• Title/Summary/Keyword: Output unit

Search Result 968, Processing Time 0.029 seconds

Study on Expansion of Output Point for PLC Output Unit (PLC 출력 Unit의 출력 점수 확장에 관한 연구)

  • You Jeong-Bong;Jeon Ho-Ik;Nam Sang-Yep
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.25-32
    • /
    • 2005
  • PLC is the most widely utilized among many sorts of existing controller for the design of process control system, and study about a PLC language is performed actively. In this paper, we proposed the method that we increase an output points when increased of the output machine which is going to control it in the FA design that used PLC. Output point is going to be extended with 2-3 points in the state that cannot equip output unit in basic base any more. Then an extension base, a power supply, an extension cable and an output unit must be equipped particularly. Then a cost must be added very much. This paper propose the method which extended an output in a small quantity. We designed the expansion unit that received the points of output unit and decoded the signal and the program module that finally extended output points by encoding and decoding, and we confirmed his feasibility through a experiment.

The optimal operation condition of heat engine (熱機關의 最適 運轉條件)

  • 정평석;김수연
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.971-974
    • /
    • 1987
  • Considering heat transfer and heat loss processes for the heat engine operating between two fixed heat reservoirs, it may be qualitatively explained that the maxima of power output and its efficiency depending upon operating conditions are extreme maxima. Furthermore, it is also found that from an economic point of view the above two extremes are related to extreme minima of plant cost per unit power output and operation cost per unit power output respectively, and the condition of minimum cost per unit power output exists between the extreme minimum conditions of plant cost per unit power output and that of operation cost per unit power output.

Characteristics on the Output Coupled Type CVT Combined Differential Gear Unit (차동기어장치를 적용한 출력축 연결방식 무단변속기의 특성해석에 관한 연구)

  • Choi, Sang-Hoon;Kim, Yeon-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 2001
  • Continuously variable transmission(CVT) mechanisms considered here combine the functions of a 2K-H I type differential gear unit and a V-belt continuously variable unit(CVU). One shaft of the V-belt CVU is connected directly to the differential gear unit and remaining shaft of it is linked to the output shaft. These mechanisms have many advantage which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral. In this paper six different mechanisms of output coupled type CVT are proposed. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed, and theoretical analysis are proven by various experiments.

  • PDF

A Study on Measurement of Output Dose in X-ray Unit (X-선장치에서 출력선량 측정에 관한 연구)

  • Kim, Jong Eon;Lee, Sang Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.289-294
    • /
    • 2020
  • In order to control the quality of X-ray images and patient exposure, it is necessary to document the output dose(air absorption dose(mGy)) output from the X-ray unit from the measurement. The purpose of this study is to find an equation that can calculate the output dose from the measurement of the output dose and output factor(Of) of the X-ray Unit. The output dose and output factors of the X-beam irradiated from the X-ray unit were measured using an XR multi-detector. The output dose calculation formula was obtained by fitting the measured output dose divided by the tube current-exposure time product(mAs) and the set tube voltage with Allometric1. The final output dose calculation formula was obtained by multiplying this formula with the output factor. It is considered that the obtained final output dose calculation formula will be useful for all tube voltages, tube currents, exposure times, field sizes, and distances.

Financial Development and Output Growth: A Panel Study for Asian Countries

  • Jun, Sangjoon
    • East Asian Economic Review
    • /
    • v.16 no.1
    • /
    • pp.97-115
    • /
    • 2012
  • This paper investigates the relationship between financial markets and output growth for a panel of 27 Asian countries over 1960-2009. It utilizes the recently-developed panel cointegration techniques to test and estimate the long-run equilibrium relationship between real GDP and financial development proxies. Real GDP and financial development variables are found to have unit roots and to be cointegrated, based on various panel unit root tests and panel cointegration tests. We find that there is a statistically significant positive bi-directional cointegrating relationship between financial development and output growth by three distinct methods of panel cointegration estimation. Empirical findings suggest that financial market development promotes output growth and in turn output growth stimulates further financial development.

  • PDF

The optimum specifications and design of distributive transformers (배전용 변압기의 합리적인 사양과 그 설계법)

  • 이승원
    • 전기의세계
    • /
    • v.14 no.4
    • /
    • pp.8-17
    • /
    • 1965
  • Firstly, this study has analyzed the following factors affecting the optimum specifications and design of distributive transformers: 1. Facilities installation cost per unit power output. 2. Facilities operating & maintenance cost per unit power output. 3. Production cost per unit power output. 4. Load factor. 5. Loss factor. Secondly, it has clarified the relations between the following factors and the specifications and design of distributive transformers; 1. No-load loss., 2. Load loss., 3. Voltage regulation., 4. Exciting current. Finally, it has determined the method of the most economic design for the transformers using the above factors and relations, and, for optimum the illustrative purpose, suggested their optimum specifications, way of evaluation, and merits by means of typical example.

