• Title/Summary/Keyword: Over Sampling

Search Result 1,282, Processing Time 0.038 seconds

Ichthyoplankton Detection Proportion and Margin of Error for the Scomber japonicus in Korean Coastal Seas

  • Kim, Sung;Cho, Hong-Yeon
    • Ocean and Polar Research
    • /
    • v.39 no.2
    • /
    • pp.73-84
    • /
    • 2017
  • The probability distribution of ichthyoplankton is important for enhancing the precision of sampling while reducing unnecessary surveys. To estimate the ichthyoplankton detection proportion (IDP) and its margin of error (ME), the monitoring information of the chub mackerel's (Scomber japonicus) ichthyoplankton presence-absence sampling data has been were collected over approximately 30 years (from 1982 to 2011) in the Korean coastal seas. Based on the computed spatial distributions of the mackerel's IDP and ME, the confidence interval (CI) range, defined as 2 ME, decreases from approximately 80% to 40% as the sample size n increases from 4 to 24 and the ME is approximately 40% in the typical (seasonal survey) case n = 4 per year. The IDP and ME off Jeju Island are relatively high at the 0.5-degree smoothing level. After increasing the spatial smoothing level to 1.0-degree, the ME decreased, and the spatial distribution pattern also changed due to the over-smoothing effects. In this study, the 0.5-degree smoothing is more suitable for the distribution pattern than the 1.0-degree smoothing level. The area of the high IDP and the low ME on the mackerel's ichthyoplankton was similar to the estimated spawning ground in the Korean peninsula. This information could contribute to enhancing for the spawning ecology surveys.

High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals (오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템)

  • Kim, Nam-Hun;Kim, Min-Heui;Choi, Chang-Ho;Lee, Sang-Hoon;Choi, Keyng-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

The Study of Constraint Factors to Leisure Sports Participation Degree in Silver Class (실버계층의 레저스포츠 참여정도와 제약요인에 관한 연구)

  • Kim, sung-hun;Choi, woong-jae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.270-273
    • /
    • 2008
  • The point of the meaning, this study selects population which is aged over 65 and new silver generation who is aged between 55 to 64. The objects were selected by purposeful sampling method and the 933 objects who participated in leisure sports age over 55 were used for this thesis's analysis. The results of the study were as follow; First, the weekly participation frequency was physical psychological burden, facilities, information technology, interpersonal relations, concern lack, time lack, bear. there was statistically significant difference. Second, the daily workout time was physical psychological burden, facilities, information technology, interpersonal relations, concern lack, time lack, bear. there was statistically significant difference. Third, the participant experience was physical psychological burden, facilities, information technology, interpersonal relations, concern lack, time lack, bear. there was statistically significant difference.

  • PDF

A Protection Method using Destination Address Packet Sampling for SYN Flooding Attack in SDN Environments (SDN 환경에서의 목적지 주소별 패킷 샘플링을 이용한 SYN Flooding 공격 방어기법)

  • Bang, Gihyun;Choi, Deokjai;Bang, Sangwon
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2015
  • SDN(Software Defined Networking) has been considered as a new future computer network architecture and DDoS(Distributed Denial of Service) is the biggest threat in the network security. In SDN architecture, we present the technique to defend the DDoS SYN Flooding attack that is one of the DDoS attack method. First, we monitor the Backlog queue in order to reduce the unnecessary monitoring resources. If the Backlog queue of the certain server is occupied over 70%, the sFlow performs packet sampling with the server address as the destination address. To distinguish between the attacker and the normal user, we use the source address. We decide the SYN packet threshold using the remaining Backlog queue that possible to allow the number of connections. If certain sources address send the SYN packet over the threshold, we judge that this address is attacker. The controller will modify the flow table entry to block attack traffics. By using this method, we reduce the resource consumption about the unnecessary monitoring and the protection range is expanded to all switches. The result achieved from our experiment show that we can prevent the SYN Flooding attack before the Backlog queue is fully occupied.

