• 제목/요약/키워드: Output dose

검색결과 290건 처리시간 0.024초

육군자탕(六君子湯)이 위액(胃液) 분비(分泌) 및 적출(摘出) 위(胃) 운동(運動)에 미치는 영향(影響)에 관한 연구(硏究) (Effects of Yukgunja-Tang on Secretion of Gastric Juice and Movements of Isolated Stomach)

  • 장인규;박성일
    • 생약학회지
    • /
    • 제15권3호
    • /
    • pp.128-133
    • /
    • 1984
  • The extracts of Yukgunja-tang which has been used in some of gastroin testinal disorders were examined for secretion of gastric juice and movement of isolated stomach of rabbit. Experiments were performed with the dried extract of Yukgunja-tang (sample I) and the dried extract compound made of each drug of Yukgunja-tang (sample II). The secretion of gastric juice at the doses of 25.0 and 50.0mg/kg p.o. of sample I showed the decreases of 34.3 and 43.3%, respectively, as compared with control group, whereas the secretion at a dose of 76.8g/kg of sample II showed 43.1%. In gastric acid secretion, sample I showed 50.0% decrease at a dose of 50.0mg/kg and sample II showed 46.2% decrease at a dose of 76.8mg/kg. In pepsin output sample I showed 17.8 and 23.4% decreases at a dose of 25.0 and 50.0mg/kg, respectively, whereas sample II showed 22.5% decrease at a dose of 76.8mg/kg. The isolated stomach of rabbit showed dose-responsive contraction by addition of sample I, however the contraction was not observed by sample II.

  • PDF

CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가 (The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$)

  • 조한상;남상수;박혜진;김미화;박안태
    • 대한방사선치료학회지
    • /
    • 제23권1호
    • /
    • pp.51-58
    • /
    • 2011
  • 목 적: 본 연구에서는 본원에서 보유하고 있는 선형가속기 Clinac IX과 21EX (Varian, Palo Alto, CA)에 대하여 2008년부터 2010년까지 CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL)를 이용하여 측정한 일일 출력 값을 바탕으로 절대 선량에 대한 오차 범위를 평가함으로써 그 유용성을 확인하고자 하였다. 대상 및 방법: 일일 정도 관리는 Varian사의 21EX, IX 두 대의 선형가속기의 광자선(6 MV, 10 MV)을 대상으로 매일 치료시작 전 CHECKMATE$^{TM}$를 사용하여 측정되었고, 절대선량은 격주간격으로 물 팬텀을 이용하여 측정되었다. 21EX의 경우 2008년부터 2010년, IX는 2009년부터 2010년까지의 일일 정도 관리의 측정치와 절대선량 측정치의 데이터 값을 분석하였다. 각 데이터는 Excel 2007 (Microsoft, USA)을 이용하여 평균, 표준편차, 신뢰수준을 평가하였고, CHECKMATE$^{TM}$의 측정값과 절대선량의 유의성을 확인하기 위하여 각 데이터의 오차 값을 각각 비교 분석하였다. 결 과: 관찰 기간 동안 두 장비의 절대선량의 출력은 시간이 지남에 따라 점차 증가함을 보였고, 이 증가는 6 MV와 10 MV 두 에너지 모두에서 비슷한 양의 증가 추세를 보이고 있었다. 또한 CHECKMATE$^{TM}$의 측정치와 절대선량 값의 오차율은 모두 0.34 이하로 나타나 두 측정값이 서로 유의관계가 있음을 보였다. CHECKMATE$^{TM}$ 측정값이 상향됨을 확인 후 이를 조정하기 위하여 절대선량 측정하였고, 오차범위 2~3%에 근접한 경우 출력 값을 교정한 횟수는 21EX는 4회, IX는 3회였다. 결 론: CHECKMATE$^{TM}$를 이용하여 2년 동안 일일 출력 변화를 측정하고 분석한 결과, 품질 관리 시 준수해야 하는 출력 값이 허용 오차 범위 2~3% 내에서 절대선량의 측정값들과 유의성이 있음을 보였다. 따라서 선형가속기의 보다 효율적이며 신뢰도가 있는 일일 출력 검증을 위하여, CHECKMATE$^{TM}$의 사용을 고려할 수 있다. 또한 각 기관에서의 선형가속기 출력 값의 변화 추세를 파악하고 각 출력 값 교정에 참고할 수 있는 좋은 기준이 될 수 있다고 사료된다.