  • PDF

A Study on Wired LogiC for Type Unit for PLC Output Driving (PLC 출력 구동을 위한 Wired Logic for Type Unit에 관한 연구)

  • 위성동;김태성
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.51-57
    • /
    • 1999
  • This thesis is written about the Wired Logic Type Unit in developing equipment that the load is driven, that the interface unit connect with 1 Scan time to PO30 of operated PLC output contact with that a sensing signal of Temperature Sensor RSD Pt $100\Omega$ let generate the relay output of temperature controller and input the PLC. The PLC Test Kit in country that the PLC to be programmed at the PLC education place is able to drive the load, is done to do a education of PLC on status that interface process between PLC and load are disregarded. As Developing Kit for supplement this point, when the relay output of temperature controller to use Pt 100 of temperature sensor as mentioned on the former among every kinds of sensor feed back to the input of the PLC, as the equipment to act with real time system that the output contact of PLC operated to insert the WLTIJ among PC, PLC and the load, it can understand and see very easy the main principle of PLC use. The structure of WLTU to be a interface unit of load separated as to the point of contact and noncontact, sensor, indicating lamp and A contact and B contact that is belong to driving part, and a motor is belong to loading part.

  • PDF

A Study on the Digital Unit Development for Turbine Load Set Control (Turbine Load Set 조정을 위한 Digital Unit 개발)

  • Moon Yong-Seon;Jeong Ho-Jin;Kang Sung-Ryul;Choi Hyeong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.498-503
    • /
    • 2005
  • As important device that decide output load in superannuated thermoelectric power plant which do Turbine Load Set Motor device. This generation of electric power system operated Set Up Range Motor according to Set Up value that operator manufactures by hand circumvolve, and generation of electric power output load derision is consisted by internal action including Motor Therefore, in this research passively output load operated Turbine Motor Drive equipment that can have existing Turbine Load Set Motor Performance developing Digital Drive Unit device design. Also control algorithm implementation and existing Turbine Load Set Motor Drive and connection possibility through designed controlling system to connect basis function that decide development output load with Digital Drive Unit that designed also with existing Motor Drive Unit and can be operated.

Experimental and Parametric Study on the Output Coupled type Continuously Variable Transmission

  • Kim, Yeon-Su;Park, Jae-Min;Park, Sang-Hoon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.3
    • /
    • pp.28-36
    • /
    • 2002
  • The continuously variable transmission (CVT) mechanism considered here is the output coupled type which combines the functions of a 2K-H I type differential gear unit and a V-belt type continuously variable unit (CVU). One shaft of the CVU is connected directly to the output shaft and another shaft of it is linked to the differential gear unit. It is shown that some fundamental relations (speed ratios, power flows and efficiencies) for twelve mechanisms previously described are valid by various experimental studies, six of them produce a power circulation and the others produce a power split. Parametric analysis is carried out in relation to the efficiency, speed ratio and power ratios in order to assist in the design of an optimum configuration. Some useful properties associated with power flow modes also are discussed in the output coupled type continuously variable transmission.

Application of Input-Output Table to Estimate of Amount of Energy Consumption and CO2 Emission Intensity in the Construction Materials -Focusing on Input-Output Tables Published in 2005, 2007- (건축공사 주요자재별 에너지소비량 및 CO2 배출 원단위 값 산출에 산업연관표 적용 적정성 검토 연구 -2005년, 2007년 산업연관표를 중심으로-)

  • Jung, Young-Chul;Kim, Sung-Eun;Jang, Young-Jun;Kim, Tae-Hui;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.247-255
    • /
    • 2011
  • Currently, there is database for per unit requirements of major construction materials in terms of energy consumption and $CO_2$ emission based on the input-output table published by the Bank of Korea in 2000, but no database for per unit requirements based on input-output tables was published in 2005 and 2007. The purpose of this study was to calculate the unit requirement values of major construction materials in terms of energy consumption and $CO_2$ emission generated by using the input-output tables published in 2005 and 2007. To estimate the unit requirement values, a database building method with the input-output tables was adopted by selecting 16 types of construction materials in wide use on construction sites. When the study results were compared with existing unit requirement values based on the input-output table of 2000, there were small discrepancies, from which it can be interpreted that the method used in the study is reasonable. Unit requirement values estimated based on input-output tables of 2005 and 2007 tended to decrease, and the highest value of energy consumption and $CO_2$ emission were found in the materials using cement and rebar.