• 제목/요약/키워드: Overall measurement system

검색결과 379건 처리시간 0.027초

산세라인 자동화를 위한 농도 측정 시스템 개발 (Development of a Concentration Measurement System for Pickling Line Control)

  • 박형국;이종현;노일환
    • 제어로봇시스템학회논문지
    • /
    • 제19권10호
    • /
    • pp.891-895
    • /
    • 2013
  • This paper proposes the development of a new method for online analysis which measured acid concentration in a pickling line. Pickling is the most important step to remove surface scale layers and is strongly depending on the exactly controlled pickling liquor composition. Today, there is no feasible system available for the online control of pickling lines. Within this paper, new methods for online analysis of pickling liquors have been tested and implemented into an overall pickling process control tool. This method measured simultaneously the hydrochloric acid and iron ion concentration in a solution of hydrochloric acid by measuring the ultrasonic speed, the solution temperature, and the electrical conductivity. Experimental results showed excellent precision and the measurement error was ${\pm}2g/l$ compared with the neutralization titration measurement.

엔진 냉각 시스템 개선에 관한 연구 (A Study on Improvement of Engine Cooling System)

  • 김문헌;오병욱
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.103-116
    • /
    • 1994
  • In this study the behavior of engine cooling loss and overall heat transfer coefficient were studied experimentally using naturally aspirated engine and turbo charged engine. Using turbo charging, heat dissipation was increased because of the density of the mixture was increased with increment of inlet air flow rate. Therefore, cooling loss of turbo charged engine is larger than naturally aspirated engine. As taking the measurement of surface temperature of combustion chamber, gas heat transfer coefficient was calculated and found that it has greatly affected to overall heat transfer coefficient. The empirical formula of overall heat transfer coefficient established in order to predict of engine cooling loss and express only as a function of mean piston velocity.

  • PDF

An Integrated Approach to Measuring Supply Chain Performance

  • Theeranuphattana, Adisak;Tang, John C.S.;Khang, Do Ba
    • Industrial Engineering and Management Systems
    • /
    • 제11권1호
    • /
    • pp.54-69
    • /
    • 2012
  • Chan and Qi (SCM 8/3 (2003) 209) developed an innovative measurement method that aggregates performance measures in a supply chain into an overall performance index. The method is useful and makes a significant contribution to supply chain management. Nevertheless, it can be cumbersome in computation due to its highly complex algorithmic fuzzy model. In aggregating the performance information, weights used by Chan and Qi-which aim to address the imprecision of human judgments-are incompatible with weights in additive models. Furthermore, the default assumption of linearity of its scoring procedure could lead to an inaccurate assessment of the overall performance. This paper addresses these limitations by developing an alternative measurement that takes care of the above. This research integrates three different approaches to multiple criteria decision analysis (MCDA)-the multiattribute value theory (MAVT), the swing weighting method and the eigenvector procedure-to develop a comprehensive assessment of supply chain performance. One case study is presented to demonstrate the measurement of the proposed method. The performance model used in the case study relies on the Supply Chain Operations Reference (SCOR) model level 1. With this measurement method, supply chain managers can easily benchmark the performance of the whole system, and then analyze the effectiveness and efficiency of the supply chain.

프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발 (Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique)

  • ;이건수;박강
    • 한국CDE학회논문집
    • /
    • 제17권3호
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

Self-Validating 지능형 센서를 사용한 디지털 제어기의 설계 (Design of Digital Controllers with Self-Validating Intelligent Sensors)

  • 나승유;배희종
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.51-54
    • /
    • 2000
  • We are concerned with processing methods of the measurement values of sensors in the control system. When some faults happen to sensor components, the measurement value of sensors cause the malfunction of the plant. So it is necessary to detect and reduce the influence of faults to control with reliability for the overall system. The sensor status must be always good for best demonstration of the controller performance. A self-validating sensor detects the sensor state from the measurement value, reconstruct a soft sensor and can improve reliability of the sensor. If sensor faults, the sensor is detected and reconstructed with the best estimate from its correlation to other sensors and historical data. It is applied to the control of a flexible link system with the sensor fault problems in the light sensor module for position to show the applicability. In this paper, we propose a digital controller which reduces deflection of the moving set-point by reconstructing output of a sensor when the sensor fault is detected.