  • PDF

확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구 (A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy)

  • 이정우;김정만
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

수술중 전자선치료에 있어서 선량분포에 관한 연구 (A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.1-12
    • /
    • 1992
  • 전자선을 이용한 수술중 방사선치료를 위해서는 수술중에 드러내 놓은 종양에 고선량의 방사선을 조사하되 주변 정상 조직을 보존하기 위하여 cone 장치를 개발할 필요가 있으며, 임상에 필요한 자료를 얻는 것 뿐만아니라 콜리메이터에 의한 적정 X-선 창 크기도 정할 필요가 있다. holder와 cone으로 이루어진 알루미늄제 결합형 cone장치를 개발하였다. 광자선의 SSD 100cm에서 조사면 크기가 직경 4~9cm이면서 lcm씩 차이가 있는 28cm 길이의 원통형 cone을 만들였으며, holder는 cone의 직경이 7cm이상인 것과 미만인을 것을 접속시키기 위해 따로 두 개를 만들었다. holder의 측면에는 조사부위를 관찰하기 위한 거울과 조명등을 삽입할 수 있는 개구부를 두었다. cone에 의한 조사면 크기와 콜리메이터에 의한 X선 창의 크기의 여러 가지 결합에 대하여 수중의 전자선의 깊이선량분포독선 및 측방선량분포곡선, 선량분포를 1차원 물팬톰 장치로 조종하는 p-형 실리콘 검출기로 측정하였다. 출력계수도 p-형 실리콘 검출기로 수중에서 측정하였다. 전자선의 에너지와 cone의 크기의 결합이 일정할지라도 콜리메이터에 의한 X-선 창의 크기는 표면선량 및 최대신량점의 깊이, 80% 선량점의 깊이, 측방선량분포, 출력계수에 영향을 미쳤다. 그중, 출력계수의 변화가 가장 현저하였다. 예로서 9 MeV 전자선의 출력계수는 0.637과 1.549의 범위에 있었다. 콜리메이터에 의한 X-선 창의 크기는 수술중 전자선치료용 cone 장치의 벽으로 향하는 산란 전자의 양에 영향을 미치고, cone장치에서 다시 산란된 전자는 출력계수 뿐만 아니라 선량분포도 바꿀 것으로 생각된다. 따라서 수술중 전자선치료용 cone장치에 대한 선량분포 측정은 임상에서 선량의 불확정도를 최소화하기 위해 필수적이다.능적으로 평가되어야 하므로 앞으로 이에 대한 연구가 요구된다.수 있었다. 즉, $a^{*}$ / $b^{*}$ 의 비값이 1이상 흑은 1에 가까울 때는 미숙기, 0.8 부근 일때는 적숙기, 0.8보다 작아 질수록 적숙기에서 과숙기로 점차 옮아감을 알 수 있었다.지해줄 수 있는 문헌들이 충분히 고찰되지 못하였고, 이론적배경 또한 횡문화 이론과의 관련성이 적었다. 또한 횡 문화 연구에 기초가 되는 연구대상자의 사회 인구학적 특성과 역사적 배경은 잘 나타났으나, 이론적 연구와 경험적 연구 간에 괴리가 있었다. 3. 표본추출방법은 문화에 기반을 둔 대상자를 선정한다는 점에서 한계성 이 있었다. 4. 방법론적 이유로는 대상자와의 면담시간이 구체적으로 기술되지 않았으며, 고유한 언어를 통역하는 과정에서 의미론적 문제에 대한 고려가 부족하였다. 면접과 기록과정에서 보면 자료의 기록과정과 분류 및 분석과정이 명시되어 있지 않았다. 참여관찰과 면접방법을 사용시 이에 대한 자세한 기술이 되어 있지 않았다. 5. 연구결과의 적용 및 이에 대한 논의는 상당히 제한되어 있었는데, 수편의 연구만이 방법론 문제점과 앞으로의 연구분야에 대한 전망을 제시하였으며, 특이한 것은 어 떤 연구자도 이른 개발을 위한 적용 및 임상실무적 차원에서 간호에 대한 제언을 하지 않았다.유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard 알고리즘을 사용하였다. 서울 구로구 시흥동 산사태 발생 지역의 산사면에 대하여 개발된 모델을 적용하여 예제 해석을 수행함으로써, 지하수 흐름 모델이 산사태 발생 예측을 위하여 이용할 수 있음을 입증하였다. 또한, 매개변수분석 연구를 통하여, 변수 a값은 작은 변화에 대하여 목적함수값에 큰 변화를

  • PDF

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • 제44권3호
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.

고주파 공진형 인버터식 X-선 장치의 단시간 출력특성 비교 연구 (A Study on the Output Characteristics Comparison of High Frequency Resonant Inverter Type X-ray Generators in Short Exposure Time)

  • 정수복;이성길;임홍우;백형래
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 1999
  • 본 논문은 고주파 공진형 PWM 인버터식 X-선 장치의 인버터에 단상과 3상 전파정류방식 및 PSU 전원을 연결시켰을 때 나타나는 단시간 출력특성에 대해 분석하였다. X-선의 선질은 X-선관에 입력되는 DC 전압 파형에 의존한다. DC 출력전압 파형은 DC 전압전원의 고조파 왜곡에 의해 영향을 받는다. 이러한 관전압 파형의 왜곡은 X-선 출력의 직선성, 재현성 및 출력선질을 저하시킨다. 따라서 본 논문에서는 DC 출력전압 파형과 세 가지 형식의 DC 입력전원 형식에 따른 출력선량을 비교하였고 이에 따른 실험결과를 검토하였다.

