• Title/Summary/Keyword: Over load test

Search Result 470, Processing Time 0.033 seconds

A Study on the In-Situ Measurement of the Deformation and the Back Calculation of the Load in the Mine Roadway Over-Stressed Rocks (중지압 운반 갱도내 변형계측 및 하중역산에 관한 연구)

  • Cho, Young-Soo;Kim, Hong-Woo;Shin, Hee-Soon;Chung, So-Keul;Lee, Hi-Keun
    • Tunnel and Underground Space
    • /
    • v.3 no.1
    • /
    • pp.40-49
    • /
    • 1993
  • In this study, the indirect estimation method of the support load which is based upon the integrated measuring technique suggested by Kovari was applied to the calculation of support load in the mine roadway. Four test supports were installed in the area where they had to be replaed. Two of those were GI-130 rigid supports and the others were U-26 yieldable supports. The vibrating wire strain gages which were attached inpairs on the steel arch support were used to provide an accurate measurement. Bending moments and normal forces obtained from strain gage pairs were used to calculate the support load. This method was also verified by laboratory bending tests. The results obtained from the back-calculction method showed relatively good agreement with the measured convergence for each crossection.

  • PDF

Characteristic Behavior of High-Strength Reinforced Concrete Bridge Column under Simulated Seismic Loading (고강도 철근콘크리트 교각의 내진거동특성)

  • Ra Hong-Seong;Lee Kyoung-Joon;Ryu Hyo-Jin;Hwang Sun-Kyoung;Lee Chin-Ok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.22-27
    • /
    • 2004
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement (ps = 0.96, 1.44 per cent) and axial load ratio (0.05, 0.1, 0.2 P/Po) and strength $(350kgf/cm^2,\;600kgf/cm^2)$. Test results show that bridge columns with 50 per cent higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour. For bridge columns with axial load ratio(P/Po) less than 0.2, the ratio of Mmax over Mad, nominal moment capacity predicted by ACI 318-02 provisions, is consistently greater than 1 with approximately a 20 percent margin of safty.

  • PDF

Full-scale experimental evaluation of a panelized brick veneer wall system under simulated wind loading

  • Liang, Jianhai;Memari, Ali M.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.1
    • /
    • pp.99-123
    • /
    • 2011
  • Brick veneer over steel stud backup wall is lighter and easier to construct compared to brick veneer over concrete masonry backup wall. However, due to the relatively low stiffness of the steel stud backup, the brick veneer tends to crack under wind load. This paper briefly introduces a new panelized brick veneer with steel frame backup wall system that is developed to potentially address this problem. The experimental study of the performance of this system under simulated wind loading is discussed in detail. The test setup details and the test specimens are introduced, results of major interests are presented, and performance of the new system is evaluated based on the test results.

A Study on the Vibration Characteristics for Safety Design of Vehicle Structure (차량 구조물 안전설계를 위한 진동특성에 관한 연구)

  • 신귀수;이기형
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.13-21
    • /
    • 1998
  • This is a study on the natural vibration characteristics of Vehicle frame. Nowadays, many trucks freight the over-load, do the car designers consider the over-load about 200% in the design. It's necessary to make the model of a vehicle and simulate it for the test of driving condition, durability and vibration behavior before the vehicle is manufactured. If it is possible to make a simulation using the static and dynamic analysis, this is very useful in accomplishing an optimal design of the vehicle. In this paper, we studied the vibration characteristics of a truck body frame. The automobile body frame model for experiment is made smaller than real size frame with the ratio of 1/10. The vibration characteristics of a frame is considered as one of main factors in analyzing and improving the problem for ride comfort, noise and vibration reduction. Therefore, we experimented two method to neglect the nonlinearity. First is bolting and second is welding at the joint section. We compared computer simulation results and experimental data.

  • PDF

Behavior of Geosynthetic Reinforced Modular Block Walls under Sustained Loading (지속하중 재하시 보강토 옹벽의 거동특성 - 축소모형실험)

  • Yoo, Chung-Sik;Kim, Sun-Bin;Byun, Jo-Seph;Kim, Young-Hoon;Han, Dae-Hui
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.121-130
    • /
    • 2006
  • Despite a number of advantages of reinforced earth walls over conventional concrete retaining walls, there exit concerns over long-term residual deformation when used as part of permanent structures. In view of these concerns, time-dependant deformation characteristics of geosynthetic reinforced modular block walls under sustained loads were investigated using reduced-scale model tests. The results indicated that a sustained load can yield appreciable magnitude of residual deformation, and that the magnitude of residual deformation depends on the loading characteristic as well as reinforcement stiffness.

