• Title/Summary/Keyword: Over Load

Search Result 2,144, Processing Time 0.027 seconds

Studies on the Development of Bearing Capacity Reinforcement for the Foundation of Soil (기초지반의 지지력보강공법에 관한 연구)

  • 유동환;최예환;유연택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.1
    • /
    • pp.38-49
    • /
    • 1988
  • This paper presented as follows results of laboratory model tests with various shaped footings on soil bed reinforced with the strips on the base of behaviour of soil structure according to the loads and triaxial test results reinforced with geotextiles. Their parameters studied were the effects on the bearing capacity of a footing of the first layer of reinforcement, horizontal and vertical spacing of layers, number of layers, tensile strength of reinforcement and iclination load to the vertical 1.Depending on the strip arrangement, ultimate bearing capacity values could be more improved than urreinforced soil and the failure of soil was that the soil structure was transfered from the macrospace to microspase and its arrangement, from edge to edge to face to face. 2.The reinforcement was produced the reinforcing effects due to controlling the value of factor of one and permeable reinforcement was never a barrier of drainage condition. 3.Strength ratio was decreased as a linear shape according to increment of saturation degree of soil used even though at the lower strength ratio, the value of M-factor was rot influenced on the strength ratio but impermeable reinforcement decreased the strength of bearing capacity. 4.Ultimate bearing capacity under the plane-strain condition was appeared a little larger than triaxial or the other theoretical formulars and the circular footing more effective. 5.The maximum reinforcing effects were obtained at U I B=o.5, B / B=3 and N=3, when over that limit only acting as a anchor, and same strength of fabric appeared larger reinforcing effects compared to the thinner one. 6.As the LDR increased, more and more BCR occurred and there was appeared a block action below Z / B=O.5, but over the value, decrement of BCR was shown linear relation, and no effects above one. 7.The coefficient of the inclination was shown of minimum at the three layers of fabrics, but the value of H / B related to the ultimate load was decreased as increment of inclination degree, even though over the value of 4.5 there wasn't expected to the reinforcing effects As a consequence of the effects on load inclination, the degree of inclination of 15 per cent was decreased the bearing capacity of 70 per cent but irnproved the effects of 45 per cent through the insertion of geotextile.

  • PDF

Improved Load Sharing Rate in Paralleled Operated Lead Acid Batteries (납 축전지의 병렬운전시 부하분담률 개선)

  • 반한식;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.34-42
    • /
    • 2001
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the required voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. Because the voltage droop down in one set of battery is faster than in tow one, it amy result in the low efficiency of power converter with the voltage drop and cause the system shutdown. However, when the system being driven in parallel, a circular-current can be generated. The changing current differs in each set of battery because the system including batteries, rectifiers and loads is connected in parallel and it makes the charge voltage constant. It is shown that, as a result the new batteries are heated by over-charge and over-discharge, and the over charge current increases rust of the positive grid and consequently shortens the lifetime of the new batteries. The difference between the new batteries and old ones is the amount of internal resistance. In this paper, we can detect the unbalance current using the micro-processor and achieve the balance current by adjusting resistance of each set. The internal resistance of each set becomes constant and the current of charge and discharge comes to be balanced by inserting the external resistance into the system and calculating the change of internal resistance.

  • PDF

Seismic Performance and Flexural Over-strength of Hollow Circular RC Column with Longitudinal Steel Ratio 2.017% (축방향철근비 2.017%인 중공 원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Three small scale hollow circular reinforced concrete columns with aspect ratio 4.5 were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable is transverse steel ratio. Volumetric ratios of spirals of all the columns are 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The longitudinal steel ratio is 2.017%. The axial load ratio is 7%. This paper describes mainly crack behavior, load-displacement hysteresis loop, seismic performance such as equivalent damping ratio, residual displacement and effective stiffness and flexural over-strength of circular reinforced concrete bridge columns with respect to test variable. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications(Limited state design).

