• Title/Summary/Keyword: Output current

Search Result 4,005, Processing Time 0.032 seconds

Excimer-Based White Phosphorescent OLEDs with High Efficiency

  • Yang, Xiaohui;Wang, Zixing;Madakuni, Sijesh;Li, Jian;Jabbour, Ghassan E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1520-1521
    • /
    • 2008
  • There are several ways to demonstrate white organic light emitting diodes (OLEDs) for displays and solid state lighting applications. Among these approaches are the stacked three primary or two complementary colors light-emitting layers, multiple-doped emissive layer, and excimer and exciplex emission [1-10]. We report on white phosphorescent excimer devices by using two light emitting materials based on platinum complexes. These devices showed a peak EQE of 15.7%, with an EQE of 14.5% (17 lm/W) at $500\;cd/m^2$, and a noticeable improvement in both the CIE coordinates (0.381, 0.401) and CRI (81). Devices with the structure ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 12% FPt (10 nm) /26 mCPy: 2% Pt-4 (15 nm)/BCP (40 nm)/CsF/Al [device 1], ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 2% Pt-4 (15 nm)/26 mCPy: 12% FPt (10 nm)/BCP (40 nm)/CsF/Al [device 2], and ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 2% Pt-4: 12% FPt (25 nm)/BCP (40 nm)/CsF/Al [device 3] were fabricated. In these cases, the emissive layer was either the double-layer of 26 mCPy:12% FPt and 15 nm 26 mCPy: 2% Pt-4, or the single layer of 26mCPy with simultaneous doping of Pt-4 and FPt. Device characterization indicates that the CIE coordinates/CRI of device 2 were (0.341, 0.394)/75, (0.295, 0.365)/70 at 5 V and 7 V, respectively. Significant change in EL spectra with the drive voltage was observed for device 2 indicating a shift in the carrier recombination zone, while relatively stable EL spectra was observed for device 1. This indicates a better charge trapping in Pt-4 doped layers [10]. On the other hand, device 3 having a single light-emitting layer (doped simultaneously) emitted a board spectrum combining emission from the Pt-4 monomer and FPt excimer. Moreover, excellent color stability independent of the drive voltage was observed in this case. The CIE coordinates/CRI at 4 V ($40\;cd/m^2$) and 7 V ($7100\;cd/m^2$) were (0.441, 0.421)/83 and (0.440, 0.427)/81, respectively. A balance in the EL spectra can be further obtained by lowering the doping ratio of FPt. In this regard, devices with FPt concentration of 8% (denoted as device 4) were fabricated and characterized. A shift in the CIE coordinates of device 4 from (0.441, 0.421) to (0.382, 0.401) was observed due to an increase in the emission intensity ratio of Pt-4 monomer to FPt excimer. It is worth noting that the CRI values remained above 80 for such device structure. Moreover, a noticeable stability in the EL spectra with respect to changing bias voltage was measured indicating a uniform region for exciton formation. A summary of device characteristics for all cases discussed above is shown in table 1. The forward light output in each case is approximately $500\;cd/m^2$. Other parameters listed are driving voltage (Bias), current density (J), external quantum efficiency (EQE), power efficiency (P.E.), luminous efficiency (cd/A), and CIE coordinates. To conclude, a highly efficient white phosphorescent excimer-based OLEDs made with two light-emitting platinum complexes and having a simple structure showed improved EL characteristics and color properties. The EQE of these devices at $500\;cd/m^2$ is 14.5% with a corresponding power efficiency of 17 lm/W, CIE coordinates of (0.382, 0.401), and CRI of 81.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

An Area-Efficient Time-Shared 10b DAC for AMOLED Column Driver IC Applications (AMOLED 컬럼 구동회로 응용을 위한 시분할 기법 기반의 면적 효율적인 10b DAC)

  • Kim, Won-Kang;An, Tai-Ji;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.87-97
    • /
    • 2016
  • This work proposes a time-shared 10b DAC based on a two-step resistor string to minimize the effective area of a DAC channel for driving each AMOLED display column. The proposed DAC shows a lower effective DAC area per unit column driver and a faster conversion speed than the conventional DACs by employing a time-shared DEMUX and a ROM-based two-step decoder of 6b and 4b in the first and second resistor string. In the second-stage 4b floating resistor string, a simple current source rather than a unity-gain buffer decreases the loading effect and chip area of a DAC channel and eliminates offset mismatch between channels caused by buffer amplifiers. The proposed 1-to-24 DEMUX enables a single DAC channel to drive 24 columns sequentially with a single-phase clock and a 5b binary counter. A 0.9pF sampling capacitor and a small-sized source follower in the input stage of each column-driving buffer amplifier decrease the effect due to channel charge injection and improve the output settling accuracy of the buffer amplifier while using the top-plate sampling scheme in the proposed DAC. The proposed DAC in a $0.18{\mu}m$ CMOS shows a signal settling time of 62.5ns during code transitions from '$000_{16}$' to '$3FF_{16}$'. The prototype DAC occupies a unit channel area of $0.058mm^2$ and an effective unit channel area of $0.002mm^2$ while consuming 6.08mW with analog and digital power supplies of 3.3V and 1.8V, respectively.