디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가 (Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR))

  • 황준호;양형진;최지안;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제19권12호
    • /
    • pp.517-526
    • /
    • 2019
  • 본 연구는 자동노출제어장치 사용 시 파라미터 조합에 따른 영상 화질과 방사선 출력을 분석하여 임상에 적용할 수 있는 최적의 방법을 모색하고자 하였다. 실험방법은 관전압 70, 81 kVp와 자동노출제어장치(Automatic Exposure Control, AEC)의 감도 S200, S400, S800, S1000을 조합해서 복부와 골반부의 입사표면선량, 관전류량, 신호 대 잡음비(Signal to Noise Ratio, SNR), 대조도 대 잡음비(Contrast to Noise Ratio, CNR), 시간-방사선량 곡선을 구하였다. 그 후 영상 화질과 출력의 안정성을 평가하였다. 그 결과 입사표면선량, 관전류량, 신호 대 잡음비, 대조도 대 잡음비는 관전압과 감도가 높게 설정될수록 감소하였다. 또한 관전압과 감도가 높게 설정될수록 시간-방사선량 곡선은 출력의 안정성이 줄어드는 양상을 보였다. 결론적으로 복부와 골반부 검사 시 관전압과 감도를 높게 조합할수록 검출기는 영상 화질과 방사선 출력을 정상적으로 재현해내지 못하였다. 따라서 비교적 낮은 관전압과 감도를 조합하여 검출기가 파라미터의 조합을 인식할 때 발생하는 오차 범위를 최소화해야 영상 화질과 방사선 출력의 안정성을 최적화할 수 있다는 것을 알 수 있었다.

Clinical Comparison of Low-dose and High-dose Steroid in Pediatric Cardiac Surgery with Cardiopulmonary Bypass

  • Choi Seok-Cheol;Kim Song-Myung;Kim Yang-Weon
    • 대한의생명과학회지
    • /
    • 제12권3호
    • /
    • pp.289-301
    • /
    • 2006
  • Cardiopulmonary bypass (CPB) for cardiac surgery triggers the production and release of numerous chemotactic substances and cytokines, ensuing systemic inflammatory response that leads to postoperative major organ dysfunction. Traditionally, corticosteroids (steroid) have been administered to patients undergoing cardiac surgery to ward off these detrimental physiologic alterations. However, the majority of the studies have been performed on adult patients with high-dose steroid. We carried out a randomized, prospective, double-blind study to compare the efficacy of low-dose steroid with that of high-dose steroid and to determine the adequate dose of pretreated-steroid for prophylactic effects in pediatric cardiac surgery. Thirty pediatric patients scheduled for elective cardiac surgery were randomly assigned to two groups; fifteen patients received low-dose methylprednisolone (10mg/kg intravenously, n=15, low-dose group) and the others received high-dose methylprednisolone (30mg/kg intravenously, n=15, high-dose group) 1 hour prior to CPB. Arterial blood samples were taken before CPB (Pre-CPB), 10 minutes after start of CPB (CPB-10), and immediately after CPB-end (CPB-OFF) for measuring total leukocyte counts (T-WBC) and diff-counts, platelet counts, interleukin-6 (IL-6), myeloperoxidase (MPO), total antioxidant (TAO), neuron-specific enolase (NSE), troponin I (TNI), aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatinine, and blood urea nitrogen (BUN) levels. Other parameters such as volumes of urine output, pulmonary index $(PI,\;PaO_2/FiO_2)$, mechanical ventilating period, intensive care unit (ICU)-staying period, postoperative complications (fever, wound problem), postoperative 24 hrs and total volumes in blood loss, and hospitalized days were also assessed. All parameters were compared between two groups. There were no significant differences in T-WBC counts, monocyte fraction, platelet counts, TA levels, NSE levels, creatinine levels, BUN levels, the volumes of total urine output, PI, the incidences of fever and wound problem, postoperative 24hrs- and total-blood loss volumes and ICU-staying period between two groups (P>0.05). At CPB-OFF, neutrophil fraction, MPO level, TNI level, and AST level were higher in the high-dose group than in the low-dose group (P<0.05). IL-6 level at CPB-10 was higher in the high dose-group than in the low-dose group (P<0.05). Furthermore, mechanical ventilating periods and hospitalized days of the high-dose group were significantly longer than those of low-dose group (P<0.05). The high-dose group had significantly low lymphocyte fi-action at CPB-OFF compared with the low-dose group (P<0.001). These findings suggest that pretreatment of high-dose steroid is not superior to that of low-dose steroid regrading its potential benefits in pediatric cardiac surgery. Therefore, the conventional strategy of steroid treatment, high-dose pretreatment, should be modified in the cardiac surgery with CPB. However, further studies must be performed on the larger number of patients in as much as small number of patients in this study.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF