• Title/Summary/Keyword: Output response

Search Result 1,402, Processing Time 0.032 seconds

A DC droop control using an output current and a grid current for operating parallel-connected single-phase AC/DC converter (단상 AC/DC 컨버터의 병렬 운전을 위한 출력 전류와 계통 전류를 이용한 DC 드룹 제어)

  • Kim, Jung-Min;Kim, Bum-Jun;Lee, Kang-Joo;Kum, Ho-Jung;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.51-52
    • /
    • 2017
  • This paper presents an advanced DC droop using both an output current and a grid current. To control parallel-connected converters without communication, the DC droop control is conventionally used. The conventional DC droop control method droops output voltage using an output current. It cannot control the source current causing output voltage errors. This paper proposed the DC droop method using both an output current and a grid current to improve dynamic response of voltage droops. The simulation results with PSIM is provided.

  • PDF

Automatic cardiac output control algorithm for total artificial heart by current waveform analysis (전류파형분석에 의한 완전이식 인공심장의 심박출량 자동제어 알고리즘)

  • 최원우;김희찬;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.383-391
    • /
    • 1993
  • In this paper, a new automatic cardiac output control algorithm without any pressure sensors for the motor-driven electromechanical total artificial heart(TAH) was developed using motor current information. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control. But. such automatic control with sensors has some problems. To solve these problems, I proposed a new "sensorless" automatic cardiac output control algorithm providing the adequate cardiac output to the time-varying physiological demand without right atrial collapse. In-vitro tests were performed to evaluate the performance of a new algorithm and it satisfied the basic three requirements on the pump output response through the mock circulation tests.

  • PDF

Development of an Automatic Cardiac Output Control Algorithm for the Total Artificial Heart (완전 이식형 인공심장의 심박출량 자동 제어 알고리즘 개발에 관한 연구)

  • 최원우;김희찬;민병구
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.3
    • /
    • pp.38-47
    • /
    • 1995
  • A new automatic cardiac output control algorithm for the motor-driven electromechanical total artificial heart(TAH) was developed based on the motor current waveform analysis without using any extra transducer. The basic control requirements of artificial heart can be described in terms of three features : preload sensitivity, afterload insensitivity, and balanced ventricular outputs. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control, But such automatic control systems with sensors have had reliability problems. We proposed a new sensorless automatic cardiac output control algorithm providing adequate cardiac output to the time-varying physiological demand without causing right atrial collapse, which is one of the critical problem in an active-filling type device. In-vitro tests were performed on a mock circulation system to evaluate the performance of the developed algorithm and the results show that the new algorithm satisfied the basic control requirements on the cardiac output response and the possibility of application of the developed algorithm to in vivo experiments.

  • PDF

Dynamic-Response-Free SMPS Using a New High-Resolution DPWM Generator Based on Switched-Capacitor Delay Technique (Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 이용한 Dynamic-Response-Free SMPS)

  • Lim, Ji-Hoon;Park, Young-Kyun;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • In this paper, we suggest the dynamic-response-free SMPS using a new high-resolution DPWM generator based on switched-capacitor delay technique. In the proposed system, duty ratio of DPWM is controlled by voltage slope of an internal capacitor using switched-capacitor delay technique. In the proposed circuit, it is possible to track output voltage by controlling current of the internal capacitor of the DPWM generator through comparison between the feedback voltage and the reference voltage. Therefore the proposed circuit is not restricted by the dynamic-response characteristic which is a problem in the existing SMPS using the closed-loop control method. In addition, it has great advantage that ringing phenomenon due to overshoot/undershoot does not appear on output voltage. The proposed circuit can operate at switching frequencies of 1MHz~10MHz using internal operating frequency of 100 MHz. The maximum current of the core circuit is 2.7 mA and the total current of the entire circuit including output buffer is 15 mA at the switching frequency of 10 MHz. The proposed circuit has DPWM duty ratio resolution of 0.125 %. It can accommodate load current up to 1 A. The maximum ripple of output voltage is 8 mV. To verify operation of the proposed circuit, we carried out simulation with Dongbu Hitek BCD $0.35{\mu}m$ technology parameter.

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.

Cholinergic Control of Pancreatic Secretion: The Effects of Atropine on Plasma Cholecystokinin and Secretin Release

  • Jo, Yang-Hyeok;Rhie, Duck-Joo;Chang, Young-Soon;Hahn, Sang-June;Sim, Sang-Soo;Kim, Myung-Suk;Kim, Chung-Chin
    • The Korean Journal of Physiology
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 1991
  • Generally, it has been known that cholecystokinin (CCK) release into the plasma is under cholinergic control, but secretin release is not. Thus in anesthetized dogs we studied the effect of atropine $(50\;{\mu}g/kg\;followed\;by\;50\;{\mu}g/kg/hr)$ on pancreatic secretion and plasma concentrations of bioactive CCK and immunoreactive secretin in response to intraduodenal perfusion of sodium oleate (1, 3 and 9 mmol/hr). The volume, protein output and bicarbonate output of the secretion were increased by sodium cleats and this oleate-induced secretion was decreased significantly by atropine administration. However the increased plasma CCK and secretin levels by sodium oleate were not changed by atropine. These results indicate that atropine suppressed sodium oleate-induced pancreatic secretion through inhibiting cholinergic mechanism directly rather than decreasing the release of pancreatic secretory hormones. In another set of experiments, bilateral cervical vagi were stimulated electrically to observe the changes of pancreatic secretion and the above two plasma hormone levels in the presence or absence of atropine. In the vagally stimulated dogs, the volume, protein output and bicarbonate output of the pancreatic secretion were increased significantly. Both plasma secretin and CCK were concomitantly released significantly by vagal stimulation. Atropine significantly depressed the pancreatic secretory response as well as the release of these two pancreatic secretory hormones. Therefore, we conclude that in the presence of atropine the depressed pancreatic response to vagal stimulation is at least, in part, due to decreased release of endogenous CCK and secretin. In the vagally stimulated animals, however, the involvement of direct cholinergic influence on pancreatic exocrine gland remains to be answered.

  • PDF

Fast Simulation of Output Voltage for High-Shock Piezoresistive Microaccelerometer Using Mode Superposition Method and Least Square Method (모드중첩법 및 최소자승법을 통한 고충격 압저항 미소가속도계의 출력전압 해석)

  • Han, Jeong-Sam;Kwon, Ki-Beom
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.777-787
    • /
    • 2012
  • The transient analysis for the output voltage of a piezoresistive microaccelerometer takes a relatively high computation time because at least two iterations are required to calculate the piezoresistive-structural coupled response at each time step. In this study, the high computational cost for calculating the transient output voltage is considerably reduced by an approach integrating the mode superposition method and the least square method. In the approach, data on static displacement and output voltage calculated by piezoresistive-structural coupled simulation for three acceleration inputs are used to develop a quadratic regression model, relating the output voltage to the displacement at a certain observation point. The transient output voltage is then approximated by a regression model using the displacement response cheaply calculated by the mode superposition method. A high-impact microaccelerometer subject to several types of acceleration inputs such as 100,000 G shock, sine, step, and square pulses are adopted as a numerical example to represent the efficiency and accuracy of the suggested approach.

Reliability Design using Asymptotic Variance of Inverse Cumulative Distribution Function (분위수의 점근적 분산을 이용한 신뢰성 설계)

  • Cho H.J.;Baek S.H.;Hong S.H.;Cho S.S.;Joo W.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1682-1685
    • /
    • 2005
  • System algorithms estimated by deterministic input may occur the error between predicted and actual output. Especially, actual system can't predict the exact outputs due to uncertainty and tolerance of input parameters. A single output to a set of inputs has a limited value without the variation. Hence, we should consider various scatters caused by the load assessment, material characteristics, stress analysis and manufacturing methods in order to perform the robust design or estimate the reliability of structure. The system design with uncertainty should perform the probabilistic structural optimization with the statistical response and the reliability. This method calculated the probability distributions of the characteristics such as stress by combining stress analysis, response surface methodology and Monte-Carlo Method and got the probabilistic sensitivity. The sensitivity of structural response with respect to inconstant design variables was estimated by fracture probability. Therefore, this paper proposed the probabilistic reliability design method for fracture of uncorved freight end beam and the design criteria by fracture probability.

  • PDF

Internal Model Control of UPS Inverter with Robustness of Calculation Time Delay and Parameter Variation (연산지연시간과 파라미터 변동에 강인한 UPS 인버터의 내부모델제어)

  • Park, Jee-Ho;Keh, Joong-Eup;Kim, Dong-Wan;An, Young-Joo;Park, Han-Seok;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.175-185
    • /
    • 2002
  • In this paper, a new fully digital current control method of UPS inverter, which is based on an internal model control, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The internal model controller is adopted to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. That is, the average current of filter capacitor is been exactly equal to the reference current with a time lag of two sampling intervals. Therefore, this method has an essentially overshoot free reference-to-output response with a minimum possible rise time. The effectiveness of the proposed control system has been verified by the simulation and experimental respectively. From the simulation and experimental results, the proposed system is achieved the robust characteristics to the calculation time delay and parameter variation as well as very fast dynamic performance, thus it can be effectively applied to the power supply for the critical load.

Hybrid Current Mode Controller with Fast Response Characteristics for DC/DC Converter (빠른 응답특성을 갖는 DC/DC 컨버터 하이브리드 전류 모드 제어기)

  • Oh, Seung-Min;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.134-137
    • /
    • 2019
  • A wide-bandwidth current controller is required for fast charging/discharging of super capacitor applications. Peak current mode is generally used to accomplish fast charging/discharging because this mode has fast response characteristics. However, the peak current mode control must have a slope compensation function to restrain sub-harmonics oscillation. The slope must be changed accordingly if the controlled output voltage is varied. However, changing the slope for every changed output voltage is not easy. The other solution, selecting the slope as the maximum value, causes a slow response problem to occur. Therefore, we propose a hybrid mode controller that uses a peak current and a newly specified valley current. Through the proposed hybrid mode control, the sub-harmonic oscillation does not occur when the duty is larger than 0.5 because of the fast response.