전기철도 강체전차선로의 정적 상태 검출 기술 연구 (A Study on Technologies for Measuring Static Condition of Rigid Conductor System in Railway Electrification)

  • 나경민;이기원;박영
    • 한국전기전자재료학회논문지
    • /
    • 제32권6호
    • /
    • pp.507-511
    • /
    • 2019
  • The purpose of an electric railway system contact wire is to supply electric energy to trains through a contacted pantograph. This energy is then converted into mechanical energy. Recent developments in overhead contact lines include the increase in the tension force up to 34 kN according to train speeds that reach up to 400 km/h with a verified safety. Rigid conductor catenary (R-Bar) for high speeds of up to 250 km/h have been developed in tunnels to save on construction costs. This is significant because minor defects in R-bars in aspects, such as height and stagger affect installation conditions. In this study, we propose the use of a detector that measures the static characteristics to reduce the R-bar installation errors. This detector has been developed to measure the height and stagger of the contact wire using video images.

HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발 (Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line)

  • 길경석;양광호;이성두;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

Study on Thermal Load Capacity of Transmission Line Based on IEEE Standard

  • Song, Fan;Wang, Yanling;Zhao, Lei;Qin, Kun;Liang, Likai;Yin, Zhijun;Tao, Weihua
    • Journal of Information Processing Systems
    • /
    • 제15권3호
    • /
    • pp.464-477
    • /
    • 2019
  • With the sustained and rapid development of new energy sources, the demand for electric energy is increasing day by day. However, China's energy distribution is not balanced, and the construction of transmission lines is in a serious lag behind the improvement of generating capacity. So there is an urgent need to increase the utilization of transmission capacity. The transmission capacity is mainly limited by the maximum allowable operating temperature of conductor. At present, the evaluation of transmission capacity mostly adopts the static thermal rating (STR) method under severe environment. Dynamic thermal rating (DTR) technique can improve the utilization of transmission capacity to a certain extent. In this paper, the meteorological parameters affecting the conductor temperature are analyzed with the IEEE standard thermal equivalent equation of overhead transmission lines, and the real load capacity of 220 kV transmission line is calculated with 7-year actual meteorological data in Weihai. Finally, the thermal load capacity of DTR relative to STR under given confidence is analyzed. By identifying the key parameters that affect the thermal rating and analyzing the relevant environmental parameters that affect the conductor temperature, this paper provides a theoretical basis for the wind power grid integration and grid intelligence. The results show that the thermal load potential of transmission lines can be effectively excavated by DTR, which provides a theoretical basis for improving the absorptive capacity of power grid.

154 kV 복도체 가공송전선로에서 전자력에 의한 소도체간 접촉 (Kissing of Sub-conductors due to Magnetic Forces in a 154 kV Bundled Overhead Transmission Line)

  • 김상범;노희원;김영홍;고광만;박종혁;김상수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.383-389
    • /
    • 2016
  • 국내 154 kV 복도체 가공송전선로를 대상으로 전자력에 의한 소도체간 접촉현상을 실증적으로 재현하고 대처 방안을 제시하였다. 도체에 흐르는 전류의 크기가 클수록, 스페이서의 간격이 클수록 소도체간에 작용하는 전자력은 크게 측정되었다. 스페이서 간격이 68 m일 경우 전류 크기가 2,000 A 일 때부터 소도체는 불안정한 상태가 되어 소도체간 간격이 변화하는 횡방향 진동이 시작되었다. 스페이서 간격이 136 m일 경우 전류 크기가 증가할수록 소도체간 간격은 좁아지다가 2,250 A 일 때 두 소도체는 완전히 접촉하였다. 스페이서 간격에 따른 전자력의 크기를 도식화하고 안전한 스페이서 간격을 제시하였다. 시험선로와 실선로 간에는 접촉현상이 발생하는 조건이 상이한 것으로 나타났으며, 이는 송전선로 가선 과정에서 도체에 가해진 여러 형태의 잔류 응력, 바람 조건 등의 차이 때문으로 판단되었다.