  • PDF

Behavior of Geosynthetic Reinforced Modular Block Walls under Sustained Loading using Reduced-Scale Model Test (축소모형실험에 의한 지속하중하에서의 보강토 옹벽의 거동특성 연구)

  • Yoo, Chung-Sik;Kim, Sun-Bin;Byun, Joseph;Kim, Young-Hoon;Han, Dae-Hui
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Despite a number of advantages of reinforced earth walls over conventional concrete retaining walls, there exit concerns over long-term residual deformation when used as part of permanent structures. In view of these concerns, time-dependant deformation characteristics of geosynthetic reinforced modular block walls under sustained loads were investigated using reduced-scale model tests. The results indicated that a sustained load can yield appreciable magnitude of residual deformation, and that the magnitude of residual deformation depends on the loading characteristic as well as reinforcement stiffness.

  • PDF

Development of the Safety Steering System of Motor Vehicles Transmission (차량용 변속기의 조향안전화 제어장치의 개발)

  • 송창섭
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.2
    • /
    • pp.12-17
    • /
    • 1995
  • The operation of heavy tracked vehicle has the problems in the steering that made by misoperations. The protection device is applied to the vehicles. But that device is applied to the vehicles. But that device has the engine stop and over load condition problems. the steering safety system is developed on the basis of clutch slip that proved the durability in the dynamo test and field test. The steering safety system caused the performance improvement of vehicles when steering.

  • PDF

A Study on the Fuzzy ELDC of Composite Power System Based on Probabilistic and Fuzzy Set Theories

  • Park, Jaeseok;Kim, Hongsik;Seungpil Moon;Junmin Cha;Park, Daeseok;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.95-101
    • /
    • 2002
  • This paper illustrates a new fuzzy effective load model for probabilistic and fuzzy production cost simulation of the load point of the composite power system. A model for reliability evaluation of a transmission system using the fuzzy set theory is proposed for considering the flexibility or ambiguity of capacity limitation and overload of transmission lines, which are subjective matter characteristics. A conventional probabilistic approach was also used to model the uncertainties related to the objective matters for forced outage rates of generators and transmission lines in the new model. The methodology is formulated in order to consider the flexibility or ambiguity of load forecasting as well as capacity limitation and overload of transmission lines. It is expected that the Fuzzy CMELDC (CoMposite power system Effective Load Duration Curve) proposed in this study will provide some solutions to many problems based on nodal and decentralized operation and control of an electric power systems in a competitive environment in the future. The characteristics of this new model are illustrated by some case studies of a very simple test system.

Lateral Load Tests of A 10-Story Reinforced Concrete Frame with Nonseismic Details (비내진 상세를 가진 10층 철근 콘크리트 골조의 횡방향 가력 실험)

  • 이한선;강귀용;김정우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.525-530
    • /
    • 1998
  • The objective of this experiment is to observe the elastic and inelastic behaviors of high-rise reinforced concrete frames with nonseimic details. To do this, a building frame designed according to Korean seismic code and detailed in the Korean conventional manner was selected. An 1:12 scale plane frame model was manufactured according law. Reversed lateral load tests and monotonic push-over test were performed under the displacement control. To simulate the earthquake effect, the lateral force distribution was maintained to be an inversed triangular by using whiffle tree. From the tests, story displacements, lateral story forces, local plastic rotations and the relations between inter-story drift versus story shear are obtained. Based on the test results, conclusions on the characteristics of the elastic and behaviors of a high-rise reinforced concrete frame with nonseismic details are drawn.

  • PDF

Application of Rammed Aggregate Pier(Geopier) for Foundation Reinforcement of Structures (구조물 기초보강용 짧은 쇄석다짐말뚝(Geopier)의 적용성 및 활용방안에 관한 연구)

  • Joeng, Gyong-Hwan;Jung, Sun-Tae;Moon, Jun-Bai;Kim, Dong-Jun;Baek, Kyung-Jong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.479-488
    • /
    • 2005
  • Geopier soil reinforcement system which crushed aggregate is put into a hole and rammed the aggregate with tamper is a viable alternative to deep foundation to over-excavation and replacement. Also, Geopier is intermediate foundation of deep and shallow foundation. In this paper, the value of Geopier element stiffness modulus($K_g$) when designed is compared with the measured value($K_g$) by the in-situ modulus Load test in the field. Also, this paper presents a technology overview of system capabilities and application for foundation reinforcement of structures.

  • PDF