마이크로그리드의 운전조건을 고려한 과전류계전기 (The Over-current relay considering operating conditions of the micro-grid)

  • 강용철;강해권;차선희;장성일;이병은;김용균;박군철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.484-485
    • /
    • 2008
  • A micro-grid (MG) is a new concept to aggregate distributed generations (DGs) and loads in a small area. The difference between MG and DG is that MG can supply power to loads even in islanding conditions. The magnitude of the fault current depending on interconnection between the MG and utility and the number of DGs in the MG. Therefore, the setting value of the OCR must be changed depending on operating conditions of the MG. This paper proposes the over-current relay considering operating conditions of the MG. In the proposed algorithm, the supervisory control and data acquisition decides the operating conditions of the MG and sends the proper setting values to each OCR. The performance of the algorithm was investigated in the case of the various operating conditions.

  • PDF

Outage Analysis of OFDM-Based Cognitive AF Relay Network in the Presence of Narrowband Interference

  • Rajkumar, Samikkannu;Senthilkumaran, V.N.;Thiruvengadam, S.J.
    • ETRI Journal
    • /
    • 제37권3호
    • /
    • pp.460-470
    • /
    • 2015
  • Orthogonal frequency-division multiplexing (OFDM) is one of the most widely used technologies in current wireless communication systems and standards. Cognitive radio (CR) provides a robust solution to the problem of spectrum congestion as it offers opportunistic usage of frequency bands that are not occupied by primary users. Due to the underlying sensing, spectrum shaping, scaling, and interoperable capabilities of OFDM, it has been adapted as a best transmission technology for CR wireless systems. However, the performance of an OFDM-based CR wireless system is affected by the existence of narrowband interference (NBI) from other users. Further, due to carrier frequency offset in NBI sources, NBI energy may spread over all subcarriers of an OFDM signal. In this paper, a fixed Amplify-and-Forward (AF) relay that operates at a frequency band that is different from that of direct mode is introduced to suppress the effect of NBI. Analytical expressions are derived for outage probability in direct, AF-relay, and incremental relaying modes. The outage performance of the proposed AF relay-based CR network is proven to be better than that of direct mode.

비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구 (A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection)

  • 김경철;고훈
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

Wavelet 변환을 이용한 디지털 거리계전 알고리즘 (A Digital Distance Relaying Algorithm using a Wavelet Transformation)

  • 강상희;이주훈;남순열;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1215-1221
    • /
    • 1999
  • A high speed digital distance relaying algorithm based on a Wavelet Transformation is proposed. To obtain stable phasor values very quickly, first, a lowpass filter which has low cutoff frequency is used. Secondly, db2(Daubechies 2) Wavelet which has the data window of 4 samples is used. A FIR filter which removes the DC-offset component in current relaying signals is applied. In accordance with a series of tests, the operation time of the relaying algorithm is less than 3/4 cycles after faults in a 80 [km], 154[kV], 60[Hz] over-head transmission line system.

  • PDF

An Energy Saving Cooperative Communications Protocol without Reducing Spectral Efficiency for Wireless Ad Hoc Networks

  • 단디쉬엔;공형윤
    • 한국통신학회논문지
    • /
    • 제34권2A호
    • /
    • pp.107-112
    • /
    • 2009
  • Spectral efficiency of current two-phase cooperative communications protocols is low since in the second time the relay forwards the same signal received from the source to the destination, the source keeps silent in this time. In this paper, we propose a novel cooperative communications protocol where the signal needed to transmit to the destination is sent in both phases, the source and the relay also transmit different signal to the destination thus no loss of spectral efficiency. This protocol performs signal selection based on log-likelihood ratio (LLR) at relay and maximum likelihood (ML) detection at destination. While existing protocols pay for a worse performance than direct transmission in the low SNR regime which is of special interest in ad hoc networks, ours is better over the whole range of SNR. In addition, the proposal takes advantages of bandwidth efficiency, long delay and interference among many terminals in ad hoc network. Simulation results show that the proposed protocol can significantly save total energy for wireless ad hoc networks.

멀티 에이전트 시스템 (Multi-Agent System)을 이용한 배전계통의 적응 과전류보호 (Multi-Agent System having Adaptive Over Current Protection Function for Power Distribution Systems)

  • 장중구;이승재;임동진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.365-372
    • /
    • 2001
  • This paper presents a new protection concept to achieve the adaptive optimal function by introducing the multi-agent system technology. Making each relay an agent which consists of relay agent module and coordinator module, each agent works autonomously to improve protection capability by cooperating with other agents. It is applied to the overcurrent protection system of the industrial power system in order to show the feasibility of the proposed methodology.

