로 단시간 선로정격은 도체의 수명과 이도를 동시에 고려하여 결정해야 한다는 것은 잘 알려진 사실이다. 그렇지만 대부분의 전력회사는 단시간정격에 대한 각자의 다른 지침을 갖고 있다. 이 논문에서는 제안된 방법을 사용하면 과거 3시기에 건설된 한국전력공사의 가공송전선에 규정된 단시간정격을 재평가할 수 있고, 그 결과 단시간정격을 효율적으로 증대시킬 수 있음을 확인하였다. 또한 이 방법은 2회선 선로 중 1회선에 고장이 발생할 경우에 기존 선로에 어떤 조치도 하지 않아도 단시간 동적송전용량을 결정하는데 직접 이용할 수 있을 것이다.

풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석 (Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests)

  • 이두영;구재량;박수만;김동환
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.79-88
    • /
    • 2017
  • 본 논문은 송전선로 갤러핑 현상 분석을 위해 요구되는 비대칭 송전선의 공기력 계수 측정에 관한 것으로, 세 종류의 비대칭 단면으로 구성된 단도체, 2도체 및 4도체 모형에 대해서 난류 조건에서의 풍동실험을 수행하였다. 송전선로 갤러핑은 비대칭의 착빙된 송전선에 안정된 바람이 작용하는 경우 발생하는 유체유발진동의 한 종류로, 상간 이격거리와 송전탑 하중의 계산 등 송전선의 설계시 고려해야하는 주요 인자 중 하나이다. 갤러핑에 의해 발생하는 반복적인 변동 하중은 송전선을 포함한 체결 부품 등에 큰 동응력을 발생시키는 것을 고려하여, 송전선을 비롯한 각종 부품은 마모와 피로손상에 견딜 수 있는 충분한 내구성을 가져야 한다. 국내에서도 빙설해에 의한 송전선로의 고장은 급격한 전압 강하로 인한 전기 품질에 큰 영향을 끼치는 주요 원인이 되고 있으며, 매년 약 20건 이상씩 발생하고 있는 점을 고려해, 안정적인 전력 공급과 유지, 보수 비용을 절감하기 위해서 갤러핑 현상에 대해서 기초부터 체계적인 접근이 요구되고 있다.