Analysis on Durability Performance of Spot Welding by the Status of Over-Slam Bumper in Hood System (후드 오버슬램범퍼 조립 상태에 따른 점용접의 내구성능 영향 분석)

  • Lee, Hyuk
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.273-279
    • /
    • 2017
  • Purpose: Recently, Issues on security for vehicles are getting increased all around the world. Especially, hood panel needs to be thinner for the protection of pedestrians. But thinner panel makes durability get worse. So, it is needed to satisfy both of them. Methods: Durability effectiveness will be studied because properties and assembly allowance of over-slam bumper mostly affects durability of hood panel. Overlap of over-slam bumper can be made in production line and it can affect durability of spot welding in hood inner panel. Daguchi method is used to catch the condition in which load gets smaller and location, hardness and quantity of overlap are selected to be factors. Durability effectiveness is analyzed with the factors. Result: the mechanism that affects on spot welding is identified. The test was conducted in both open/close and driving condition and the relation between both conditions is analyzed. Conclusion: The test contributed to durability of hood panel with optimization of over-slam bumper.

The Unary Feedback Over-Reporting Avoidance Scheme for the Event Report Management on the OSI Network Management System (OSI 망관리 시스템에서 사건복 관리를 위한 1진 피드백 과보고 회피기법)

  • 변옥환;진용옥
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.3
    • /
    • pp.1-15
    • /
    • 1993
  • In this paper, we propose over-reporting avoidance scheme which avoids congestion of network traffics by adjusting managed system's over-reporting, on the OSI network management model which reports events from managed system to managing system. In case of reporting events from managed system to managing system, management traffic concentration occurs, and it causes over-loading on the managing system and congestion on the network. This scheme takes advantage of feedback from managing system to managed system. Managed system transmits event reports as much as maximum event pertime allocated to itself to managing system, and it sets it's management variables to LOCK state and stops event reports as Threshold time is reached. At the time, managing system directs event reports again by using M-set primitive with referring it's status. With this scheme, distributed processing, dynamic network adaptation, convergence of optimal operation point is possible. In addition to it, a fairness is assured. In order to detect characteristics of the Unary feedback over-reporting avoidance scheme. It is observed a control capability of the event reporting and fairness of each nodes through measuring. ThresholdTime value. It is measured a number of mean activating nodes and maintained time of LOCK state according to event reporting load, and also measured lost ratio of management packet, queuing delay in managing system, and goodput to observe effects of general packet load. Binary feedback scheme. Unary feedback overreporting avoidance scheme and raw scheme on the OSI network management system each are compared and analyzed, and finally proved that the scheme proposed in this study performs better.

  • PDF

Evaluation of SWAT2000 Model Application for Estimating Delivered Nutrients Load for the Gap Stream Watershed (갑천유역의 영양염류 유달부하량 산정을 위한 SWAT2000 모형의 적용성 평가)

  • Moon, Jong-Pil;Kim, Tai-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.6
    • /
    • pp.89-100
    • /
    • 2006
  • In order to estimate delivered nutrients load from non-point sources in the Gap stream watershed in Daejeon, a distributed watershed model SWAT2000 was used so that it could predict the impact of land management practices on water, sediments and chemicals yields in large complex watersheds with varing soils, land uses and management condition over long period of time. The SWAT2000 was applied to the Daejeon (Indong), Yudeung (Boksu) and Gap (Hoeduck) streams for TMDL (Total Maximum Daily Load) of nutrients. The observed water quality and streamflow data of the year of 2002 and 2003 were used for calibration, and those of the year 2004 and 2005 were used for validation. Simulated results were evaluated by Estimation Efficiency Analysis (COE), Regression Analysis $(R^2)$ and Relative Error (R.E.) for the nutrients amounts on the monthly and yearly basis by comparing observed load with estimated load obtained by using SWAT2000 simulations. The COE value fur T-N was ranged from 0.59 to 0.78, $R^2$ values for T-N ranged from 0.65 to 0.84, and R.E values fur T-N load ranged from 4% to 20%. COE value far T-N was ranged from 0.59 to 0.73, $R^2$ values for T-P ranged from 0.67 to 0.82, and R.E values for T-P load ranged from 3% to 25%. Estimated results of SWAT2000 simulation for 3 sites (Indong, Boksu, Hoedeok) were reasonably satisfactory. This study indicated that SWAT2000 model could be applicable to estimate the nutrients load from the Gap stream watershed in Korea.