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

A Study on the Service Quality Improvement by Kano Model & Weighted Potential Customer Satisfaction Index (Kano 모델 및 가중 PCSI를 통한 서비스품질 개선에 관한 연구)

  • Kim, Sang-Cheol
    • Journal of Distribution Science
    • /
    • v.8 no.4
    • /
    • pp.17-23
    • /
    • 2010
  • The Banking industry is expanding rapidly. To keep the competitive advantages, participating companies concentrate their resource to provide the distinguishable services by increasing the service quality. This study is to find that how three kinds of service quality(process, output, and service environment) affect on the customer satisfaction. In this paper, WPCSI (Weighted Potential Customer Satisfaction Index) was developed using Kano model and PCSI. Kano's model of service quality classification was used to improve customer satisfaction, customer satisfaction index was calculated. Customer satisfaction index was calculated using the existing potential for improving customer satisfaction index (PCSI Index) to complement the limitations of the weighted potential improve customer satisfaction index (WPCSI) were used. Analysis using PCSI improve the quality of service levels may be useful in assessing. However, this figure is a marginal degree of importance on customers and quality characteristics have been overlooked but has its problems. A service provided to customers with some important differences depending on the interpretation of the scope for improvement is to be classified. In other words, the level of customer satisfaction and the satisfaction of the current difference between the comparison factor for the company to provide information about the priority of the improvement was not significant. Companies are also considered important that the customer does not consider the uniform quality of service provided can be fallible. In this study, the weighted potential to improve it improve customer satisfaction index (WPCSI) proposed a new customer satisfaction index. This is for customers to recognize the importance of quality characteristics by weighting factors, to identify practical and improved priority to provide more useful information than has been. Weighted potentially improve customer satisfaction index (WPCSI) presented in this study by the customers aware of the importance of considering the quality factor is an exponent. The results, 'Employees' working ability', 'provided the desired service level', 'staff to handle this task quickly enough' to the customer of the factors had significant effects on satisfaction are met. On the other hand 'aggressiveness on the product description of employees', 'service environment as a whole, beautiful enough to' meet and shows no significant difference between satisfaction. But 'aggressiveness on the product description of employees' and reverse (逆) were attributable to the quality. Small dogs and overly aggressive products that encourage the customer dissatisfaction that can result in widening should be careful because the quality factor can be said. As a result, WPCSI is more effect to find critical factors which can affect customer satisfaction than PCSI. After that, we discuss effects and advantages of customer satisfaction using WPCSI. This study, along with these positive aspects, the limitations are implied. First, this study directly to the bank so that I could visit any other way for customers, utilizing the Internet or mobile to take advantage of the respondents were excluded from the analysis. Second, in survey questionnaires can help improve understanding of the measures will be taken. In addition to the survey targeted mainly focused on Seoul, according to a sample, so sampling can cause problems is the viscosity revealed intends.

  • PDF

Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant (하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성)

  • Kim, Yong-Jun;Chung, David;Jeong, Mi-Jeong;Yoo, Hye-Young;Yoon, Cheol-Woo;Shin, Sun-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.23-33
    • /
    • 2016
  • The characteristics of ammonia generated from alkaline stabilization facilities was investigated which are for organic sewage sludge from wastewater treatment plants. The highest concentration of ammonia was found in mixing and curing process in alkaline stabilization facility and ammonia mainly showed a range of 87.78 ppm($66.62mg/m^3$) to 1,933 ppm($1,467.01mg/m^3$) by detection tube. This is presumed to occur because nitrogen oxides are converted into ammonia as the sewage sludge is mixed with lime. In some facilities, hydrogen sulfide and methyl mercaptan were detected in relatively high concentrations, but odor materials except ammonia were not detected in most of the facilities. The concentration of ammonia caused by process was generally high in the order of "mixing > curing > output > storage > drying > input." It was found that odor compounds are removed by wet absorption using sulfuric acid and sodium hypochlorite in the 5 alkaline stabilization facilities currently in operation. Each facility was designed to meet the concentration of after-treatment emission in 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) or 100 ppm($75.89mg/m^3$), but no facility satisfied the design standard for their emssion limit. In case of ammonia, some workplaces in alkaline stabilization facilities exceeded the exposure limits established by the Ministry of Labor. It appears that proper ventilation should be provided for the safety of workers in future. No odor compound including ammonia was found by detection tubes in the border of the facilities, but trace amounts of odor compounds are expected to exist, given the current operational status of facilities.

