• Title/Summary/Keyword: Output response

Search Result 1,402, Processing Time 0.03 seconds

A Study Compensation Method for Dynamic Characteristics in Electro-Hydraulic Servosystem Equipping Load Pressure Feedback Compensator (부하압력 피이드백 보상기를 장착한 전기-유압서보계의 동특성 개선에 관한 연구)

  • Kim, Jong-Kyum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.126-136
    • /
    • 1992
  • In this paper, a simple structured feedback compensation scheme for a electro-hydraulic servo system to keep the response characteristics unchanged regardless of the load variation is proposed. In electro-hydraulic servo system, servovalve is most important control element. But the relation between input corrent and output flowrate of the servovalve has properties as follows; firstly, in spite of constant input current, output flowrate decreases as load pressure increases, secondly, according to frequency response of typical servovalve, the characteristics of gain and phase shift is something like 2'nd order system. Load pressure feedback compensation method has been applied to eliminate the first influence, the second influence has been improved by phase lead compensation method. As a result of above compensation methods, regardless of variation load condition, spring and inertia load, the compensation scheme has been verified to be effective within the range of frequency less than 25Hz by static response and dynamic response in time domain and frequency domain through experiments.

  • PDF

Empirical modelling of chemically enhanced backwash during ultrafiltration process

  • Daramola, M.O.;Adeogun, A.G.
    • Membrane and Water Treatment
    • /
    • v.2 no.4
    • /
    • pp.225-237
    • /
    • 2011
  • In this study, response of reversibility of membrane flux during chemically enhanced backwash (CEB) to changes in filtration time, filtration flux and coagulant concentration dosing during ultrafiltration (UF) process was investigated using a regression model. The model was developed via empirical modelling approach using response surface methodology. In developing the model, statistically designed UF experiments were conducted and the results compared with the model output. The results showed that the performance of CEB, evaluated in terms of the reversibility of the membrane flux, depends strongly on the changes in coagulant concentration dosage and the filtration flux. Also the response of the reversibility of membrane flux during CEB is independent of the filtration time. The variance ratio, VR << $F_{value}$ and $R^2$ = 0.98 obtained from the cross-validation experiments indicate perfect agreement of the model output with experimental results and also testify to the validity and suitability of the model to predict reversibility of the membrane flux during CEB in UF operation.

A Novel Control Strategy for Input-Parallel-Output-Series Inverter System

  • Song, Chun-Wei;Zhao, Rong-Xiang;Lin, Wang-Qing;Zeng, Zheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.85-90
    • /
    • 2012
  • This paper presents a topology structure and control method for an input-parallel-output-series(IPOS) inverter system which is suitable for high input current, high output voltage, and high power applications. In order to ensure the normal operation of the IPOS inverter system, the control method should achieve input current sharing(ICS) and output voltage sharing(OVS) among constituent modules. Through the analysis in this paper, ICS is automatically achieved as long as OVS is controlled. The IPOS inverter system is controlled by a three-loop control system which is composed of an outer common-output voltage loop, inner current loops and voltage sharing loops. Simulation results show that this control strategy can achieve low total harmonic distortion(THD) in the system output voltage, fast dynamic response, and good output voltage sharing performance.

A Study on Output Multiplexer for Ka-Band Satellite Transponder (Ka 대역 위성 중계기용 출력 멀티플렉서에 관한 연구)

  • 이주섭;엄만석;박상준;이필용;염인복;박종흥
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.7
    • /
    • pp.706-712
    • /
    • 2004
  • This paper presents the design technique of output multiplexer(OMUX) for the Ka-band satellite transponder. Output multiplexer consists of low-pass filter(LPF), channel filter and manifold. Channel filters adopt dual-mode technique in design for mass and volume reduction and frequency response of channel filters is 4-pole elliptic response for high frequency selectivity. w-pass filters are designed to be of 13th order corrugated type for high rejection characteristic over reception band of satellite transponder. After initial design of channel filters and manifold, we optimized only a few design parameters for fast and easy optimization instead of optimizing all the design parameter. Measured results of a realized output umltiplexer for Ka-band satellite transponder show good agreement with the computed ones.

Optimal Current Detect MPPT Control of PV System for Robust with Environment Changing (환경변화에 강인한 태양광 발전의 최적전류 MPPT 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.47-58
    • /
    • 2011
  • This paper proposes the optimal current detect(OCD) maximum power point tracking(MPPT) control of photovoltaic(PV) system for robust with environment changing. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and temperature. Conventional MPPT control methods are tracked the maximum power point by constant incremental value. So these methods are slow the response speed and generated the vibration in steady state and cannot track the MPP in environment condition changing. And power loss is generated because of the self-excitation vibration in MPP region. To solve this problem, this paper proposes the novel control algorithm. Proposed algorithm is detected the optimal current in two control region using the output power and current curve. Detected current is used the converter switching for tracking the MPP. Proposed algorithm is compared output power error to conventional algorithm with radiation and temperature changing. In addition, the validity of the algorithm is proved through the output error response characteristics.

