• 제목/요약/키워드: Overall type

검색결과 3,319건 처리시간 0.035초

베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube)

  • 전철호;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

신규 저소음 및 고효율 머플러 적용 회전식 압축기 개발 (Development of a Low Noise and High Efficiency Rotary Compressor with a New Muffler)

  • 장인선;김봉준;윤영;성춘모;이승갑
    • 한국유체기계학회 논문집
    • /
    • 제8권2호
    • /
    • pp.23-30
    • /
    • 2005
  • The rotary compressor is widely used in the air conditioner because it is efficient and compact. Recently, the need for silent and efficient compressors is much stronger than the past. The new type muffler was invented to reduce the noise level and to improve the efficiency. The new type muffler that has two side discharge holes and dome shape resulted in much lower overall noise level, especially noise levels around 1kHz than the old type one of one center discharge hole in the acoustic spectra. Also it showed a higher efficiency of air conditioner by lowering oil discharging amount of a compressor than old type one of a rectangular shape and two side discharge holes. The noise reduction and efficiency improvement by the new type muffler were verified by tests for votary compressors and air conditioners.

자동차 워터펌프 밸런스 홀 직경이 수력성능 및 축추력에 미치는 영향 (Effects of the Balance Hole Diameter of an Automotive Closed Type Water Pump on Hydraulic Performance and Axial Force)

  • 이기수;허형석;김현철;오창복
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.111-117
    • /
    • 2008
  • The aim of this paper was to investigate the fluid dynamic behavior of the automotive closed type water pump with balance hole in order to evaluate and justify its overall hydraulic performance and, in particular to analyze the effects of the balance hole on the reduction of hydraulic flow force of it. The analysis has been peformed by applying the commercial computational fluid dynamics (CFD) code, Fluent, to the solution of the 3-D turbulent flow fields of automotive closed type water pump. The reliability of the employed analysis was demonstrated by the comparison between numerical result and experimental data. Although, hydraulic head of the closed type water pump with 3mm diameter of balance hole decreased by 1.1%, axial flow force was effectively reduced by 13.3%, comparison of it with no hole at design point.

2 kW급 MCFC용 평편형 개질기 운전결과 (The Performance & Operation Analysis of a Plate Type Reformet for 2 kW Class MCFC Stack)

  • 서혜경;안교상;임희천;이상득
    • 한국수소및신에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.159-167
    • /
    • 2002
  • The operation results of the 2kW class plate type reformer, which has several advantages compared with the tubular burner type reformer, are analyzed. This plate type reformer is composed of six combustion chambers and five reforming chambers by turns. The methane conversion rate at 1.6 absolute pressure is about 84%, which is reasonably similar to theoretical value, 85.3%. Though the abrupt interruption was made just by the carbon deposition during heating the fuel line to combustion chambers around 200 hours operation, the overall steady state operation is more than 450 hours. These operation results show the verification of long run performance and the possibility of direct connection between plate reformer and fuel cell stack.

초등학생의 부모·교사·또래 애착 유형별 자아개념 및 학교생활적응 (Elementary School Children's Self-Concept and School Life Adjustment according to Attachment Types of Parents, Teachers and Peers)

  • 김분;최연실
    • 대한가정학회지
    • /
    • 제50권1호
    • /
    • pp.1-13
    • /
    • 2012
  • The purpose of this research is to explore the self-concept and school life adjustment based on group classification of attachment types with parents, teachers and peer groups among 6th grade students at elementary schools. The findings suggest that attachment is highest with one's mothers, followed by peer groups, fathers and teachers. This is in accordance with the overall tendencies of children to be attached to their parents, teachers, peer groups, according to their self-concept and school life adjustment. In addition, the tendency of attachment with parents, teachers, and peer groups according to gender is not meaningful except for peer-group affection between boys and girls. Furthermore, an integrated attachment type is ranked highest, followed by parents attachment type, peer attachment type, and unstable attachment type, in order based on cluster analysis. Finally, each attachment group among students showed meaningful differences in socio-demographic variables, self-concept, and school life adjustment.

확대모델을 이용한 특성화된 핀형상의 열전달평가 (An Evaluation of Heat Transfer Characteristics of Individualized Fin Type Using Large Scale Model)

  • 윤점열;강희찬;이관수;김무환
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.166-175
    • /
    • 1996
  • In recent years, air-conditioning units designed with higher efficiency and more compactness are required due to emphasis on energy efficiency in home electrical appliances. This trend in the air-conditioning industries has accelerated the development of improved heat exchanger with a better performance in heat transfer aspects. In this study, experiments were performed to investigate the shape and configuration of fins affecting on the performance of the conventional fin-and-tube type heat exchanger equipped in a commercial air conditioners. The geometry similtude method was employed to measure the heat transfer coefficient and pressure drop. Experimental results show that this method is very useful to analyze the heat transfer characteristics of the fin-and-tube type heat exchanger. It is also found that the slit fin has better performance than the conventional fin type in the air conditioners. The present results indicate that heat transfer from the fin si influenced by the parameters such as the forming area of the slit fin, the type of interrupted surfaces like a louver or slit, slit patterns and slit raised direction, and it also affects the overall heat exchanger performance.