  • PDF

DBB를 이용한 5축 복합가공기의 오차 측정 시스템 개발에 관한 연구 (The Development of An Error Measurement System of 5-Axis Mill & Turn Machine Tool by Double Ball Bar Test)

  • 김태한;정윤교;고해주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.243-244
    • /
    • 2006
  • In this paper, the development of an error measurement system of 5-axis mill & turn machine tool presented by double ball bar test, which has been widely used to measure the overall accuracy of machining center. and the reliability of an error measurement system of 5-axis mill & turn machine tool was secured by the direct cutting test.

  • PDF

한국의 보건지표 체계 개선에 관한 연구 (A study on development of health indicator system in Korea)

  • 윤치근;윤병준;이준협;김윤신
    • 보건행정학회지
    • /
    • 제13권2호
    • /
    • pp.44-66
    • /
    • 2003
  • I. Background and Purpose Health Indicator system and measurement of health status are an important fields in national health fields. This study reviewed the overall concepts of health and health indicators, health indicator system. The purposes of this study are to build the conceptual health framework, and suggest a health indicator system, in order to correspond to the situation of national health and the demand of International organizations. II. Scope and Contents The scope of this study ; - Review of tile conceptual health framework, health indicators, and health Indicator system - Selection and development of tile new individual health indicators - Suggestion of tile revised health indicator system III. Results of Study This study intented to build the conceptual and framework of national health and provide the measurement tools of health status. This study developed the health indicator system through the conceptual and hierarchial approach to national health. The health indicator system contains 6 concern: areas and each sub-areas. The major concern areas are health state and behavior, deathㆍdiseaseㆍdisability, health care utilization, health resources, health expenditure and finance, other affecting factors on health. This health indicator system is corresponding to the situation of health status patterns and the demand of international organizations. And this health indicator system is considering the present health data production system and the availability of health data.

초점면 배열 방식의 열상카메라 시스템의 구현 (Implementation of a Thermal Imaging System with Focal Plane Array Typed Sensor)

  • 박세화;원동혁;오세중;윤대섭
    • 제어로봇시스템학회논문지
    • /
    • 제6권5호
    • /
    • pp.396-403
    • /
    • 2000
  • A thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main part of the system is a thermal camera in which a focal plane array typed sensor is introduced. The sensor detects the mid-range infrared spectrum of target objects and then it outputs a generic video signal which should be processed to form a frame thermal image. Here, a digital signal processor(DSP) is applied for the high speed processing of the sensor signals. The DSP controls analog-to-digital converter, performs correction algorithms and outputs the frame thermal data to frame buffers. With the frame buffers can be generated a NTSC signal and transferred the frame data to personal computer(PC) for the analysis and a monitoring of the thermal scenes. By performing the signal processing functions in the DSP the overall system achieves a simple configuration. Several experimental results indicate the performance of the overall system.

  • PDF

머리전달함수 측정시스템의 개발과 분석 (Newly Designed HRTF Measurement System and its Analysis)

  • 이윤재;박영진;박윤식
    • 제어로봇시스템학회논문지
    • /
    • 제16권2호
    • /
    • pp.202-205
    • /
    • 2010
  • When we render 3D sound images using headphones or speakers, the main key of this technology is the Head-related transfer function (HRTF) database. Even though there are various HRTF databases, they have some drawbacks such as detrimental effects caused by imperfect measuring environment and insufficient measurement points. Moreover there is no database with Korean subjects. We are planning to develop the HRTF database for Korean. As a first step to establish the HRTF database aimed at Korean, the new HRTF measurement system with minimized aforementioned drawbacks is designed. In this paper, the newly designed HRTF measurement system is introduced and the overall effects caused by the diffraction of the apparatus, especially the headrest and backrest of the chair, are analyzed. The backrest of the chair does not distort the HRTFs significantly while the headrest makes significant distortion on the HRTFs and it could have significant effects on directional perception. We determined acceptable head rotation angle and head position of the subject for accurate HRTF measurement based on the experiments with B&K HATS. We conclude that the 3 degrees of the head rotation and the 1.5cm front/back/left/right shift of the head do not distort the HRTFs significantly.