0.11-2.5 GHz All-digital DLL for Mobile Memory Interface with Phase Sampling Window Adaptation to Reduce Jitter Accumulation

  • Chae, Joo-Hyung;Kim, Mino;Hong, Gi-Moon;Park, Jihwan;Ko, Hyeongjun;Shin, Woo-Yeol;Chi, Hankyu;Jeong, Deog-Kyoon;Kim, Suhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.3
    • /
    • pp.411-424
    • /
    • 2017
  • An all-digital delay-locked loop (DLL) for a mobile memory interface, which runs at 0.11-2.5 GHz with a phase-shift capability of $180^{\circ}$, has two internal DLLs: a global DLL which uses a time-to-digital converter to assist fast locking, and shuts down after locking to save power; and a local DLL which uses a phase detector with an adaptive phase sampling window (WPD) to reduce jitter accumulation. The WPD in the local DLL adjusts the width of its sampling window adaptively to control the loop bandwidth, thus reducing jitter induced by UP/DN dithering, input clock jitter, and supply/ground noise. Implemented in a 65 nm CMOS process, the DLL operates over 0.11-2.5 GHz. It locks within 6 clock cycles at 0.11 GHz, and within 17 clock cycles at 2.5 GHz. At 2.5 GHz, the integrated jitter is $954fs_{rms}$, and the long-term jitter is $2.33ps_{rms}/23.10ps_{pp}$. The ratio of the RMS jitter at the output to that at the input is about 1.17 at 2.5 GHz, when the sampling window of the WPD is being adjusted adaptively. The DLL consumes 1.77 mW/GHz and occupies $0.075mm^2$.

Determination of moisture threshold for solution sampling in different soil texture (토양용액 채취를 위한 토성별 한계수분함량 설정)

  • Lee, Chang Hoon;Kim, Myung Sook;Kong, Myung Seok;Kim, Yoo Hak;Oh, Taek-Keun;Kang, Seong Soo
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.399-404
    • /
    • 2014
  • Soil moisture is an important factor for the availability and circulation of nutrients in arable soil. The purpose of this study was to set thresholds moisture content on soil nitrate concentration in the solution for real-time diagnosis. Sandy loam, silt loam, and sandy loam was filled with $1.2g\;cm^{-3}$ at Wagner pots, 0, 100, and $200mg\;L^{-1}$ of $KNO_3$ was saturated. Nitrate in standard solution was recovered about 95% by passing the porous cup. Nitrate concentrations in sampling of soil solution were examined by using a porous cup. The soil solution was higher in accordance with sandy loam> silt loam> clay loam, limited water filled pore space for sampling soil solution was 33.7, 56.4, and 62.2%, respectively. Nitrate concentration in the soil solution was negligible at sandy loam and silt loam during sampling periods, which was decreased about 50~82% in clay loam compared to the initial $NO_3$-N concentration in the saturated $KNO_3$ solution. Over limitation of soil solution sampling, soil EC and $NO_3$-N content were increased with the saturated $NO_3$-N concentration, regardless of soil texture (p<0.05). Conclusively, soil solution by using a porous cup was possible, regardless of the soil texture, which was useful for the diagnosis in nitrate concentration of soil solution. However, because nitrate concentration of soil solution in a clay loam changes, it was necessary for careful attention in order to take advantage for the real-time diagnosis of nitrogen management in soil.

Real-time Localization of An UGV based on Uniform Arc Length Sampling of A 360 Degree Range Sensor (전방향 거리 센서의 균일 원호길이 샘플링을 이용한 무인 이동차량의 실시간 위치 추정)

  • Park, Soon-Yong;Choi, Sung-In
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.6
    • /
    • pp.114-122
    • /
    • 2011
  • We propose an automatic localization technique based on Uniform Arc Length Sampling (UALS) of 360 degree range sensor data. The proposed method samples 3D points from dense a point-cloud which is acquired by the sensor, registers the sampled points to a digital surface model(DSM) in real-time, and determines the location of an Unmanned Ground Vehicle(UGV). To reduce the sampling and registration time of a sequence of dense range data, 3D range points are sampled uniformly in terms of ground sample distance. Using the proposed method, we can reduce the number of 3D points while maintaining their uniformity over range data. We compare the registration speed and accuracy of the proposed method with a conventional sample method. Through several experiments by changing the number of sampling points, we analyze the speed and accuracy of the proposed method.

Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle - a Clinical Trial

  • Sanam, Moradan;Majid, Mir Mohammad Khani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4971-4975
    • /
    • 2015
  • Background: Several methods have been presented for the evaluation of the endometrium in patients with abnormal uterine bleeding, which include minimal invasive and invasive approaches such as diagnostic curettage or endometrial biopsy by Pipelle. Many studies have been performed in order to compare two methods; diagnostic curettage and outpatient endometrial biopsy. This investigation compared sampling adequacy, endometrial histopathology, failure rates, duration and costs between diagnostic curettage in a hospital and endometrial biopsy. Materials and Methods: This single blind clinical trial was performed on 130 patients older than 35 years who was referred to Amir training hospital in 2013 for elective diagnostic curettage because of abnormal uterine bleeding. For all patients eligible for the study, an endometrial sample by Pipelle was taken without anesthesia or dilatation. Then under general anesthesia diagnostic curettage was performed by sharp curette. Sampling duration was calculated and both samples were sent to the same pathologist. The diagnostic values of two methods in the diagnosis of normal endometrium, endometrial hyperplasia and carcinoma were compared. The costs of these two methods were also compared. Data analysis was performed by SPSS (version 16.0) software. Chi-Square, Fisher, and Pearson tests were used and were considered statistically significant at P values less than 0.05. Results: Two methods were agreed upon 88% of sampling adequacy and 94% of pathological results. Specificity of 100% and sensitivity of 90% for detection of proliferative endometrium, secretory endometrium, simple hyperplasia without atypia and 100% for cancer were recorded. Pipelle diagnostic accuracy in comparison with curettage, have been reported over 97%, so the failure rate in this study was below 5%. Sensitivity of Pipelle for detection of atrophic endometrium was reported below 50%. Duration and cost was lower in Pipelle versus curettage. Conclusions: It is concluded that due to high agreement and cohesion coefficient between curettage and Pipelle on the issue of sampling adequacy, histopathology finding (except atrophic endometrium), low failure rate, duration of sampling and cost, Pipelle can be introduced as a suitable alternative of diagnostic curettage.

Applications of Cryogenic Method to Water Vapor Sampling from Ambient Air for Isotopes Analysis (수증기 동위원소 측정을 위한 저온채집법에 대한 연구)

  • Kim, Songyi;Han, Yeongcheol;Hur, Soon-Do;Lee, Jeonghoon
    • Ocean and Polar Research
    • /
    • v.38 no.4
    • /
    • pp.339-345
    • /
    • 2016
  • Stable water vapor isotopes have been utilized as a tracer for studying atmospheric global circulations, climate change and paleoclimate with ice cores. Recently, since laser spectroscopy has been available, water vapor isotopes can be measured more precisely and continuously. Studies of water vapor isotopes have been conducted over the world, but it is the early stage in south Korea. For vapor isotopes study, a cryogenic sampling device for water vapor isotopes has been developed. The cryogenic sampling device consists of the dewar bottle, filled with extremely low temperature material and impinger connected with a vacuum pump. Impinger stays put in the dewar bottle to change the water vapor which passes through the inside of impinger into the solid phase as ice. The fact that water vapor has not sampled completely leads to isotopic fractionation in the impinger. To minimize the isotopic fractionation during sampling water vapor, we have tested the method using a serial connection with two sets of impinger device in the laboratory. We trapped 98.02% of water vapor in the first trap and the isotopic difference of the trapped water vapor between two impinger were about 20‰ and 6‰ for hydrogen and oxygen, respectively. Considering the amount of water vapor trapped in each impinger, the isotopic differences for hydrogen and oxygen were 0.33‰ and 0.06‰, respectively, which is significantly smaller than the precision of isotopic measurements. This work can conclude that there is no significant fractionation during water vapor trapping.

Effects of Latin hypercube sampling on surrogate modeling and optimization

  • Afzal, Arshad;Kim, Kwang-Yong;Seo, Jae-won
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.3
    • /
    • pp.240-253
    • /
    • 2017
  • Latin hypercube sampling is widely used design-of-experiment technique to select design points for simulation which are then used to construct a surrogate model. The exploration/exploitation properties of surrogate models depend on the size and distribution of design points in the chosen design space. The present study aimed at evaluating the performance characteristics of various surrogate models depending on the Latin hypercube sampling (LHS) procedure (sample size and spatial distribution) for a diverse set of optimization problems. The analysis was carried out for two types of problems: (1) thermal-fluid design problems (optimizations of convergent-divergent micromixer coupled with pulsatile flow and boot-shaped ribs), and (2) analytical test functions (six-hump camel back, Branin-Hoo, Hartman 3, and Hartman 6 functions). The three surrogate models, namely, response surface approximation, Kriging, and radial basis neural networks were tested. The important findings are illustrated using Box-plots. The surrogate models were analyzed in terms of global exploration (accuracy over the domain space) and local exploitation (ease of finding the global optimum point). Radial basis neural networks showed the best overall performance in global exploration characteristics as well as tendency to find the approximate optimal solution for the majority of tested problems. To build a surrogate model, it is recommended to use an initial sample size equal to 15 times the number of design variables. The study will provide useful guidelines on the effect of initial sample size and distribution on surrogate construction and subsequent optimization using LHS sampling plan.