  • PDF

PER Analysis for Cooperative Multi-Hop Transmission Protocol over Nakagami-m Fading Channels

  • Duy, Tran Trung;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제12권3호
    • /
    • pp.189-195
    • /
    • 2012
  • In this paper, we propose a novel protocol called a Multi-hop Diversity Transmission protocol in which the retransmission is realized by a relay that is Nearest to a current Source (MDTNS). We derive the mathematical expressions of the packet error rate (PER) and the average number of transmissions over Nakagami-m fading channels, and verify them by Monte Carlo simulations. The simulation results show that the MDTNS protocol improves the performance of the network in terms of PER when compared to the Multi-hop Diversity Transmission protocol in which the retransmission is done by a relay that is Nearest to Destination (MDTND) and to the conventional multi-hop transmission (CMT) protocol.

SC 전용 보호계전기 개발 (Research for Protection Relay of Static Condenser Bank)

  • 정재기;윤시영;김석중;김근규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.48-50
    • /
    • 2006
  • SC(Static Condenser) in KEPCO is used in voltage control and power factor compensation. Currently KEPCO uses SC to 154kv 50MVA and 23kv SMVA. It is not important in old days because a SC bank accident has no effect on power system. But we are interested in the SC bank for power quality in these days. The SC Bank has a reactor and a condenser using series connection. It is operated in critical point for resonance circuit normally. Therefore the SC bank has a small reliability against other Power instruments. If a 4th harmonic frequency as a resonance frequency is supplied in system, the condenser is damaged because of a resonance current. And a trip and a closing for CB(Circuit Breaker) in many times will have a big influence of SC bank destruction. General OCR(Over Current Relay) observing SC bank is not useful for this protection We think that protection relay must be have the SC bank characteristics. A solution for this problem is active Power, resonance frequency and impedance.

  • PDF

과전류 보호계전기용 광섬유 전류센서 (Fiber-Optic Current Transformer for the Over Current Protection Relay)

  • 송민호;양창순;안성준;박병석;이병호
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.542-548
    • /
    • 2001
  • 과전류 보호계전기에 사용할 목적으로 광섬유를 센서헤드로 사용하는 광 전류센서를 구성하였다. 전류측정의 원리는 도체 주변에 감겨진 광섬유 코일을 따라 광신호의 선형편광축이 자기장에 의하여 회전하는 정도를 측정하여 이로부터 전류의 값을 산출하는 편광측정 방법이 사용되었다. 센서코일은 $10/125{\mu}m$ 규격의 일반 통신용 광섬유를 미터당 20회전 이상 비틀어 제작하여 온도나 진동 등의 환경적 영향을 최소화하였다. 코일의 한쪽 끝은 Faraday Rotator Mirror를 장착한 반사형으로 설계하여 계통을 해체하지 않은 상태에서도 센서의 탈 부착이 가능하고 코일의 회전수에 따라 센서의 민감도 조절이 용이하며 폐회로형 구조이므로 인근 신호원에 의한 간섭을 차단할 수 있다. 편광 빛가르개 등을 이용한 광학 신호처리부를 구성하고 표준 전류원을 이용한 전류측정 실험을 수행한 결과로 이론적인 해석과 동일한 형태의 출력을 얻을 수 있었다. 본 논문에서는 구성한 광 전류센서의 이론적 모델을 기술하고 전류측정 실험의 결과와 이론치에 대하여 비교 분석한다.

  • PDF

An Autonomous Optimal Coordination Scheme in a Protection System of a Power Distribution Network by using a Multi-Agent Concept

  • Hyun, Seung-Ho;Min, Byung-Woon;Jung, Kwang-Ho;Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a protection system using a Multi-Agent concept for power distribution networks is proposed. Every digital over current relay(OCR) is developed as an agent by adding its own intelligence, self-tuning and communication ability. The main advantage of the Multi-Agent concept is that a group of agents work together to achieve a global goal which is beyond the ability of each individual agent. In order to cope with frequent changes in the network operation condition and faults, an OCR agent, suggested in this paper, is able to detect a fault or a change in the network and find its optimal parameters for protection in an autonomous manner considering information of the whole network obtained by communication between other agents. Through this kind of coordination and information exchanges, not only a local but also a global protective scheme is completed. Simulations in a simple distribution network show the effectiveness of the suggested protection system.