Study on the Characteristics of Consolidation(II) -The Effects of Load Increment Ratio Consolidation Characteristics- (압밀(壓密) 특성(特性)에 관(關)한 연구(硏究)(II) -하중(荷重) 증가율(增加率)이 압밀특성(壓密特性)에 미치는 영향(影響)-)

  • Kang, Yea-Mook;Ryu, Neung-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.4 no.1
    • /
    • pp.88-93
    • /
    • 1977
  • The following is the result of experiment on consolidation test under various load increment ratios by alternation of standard load increment ratio. The more load increment ratio was, the more settlement was resulted. But expansions were not associated with load increment ratios. Primary consolidation took longer period to complete as load increment ratio was decreased. And under the condition of over-consolidated range, the completion of primary consolidation took longer period as the load was incremented. Under the condition of normal consolidated range, there was no change in time of completing primary consolidation. The coefficient of consolidation was decreased with increment of consolidation load, and the coefficient of consolidation had high values as the load increment ratio was increased. The values of ratio of secondary consolidation was highest near the transition point of consolidation curve.

  • PDF

Load Frequency Control of Multi-area Power System using Auto-tuning Neuro-Fuzzy Controller (자기조정 뉴로-퍼지제어기를 이용한 다지역 전력시스템의 부하주파수 제어)

  • Jeong, Hyeong-Hwan;Kim, Sang-Hyo;Ju, Seok-Min;Heo, Dong-Ryeol;Lee, Gwon-Sun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.3
    • /
    • pp.95-106
    • /
    • 2000
  • The load frequency control of power system is one of important subjects in view of system operation and control. That is even though the rapid load disturbances were applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow one on each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation were given, the unstable phenomenal of power system can be often brought out because of the large frequency deviation and the unsuppressible power line one. Therefore, it is desirable to design the robust neuro-fuzzy controller which can stabilize effectively the given power system as soon as possible. In this paper the robust neuro-fuzzy controller was proposed and applied to control of load frequency over multi-area power system. The architecture and algorithm of a designed NFC(Neuro-Fuzzy Controller) were consist of fuzzy controller and neural network for auto tuning of fuzzy controller. The adaptively learned antecedent and consequent parameters of membership functions in fuzzy controller were acquired from the steepest gradient method for error-back propagation algorithm. The performances of the resultant NFC, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the load frequency control of multi-area power system, when the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbances of internal parameters and external stepwise load stepwise load changes, the superiorities of the proposed NFC in robustness and adaptive rapidity to the conventional controllers were proved.

  • PDF

Analysis of Discriminant Accuracy of Estimated Load Carrying Capacity in Bridges (교량 추정 내하율 판별 정확도 분석)

  • Kyu San Jung;Dong Woo Seo;Byeong Cheol Kim;Gun Soo Kim;Ki Tae Park;Woo Jong Kim
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.123-128
    • /
    • 2023
  • This paper presents the results of an analysis of the discrimination accuracy of a bridge load carrying capacity estimation model based on data from inspection reports. The load carrying rate estimation model was derived using statistical methods through the collection of 2,161 inspection reports. By entering the bridge specifications and maintenance information, you can check the estimated load carrying capacity of the bridge. In order to verify the discrimination accuracy of the estimated load carrying rate model, the estimated load carrying rate was compared with the load carrying rate in the inspection and diagnosis report for 164 public bridges for which data was available. Although there are differences depending on the bridge type, the results were obtained with an accuracy of over 80% in determining the estimated load carrying capacity.

Analysis of the Melting Characteristics of a Blade Type Fuse Used for Vehicles Due to Overload (과부하에 따른 차량용 블레이드형 퓨즈의 용단특성 해석)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.38-43
    • /
    • 2010
  • The purpose of this study is to secure the basis for judgment on the cause of an accident by analyzing the melting characteristics of a blade type fuse used for vehicles due to overload. In order to increase the reliability of the test, it was conducted by connecting the electrical system with conditions similar to those of an actual vehicle to apply the load. Carbonization pattern experiment of fuse by outside flame applied Korean Standard (KS). The fuse melted by the overcurrent showed a smooth cross-section while the test terminals, clear plastic body, etc., burnt out by the external flame was badly deformed. When 185% of the rated current (27.8A) was applied to a cable of 15A rated current onto which an over-capacity fuse (20A) was installed, the fuse melting time was 217 seconds. In addition, when a load current of 28.8[A] (139%) was applied, the fuse's test terminal and terminal blade were not burnt out although foam was observed on some parts of the plastic body. When a load capacity of 28.2[A] (141%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melting time was approximately 10 seconds. When a load current of 35.8[A] (119%) was applied, the fuse's test terminal and terminal blade were not burnt out, although some parts of the plastic body was swelled. However, it was observed that the switch terminal melted if approximately six minutes lapsed under such conditions. When a load capacity of 39.4[A] (131%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melted in approximately 69 seconds, and the test terminal and terminal blade were not burnt.