Feedforward Compensation Method of Output Voltage with 3Phase AC/DC PWM Converter on DC Distribution System for Improved Response (응답성 향상을 위한 직류배전용 3상 AC/DC PWM 컨버터 출력전압 전향보상 기법)

  • Choi, Hyeong-Jun;Lee, Chun-Bok;Hong, Seok-Jin;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.516-517
    • /
    • 2015
  • This paper proposes the feedforward compensation method of output voltage with 3phase AC/DC PWM converter on DC distribution system for improved response. AC/DC PWM converter on DC distribution is required power supply of high quality because of renewable energy sources and load links. In general, Feedforward compensation method of 3phase AC/DC PWM converter receives the sensor input to the output current, load power. Resulting, error of the sensing values and communication cause time delay. Therefore, Feedforward compensation method through only the output voltage is proposed in this paper. The feedforward compensation method through only the output voltage can be applied to the two-level AC/DC PWM converters, as well as multi-level converter or inverter.

  • PDF

Theoretical research on the identification method of bridge dynamic parameters using free decay response

  • Tan, Guo-Jin;Cheng, Yong-Chun;Liu, Han-Bing;Wang, Long-Lin
    • Structural Engineering and Mechanics
    • /
    • v.38 no.3
    • /
    • pp.349-359
    • /
    • 2011
  • Input excitation and output response of structure are needed in conventional modal analysis methods. However, input excitation is often difficult to be obtained in the dynamic load test of bridge structures. Therefore, what attracts engineers' attention is how to get dynamic parameters from the output response. In this paper, a structural experimental modal analysis method is introduced, which can be used to conveniently obtain dynamic parameters of the structure from the free decay response. With known damping coefficients, this analysis method can be used to identify the natural frequencies and the mode shapes of MDOF structures. Based on the modal analysis theory, the mathematical relationship of damping ratio and frequency is obtained. By using this mathematical relationship to improve the previous method, an improved experimental modal analysis method is proposed in this paper. This improved method can overcome the deficiencies of the previous method, which can not identify damping ratios and requires damping coefficients in advance. Additionally, this improved method can also identify the natural frequencies, mode shapes and damping ratios of the bridge only from the free decay response, and ensure the stability of identification process by using modern mathematical means. Finally, the feasibility and effectiveness of this method are demonstrated by a numerical example of a simply supported reinforced concrete beam.

A Study on Response Analysis by Transmission Error of Yaw Drive for 8 MW Large Capacity Wind Turbines (8 MW급 대용량 풍력발전기용 요 감속기 치합전달오차에 따른 응답해석에 관한 연구)

  • Seo-Won Jang;Se-Ho Park;Young-kuk Kim;Min-Woo Kim;Hyoung-Woo Lee
    • Journal of Wind Energy
    • /
    • v.15 no.1
    • /
    • pp.43-49
    • /
    • 2024
  • This study performed a response analysis according to the transmission error of the yaw drive. To perform the response analysis, the excitation source of the transmission error was modeled and the outer ring of the first stage bearing and the outer ring of the output shaft bearing were used as measurement positions. The response results were analyzed based on the vibration tolerance values of AGMA 6000-B96. As a result of the response of the first stage bearing outer ring, the maximum displacement of the first stage planetary gear system was 5.59 and the maximum displacement of the second to fourth stage planetary gear systems was 4.21 ㎛ , 3.13 ㎛ , and 25.6 ㎛ . In the case of the output shaft bearing outer ring, the maximum displacement of the first stage planetary gear system was 1.73 ㎛, and the maximum displacement of the second to fourth stage planetary gear system was 1.94 ㎛, 0.73 ㎛, and 2.03 ㎛. According to AGMA 6000-B96, the vibration tolerance of first stage is 17.5 ㎛, and the vibration tolerance of the second to fourth stages is 58 ㎛, 80 ㎛, and 375 ㎛, which shows that the vibration tolerance is satisfied and it is safe.

Analysis of the response of a distance relay for wind farm intertie protection (풍력발전단지 연계선 보호 거리계전기의 응동 특성 분석)

  • Kang, Yong-Cheol;Lee, Hye-Won;Zheng, Tai-Ying;Kang, Hae-Gweon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.484_485
    • /
    • 2009
  • Power output of a wind farm fluctuates throughout a day. This affect a distance relay for wind farm intertie protection because a voltage of a relaying point varies due to fluctuating output of a wind farm. This paper describes the analysis of the response of a distance relay for intertie protection when the power output of a wind farm increases. A series of single phase to ground faults were also simulated and analyzed with PSCAD/EMTDC generated data.

  • PDF

A study on the Parameter Regulation of PID Output Feedback Controllers (PID출력귀환 제어기의 변수조정에 관한 연구)

  • 성원기;최종수;하용수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.10 no.4
    • /
    • pp.184-192
    • /
    • 1985
  • The parameter regulation of proportional-plus-intergral-plus-derivative output feedback controllers is presented in the practical compter simulation and the time-domain analysis. Particularly, the restriction of parameter regulation for PID controller utilization is investigated as a result of simulation method. It is finally noted that one may resort to the design of controllers, as investigated, for rapid steady-state response, disturbance rejection, and transient response performance (over 3rd-order process) without computing the open-loop transfer functionmatrix. in consequence is presented the block diagram of sensor base system for PID output feedback controllers.

  • PDF