고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화진단시스템 개발 (Development of Deterioration Diagnosis System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines)

  • 김성덕;이승호
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.43-50
    • /
    • 2000
  • 본 논문에서는 국내의 고압 가공배전선으로 일반적으로 사용되는 ACSR-OC의 열회를 검출하기 위하여, 솔레 노아드 와류센서를 가진 비파괴 검사시스템의 설계와 실험을 다루었다. ACSR-OC 도체에 대한 부식기구와 열회 상태를 검토하므로써, 부식이 도채의 유효단면적을 감소시키는 것을 확인하였다. 노화도체의 극심한 부적정도룹 검출하고 정량화하기 위한 실용적인 전기.자기적인 방법올 제시하였다. 고주파 정전류원, 신호처리 부와 모터 구동/제어기로 구생되눈 계측시스템이 설계되고 시험되었다. 이 장치는 센서의 출력을 검출하고 검사도체의 직경변화를 연속적으로 추정하는 기능을 갖고 있다. 그 결과, 와류센서를 가진 부각검출시스템은 가공 재전선의 열화에 기인한 심각한 결함을 추정하고 극심한 노호도체가 단선되기 전에 사전 경고를 하는데 양호한 효용성을 나타내는 것을 확인하였다.

  • PDF

가공송전선로의 비상용량 응용과 평가 (Application and Evaluation of Emergency Rates in Overhead Transmission Lines)

  • 김성덕
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.442-446
    • /
    • 2014
  • 본 논문에서는 ACSR 가공송전선로의 전력공급 신뢰도를 증진시키기 위한 비상정격의 적용방안에 대하여 기술하였다. 전력산업의 재편으로 인하여 한국전력은 물론 세계의 대부분 전력회사들은 새로운 투자를 하지 않으면서 경제적인 전략들만 모색하여 왔다. 그러나 전력수요가 급격히 증가하였으나 발전량의 증가는 충분히 따라가지 못했다. 따라서 첨두부하 시나 송전선로의 고장의 경우에 기존 송전선로의 송전용량을 증가시키기 위하여, 단시간 또는 장시간정격과 같은 비상용량을 적용하는 방법을 제안한다. 만약 첨두부하시, 정적송전용량 대신에 장시간 비상용량을 적용하면 10 % 또는 그 이상의 전력증대가 가능하다. 또한 2회선 송전선로 중 1회선 고장이나 과부하 경우에 비상용량이 효과적으로 사용될 수 있음을 확인하였다.

산불에 노출된 가공송전선의 열화특성연구

  • 장용호;김병걸;김상수;한세원;이원교
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.282-282
    • /
    • 2009
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very important to maintain transmission line safely. Specimenes for this study were Al conductores of ACSR $410mm^2$, ACSR 480 R and ACSR $240mm^2$. This paper describes the changes of mechanical and electrical properties of same flame exposed Al conductor. The detailed will be given in the text.

  • PDF

지중송전케이블 뇌서지 유도현상 분석 (Analysis of Induced Lightning Surge Phenomena on Underground Power Cables)

  • 정채균;강연욱;강지원;김두진;김재승;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.578-579
    • /
    • 2011
  • This paper describes the analysis of induced lightning surge phenomena at underground power cables under construction when the lightning surge strikes at phase conductor of grounding wire of overhead line in service. Therefore, This paper proposes the optimal protection methods establishment against lightning surge induced from operating transmission.

  • PDF

가공배전선로의 기준이도 적용시 상정최대장력에 관한 연구 (A Study on Maximum Tensile Strengths of Overhead Distribution Conductor Tensioned by Standard Sag of KEPCO in)

  • 왕윤찬;선상진;김창완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.307_308
    • /
    • 2009
  • 본 연구에서는 아연도강연선을 인류주에 보통지선으로 시설할 때 전선의 불평균장력을 지지할 수 있는 최대허용불평균장력을 계산 후 현재의 가공배전선 중 가장 많이 사용하는 ACSR/AW-TR/OC 전 규격에 대하여 기준이도로 시설시 최악조건의 상정최대장력과 비교함으로써 기준이도의 재설정 필요성 여부를 검토하고자 하였다. 연구 결과 ACSR/AW- TR/OC $160mm^2$$240mm^2$은 장경간 개소의 고온계 강화 지역 상정최대장력보다 단경간 개소의 저온계 상정최대장력이 큼을 발견하였고, 지선을 아연도강연선 7/3.5mm이하로 시설 가능하도록 ACSR/AW- TR/OC $160mm^2$$240mm^2$의 기존이도를 재설정하는 연구를 진행할 필요성이 있음을 확인하였다.