• 제목/요약/키워드: Over Load

검색결과 2,146건 처리시간 0.031초

Thyristor를 이용한 교류과전류 차단에 관한 연구 (A study on AC over-current breaker using thyristor)

  • 박민호;심재명
    • 전기의세계
    • /
    • 제28권7호
    • /
    • pp.49-55
    • /
    • 1979
  • 본논문은 Thyristor를 이용하여 교류회로의 고장전류를 차단하는 기구에 대한 것이다. 즉 Thyristor 한류차단회로를 설정하고 게이트제어회로 과전류검출기를 설계하고 동작과정을 확인하였다. 결과에 있어서 (1) 고속차단이 가능하다(60Hz 교류에서 4ms이내) (2) 이 방식에 의하면 차단용량을 감소시킬 수 있다. (3) 적은 신호로 지체없이 동작한다. (4) 기계적부분이 없으므로 반영구시 수명을 가진다.

  • PDF

Ductility and strength assessment of HSC beams with varying of tensile reinforcement ratios

  • Mohammadhassani, Mohammad;Suhatril, Meldi;Shariati, Mahdi;Ghanbari, Farhad
    • Structural Engineering and Mechanics
    • /
    • 제48권6호
    • /
    • pp.833-848
    • /
    • 2013
  • Nine rectangular-section of High Strength Concrete(HSC) beams were designed and casted based on the American Concrete Institute (ACI) code provisons with varying of tensile reinforcement ratio as (${\rho}_{min}$, $0.2_{{\rho}b}$, $0.3_{{\rho}b}$, $0.4_{{\rho}b}$, $0.5_{{\rho}b}$, $0.75_{{\rho}b}$, $0.85_{{\rho}b}$, $_{{\rho}b}$, $1.2_{{\rho}b}$). Steel and concrete strains and deflections were measured at different points of the beam's length for every incremental load up to failure. The ductility ratios were calculated and the moment-curvature and load-deflection curves were drawn. The results showed that the ductility ratio reduced to less than 2 when the tensile reinforcement ratio increased to $0.5_{{\rho}b}$. Comparison of the theoretical ductility coefficient from CSA94, NZS95 and ACI with the experimental ones shows that the three mentioned codes exhibit conservative values for low reinforced HSC beams. For over-reinforced HSC beams, only the CSA94 provision is more valid. ACI bending provision is 10 percent conservative for assessing of ultimate bending moment in low-reinforced HSC section while its results are valid for over-reinforced HSC sections. The ACI code provision is non-conservative for the modulus of rupture and needs to be reviewed.

V2G 시스템을 위한 보조 LC 회로를 가진 고효율 양방향 공진형 컨버터 (A High Efficiency Bidirectional Resonant Converter With Auxilary LC Circuit for V2G System)

  • 트란덕홍;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.323-324
    • /
    • 2016
  • In this paper a high efficiency bidirectional resonant converterfor Vehicle-to-Grid applications (V2G) is proposed.The proposed converter has adopted an LC auxiliary circuit in the third winding of the transformer. With the proposed method full softswitching can be ensured in all switches over a wide range of loadsand the secondary ringing can be removed with no additional snubber or clamp circuitry.In addition, since the proposed resonant converter is able to operate at an almost constant resonant frequencyregardless of the load, CC/CV charge of the battery can be simply implemented with high efficiency. A 3.3 kW bidirectional converter for On-Board Charger of Electric Vehicle is implemented to verify the validity of the proposed method. The experimental results show the high efficiency characteristics of the proposed converter over the wide range of load in both charge and discharge mode. The maximum efficiency of the proposed system was 98.13 % at 2.3 kW during the constant voltage mode charge operation.

  • PDF

축소모형실험에 의한 지속하중하에서의 보강토 옹벽의 거동특성 연구 (Behavior of Geosynthetic Reinforced Modular Block Walls under Sustained Loading using Reduced-Scale Model Test)

  • 유충식;김선빈;변요셉;김영훈;한대희
    • 한국지반신소재학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2006
  • 보강토 옹벽이 콘크리트 옹벽에 비해 다양한 이점을 가짐에도 불구하고 영구구조물로서 지속하중이 작용하는 경우에 대해 장기변형이 발생할 소지가 있다는 우려가 있다. 본 논문에서는 이러한 관점에서 축소모형실험을 실시하여 수집된 보강토 옹벽의 장기변형 메카니즘에 대한 내용을 다루었다. 실험결과 지속하중이 작용하는 경우에 있어 장기적으로 잔류변형이 발생할 우려가 있는 것으로 나타났으며 이는 지속하중의 특성과 보강재 강성에 따라 좌우되는 것으로 나타났다.

  • PDF

터빈 동익 스퀼러팁 표면에서의 열(물질)전달 특성 (Heat/Mass Transfer Characteristics on the Squealer Tip Surface of a Turbine Rotor Blade)

  • 문현석;이상우
    • 한국유체기계학회 논문집
    • /
    • 제12권1호
    • /
    • pp.35-42
    • /
    • 2009
  • The flow and heat/mass transfer characteristics on the squealer tip surface of a high-turning turbine rotor blade have been investigated at a Reynolds number of $2.09{\times}10^5$, by employing the oil-film flow visualization and naphthalene sublimation technique. The squealer rim height-to-chord ratio and tip gap height-to-chord ratio are fixed as typical values of $h_{st}/c$ = 5.5% and h/c = 2.0%, respectively, for turbulence intensities of Tu = 0.3% and 15%. The results show that the near-wall flow phenomena within the cavity of the squealer tip are totally different from those over the plane tip. There are complicated backward flows from the suction side to the pressure side near the cavity floor, in contrast to the plane tip gap flows moving toward the suction side after flow separation/reattachment. The squealer tip provides a significant reduction in tip surface thermal load with less severe gradient compared to the plane tip. In this study, the tip surface is divided into six different regions, and transport phenomena at each region are discussed in detail. The mean thermal load averaged over the squealer cavity floor is augmented by 7.5 percents under the high inlet turbulence level.

설계하중 및 고온을 받은 초고강도 콘크리트의 잔존압축강도 및 변형 특성 평가 (Evaluation on Residual Compressive Strength and Strain Properties of Ultra High Strength Concrete with Design Load and Elevated Temperature)

  • 윤민호;김규용;남정수;윤종일;배창오;최경철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.263-264
    • /
    • 2012
  • In this study, the ultra high strength concrete which have 100, 150, 200MPa took the heat from 20℃ to 70 0℃ and the 0, 20% stress in normal condition's to evaluate stress-strain, residual compressive strength and thermal expansion deformation were evaluated. The heating speed of specimen was 0.77℃/min 20~50℃, 50℃ before the target temperature, and the other interval's heating speed was 1℃/min. As a result, the stress-strain curve of non-load specimen showed the liner behavior at high temperature when the specimen's strength increased more. If ultra high strength concrete got loads, its compressive strength tended to decrease different from the normal strength concrete. The thermal expansion deformation was expanded from a vitrification of quartz over 500℃. however, over the 600℃, it was shrinked because of the dehydration of the combined water.

  • PDF

Experimental studies and numerical analysis of the shear behavior of fin plates to tubular columns at ambient and elevated temperatures

  • Jones, M.H.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.179-200
    • /
    • 2008
  • This paper reports the results of a recent experimental study into the behavior of welded fin-plate connections to both hollow and concrete filled tubular (CFT) columns under shear. Experiments have been performed at both ambient and elevated temperatures with the aid of an electric kiln. The observed failure modes include fracture of the fin plate and tearing out of the tube around the welds. By considering the results of previously published research, the current design method for similar connections under purely tensile load, in CIDECT Guide 9, based on a deformation limit of 3% of the tube width is shown to be inadequate when evaluating the ultimate strength of such connections. By comparing the results from the current test program which failed in the fin-plate with Eurocode guidance for failure of a fin-plate alone under shear and bending load it is shown that the column face influences the overall connection strength regardless of failure mode. Concrete in-fill is observed to significantly increase the strength of connections over empty specimens, and circular column specimens were observed to exhibit greater strength than similarly proportioned square columns. A finite element (F.E.) model, developed using ABAQUS, is presented and validated against the experimental results in order that extensive parametric tests may be subsequently performed. When validating the model against elevated temperature tests it was found that using reduction factors suggested in published research for the specific steel grades improved results over applying the generic Eurocode elevated temperature steel strength reduction factors.

블록의 변형을 고려한 T형 리프팅 러그의 강도 평가 (Strength Assessment of T-type Lifting Lugs Considering Deformation of Blocks)

  • 이주성;김민술
    • 한국해양공학회지
    • /
    • 제29권4호
    • /
    • pp.309-316
    • /
    • 2015
  • Lifting lugs are frequently used in shipyards to transport and turn over the blocks of ships and offshore structures. With the development of shipbuilding technology, blocks have increased in size, and block management technology has assumed a more important role in shipbuilding to enhance the productivity. For the sake of economics, as well as the safe design of a lug structure, a more rational design procedure based on a rigorous structural analysis is needed. This study investigated the strength characteristics of T-type lugs, considering the influence of blocks on which lugs are attached, by varying the in-plane and out-of-plane load direction. In this paper, the ultimate strength is also addressed for cases that include or do not include blocks in the strength analysis. In the present results, when there was a load acting in the normal direction to the block surface, the strength characteristics became poor, and the ultimate strength decreased. This paper ends by describing the need for further study to develop a more rational design for a lug structure.

A Family of Magnetic Coupling DC-DC Converters With Zero-Voltage-Switching Over Wide Input Voltage Range and Load Variation

  • Chen, Guipeng;Dong, Jie;Deng, Yan;Tao, Yong;He, Xiangning;Wang, Yousheng
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1639-1649
    • /
    • 2016
  • This paper presents a family of soft-switching DC-DC converters with a simple auxiliary circuit consisting of a coupled winding and a pair of auxiliary switch and diode. The auxiliary circuit is activated in a short interval and thus the circulating conduction losses are small. With the auxiliary circuit, zero-voltage-switching (ZVS) and zero-current-switching are achieved for the main and auxiliary switches respectively, over wide input voltage range and load variation. In addition, the reverse-recovery problem of diodes is significantly alleviated because of the leakage inductor. Furthermore, the coupled inductor simultaneously serves as the main and auxiliary inductors, contributing to reduced magnetic component in comparison with the conventional zero-voltage-transition (ZVT) converters. Experimental results based on a 500 W prototype buck circuit validate the advantages and effectiveness of the proposed magnetic coupling ZVS converter.

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 2: verification

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.735-751
    • /
    • 2014
  • In the previous paper, authors proposed the unified equivalent frame method (UEFM) for the lateral behavior analysis of the flat plate structure subjected to the combined gravity and lateral loads, in which the rotations of torsional members were distributed to the equivalent column and the equivalent slab according to the relative ratio of gravity and lateral loads. In this paper, the lateral behavior of the multi-span flat plate structures under various levels of combined gravity and lateral loads were analyzed by the proposed UEFM, which were compared with test results as well as those estimated by existing models. In addition, to consider the stiffness degradation of the flat plate system after cracking, the stiffness reduction factors for torsional members were derived from the test results of the interior and exterior slab-column connection specimens, based on which the simplified nonlinear push-over analysis method for flat plate structures was proposed. The simplified nonlinear analysis method provided good agreements with test results and is considered to be very useful for the practical design of the flat plate structures under the combined gravity and lateral loads.