  • PDF

밴드형 발열조끼의 디자인 개발 (Development of Design for Band Type Heating Vests)

  • 이병홍;이주은
    • 패션비즈니스
    • /
    • 제19권5호
    • /
    • pp.93-109
    • /
    • 2015
  • By the influence of ageing population, the well-being trend, and the increase of interest in health, people seems to be enjoying sports and outdoor life more. Followed by the change of consumers' life style, the interest in smart clothing grafting scientific technology has increased, and research on this subject is necessary. This study is to develop improved design of band type heating vests by grasping the weak point of currently sold heating vest designed by the manufacturer. Through this process, satisfaction of the consumer and the manufacturer can be increased. The results of this study are as follows: 1) Conducted a demand survey with the manufacturer and wearing evaluation test with the consumer on band type heating vests. 2) Suggested design drafts on band type heating vests for both genders reflecting demand survey results. 3) Conducted consumers' preference survey for design drafts. 4) Made the sample product, and then conducted an evaluation of wearing the actual product. Overall, the wearing test results showed high satisfaction for both genders.

EVOLUTION OF THE SPIN OF LATE-TYPE GALAXIES CAUSED BY GALAXY-GALAXY INTERACTIONS

  • Hwang, Jeong-Sun;Park, Changbom;Nam, Soo-hyeon;Chung, Haeun
    • 천문학회지
    • /
    • 제54권2호
    • /
    • pp.71-88
    • /
    • 2021
  • We use N-body/hydrodynamic simulations to study the evolution of the spin of a Milky Way-like galaxy through interactions. We perform a controlled experiment of co-planar galaxy-galaxy encounters and study the evolution of disk spins of interacting galaxies. Specifically, we consider cases where the late-type target galaxy encounters an equally massive companion galaxy, which has either a late or an early-type morphology, with a closest approach distance of about 50 kpc, in prograde or retrograde sense. By examining the time change of the circular velocity of the disk material of the target galaxy from each case, we find that the target galaxy tends to lose the spin through prograde collisions but hardly through retrograde collisions, regardless of the companion galaxy type. The decrease of the spin results mainly from the deflection of the orbit of the disk material by tidal disruption. Although there is some disk material which gains the circular velocity through hydrodynamic as well as gravitational interactions or by transferring material from the companion galaxy, it turns out that the amount of the material is generally insufficient to increase the overall galactic spin under the conditions we set. We find that the spin angular momentum of the target galaxy disk decreases by 15-20% after a prograde collision. We conclude that the accumulated effects of galaxy-galaxy interactions will play an important role in determining the total angular momentum of late-type galaxies.

Experimental Study on Heat Transfer Performance of Absorber with Variable Plate Types

  • M.A. Sarker;Moon, C.G.;Lee, H.S.;Kim, E.P.;Yoon, J.I.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 춘계 학술발표회 논문집
    • /
    • pp.201-212
    • /
    • 2004
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of developing high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is important to improve the performance of absorber with the larger heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which could increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, that is, horizontal tube bundle type. The size of plate absorbers were made for 0.4m$\times$0.6m and the design objective of a refrigeration capacity was 1RT. In this experiment, three kinds of plate absorbers namely flat plate, dimple plate and groove plate were used. The obtained results were less than the design objective values, that is, the refrigeration capacity was about 0.3 ~0.4RT and the overall heat transfer coefficient was 500~600 kcal/$m^2$h$^{\circ}C$ at the standard conditions.

  • PDF

국내 종합병원의 형태 유형 변화에 관한 연구 (A Study on the Change of Form Type in General Hospital)

  • 김은석;양내원
    • 한국실내디자인학회논문집
    • /
    • 제23권6호
    • /
    • pp.195-203
    • /
    • 2014
  • This study selects factors affecting form type of hospital architecture by considering studies and references on hospital architecture type in korea and other countries in general. Also this study classifies general hospitals chronologically and analyzes type change of general hospitals in relation with periodic change of healthcare environment. Through this, this study aims to analyze chronological change of general hospitals' form type and provide the current of hospital architecture's general type. The form type classification of this study is classification according to the form of ward, classification according to the relationship between ward and D.T.D(Diagnostic and Treatment department), classification according to the relationship between O.P.D(Out Patient department) and D.T.D, classification according to the rate of centralization, classification according to the circulation system. The form type of ward changed from plate type to tower type, and the circulation system of ward changed from middle corridor to double corridor, the number of Team Nursing chaged from 1 to 2 in 1990. On the other hand the chage of others classifications took place from 1990' to 2010'. It is judged that this overall change is appeared by a change from an inpatien-oriented system to an outpatient-oriented system followed by an increase in number of outpatients, an increase in amenities in ground floor and adoption of healing environment for patients and visitors.