A Study on the Component-based GIS Development Methodology using UML (UML을 활용한 컴포넌트 기반의 GIS 개발방법론에 관한 연구)

  • Park, Tae-Og;Kim, Kye-Hyun
    • Journal of Korea Spatial Information System Society
    • /
    • v.3 no.2 s.6
    • /
    • pp.21-43
    • /
    • 2001
  • The environment to development information system including a GIS has been drastically changed in recent years in the perspectives of the complexity and diversity of the software, and the distributed processing and network computing, etc. This leads the paradigm of the software development to the CBD(Component Based Development) based object-oriented technology. As an effort to support these movements, OGC has released the abstract and implementation standards to enable approaching to the service for heterogeneous geographic information processing. It is also common trend in domestic field to develop the GIS application based on the component technology for municipal governments. Therefore, it is imperative to adopt the component technology considering current movements, yet related research works have not been made. This research is to propose a component-based GIS development methodology-ATOM(Advanced Technology Of Methodology)-and to verify its adoptability through the case study. ATOM can be used as a methodology to develop component itself and enterprise GIS supporting the whole procedure for the software development life cycle based on conventional reusable component. ATOM defines stepwise development process comprising activities and work units of each process. Also, it provides input and output, standardized items and specs for the documentation, detailed instructions for the easy understanding of the development methodology. The major characteristics of ATOM would be the component-based development methodology considering numerous features of the GIS domain to generate a component with a simple function, the smallest size, and the maximum reusability. The case study to validate the adoptability of the ATOM showed that it proves to be a efficient tool for generating a component providing relatively systematic and detailed guidelines for the component development. Therefore, ATOM would lead to the promotion of the quality and the productivity for developing application GIS software and eventually contribute to the automatic production of the GIS software, the our final goal.

  • PDF

A Design of PLL and Spread Spectrum Clock Generator for 2.7Gbps/1.62Gbps DisplayPort Transmitter (2.7Gbps/1.62Gbps DisplayPort 송신기용 PLL 및 확산대역 클록 발생기의 설계)

  • Kim, Young-Shin;Kim, Seong-Geun;Pu, Young-Gun;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.21-31
    • /
    • 2010
  • This paper presents a design of PLL and SSCG for reducing the EMI effect at the electronic machinery and tools for DisplayPort application. This system is composed of the essential element of PLL and Charge-Pump2 and Reference Clock Divider to implement the SSCG operation. In this paper, 270MHz/162MHz dual-mode PLL that can provide 10-phase and 1.35GHz/810MHz PLL that can reduce the jitter are designed for 2.7Gbps/162Gbps DisplayPort application. The jitter can be reduced drastically by combining 270MHz/162MHz PLL with 2-stage 5 to 1 serializer and 1.35GHz PLL with 2 to 1 serializer. This paper propose the frequency divider topology which can share the divider between modes and guarantee the 50% duty ratio. And, the output current mismatch can be reduced by using the proposed charge-pump topology. It is implemented using 0.13 um CMOS process and die areas of 270MHz/162MHz PLL and 1.35GHz/810MHz PLL are $650um\;{\times}\;500um$ and $600um\;{\times}\;500um$, respectively. The VCO tuning range of 270 MHz/162 MHz PLL is 330 MHz and the phase noise is -114 dBc/Hz at 1 MHz offset. The measured SSCG down spread amplitude is 0.5% and modulation frequency is 31kHz. The total power consumption is 48mW.

Estimation of Optimum Raate of Cattle Slurry Application for Forage Production Using Idled Rice Paddy I. The Effect of cattle slurry application on annual dry matter yield in reed canarygrass. (유휴 논토양에서 조사료 생산을 위한 적정 액상구비 시용수준의 추정 I. 액상구비의 시용이 Reed Canarygrass의 연 건물수량에 미치는 영향)

  • 이주삼;조익환;김성규;안종호
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.14 no.1
    • /
    • pp.50-56
    • /
    • 1994
  • This study was investigated for the purposes of securing forage resource using idled rice paddy recently increased in accordance to a current trend of farm products' liberalization and also of presevation of environment by using cattle sluny as liquid manure, which is seriously increasing these days. In this study, mean annual dry matter yield and its seasonal variation with reed canarygrass, and a optimum rate of cattle sluny application were investigated. The results are as follows: 1. According to the conditions of cutting frequencies(3, 4 and 5 cutting per year), mean annual dry matter yield was recorded from 8.9 tons to 10.9 tons per hectare and was the highest at 3 cutting frequency. 2. The use of cattle sluny with the levels of between 300 and 360 kg N per hectare showed a significantly higher mean annual dry matter yield than that of the control (non-fertilization). 3. The treatments with 3 and 4 cutting frequencies(90 kg Nhdyear, 120 kg Nhdyear) recorded higher dry matter yields than the control of the former level by 1.23 tons and 2.34 tons respectively and in the treatment of 5 cutting frequency, the second level with cattle sluny of 300 kg Nhdyear showed an increased dry matter yield of 2.11 tons compared to the former level(l50 kg Nhdyear). With regards to nitrogen efficiency, one kg of nitrogen is applied to 13.7, 19.4 and 14.1 kg of dry matter yields in the conditions of 3, 4 and 5 cutting frequencies respectively. 4. In view of seasonal variance of annual dry matter yield, the second cut in 3 cutting frequency, the third cut in 4 cutting frequency and the third in 5 cutting frequency showed the highest ratio as 42, 37 and 32% respectively compared to the total. 5. Under the conditions of this study, the 'Input-Output curve' from 5 cutting frequency was the closest to sigmaformed process(i=0.9993) of various cutting frequencies, and the maximum marginal yield in the treatment was obtained at the level of 250 kg Nha with cattle sluny. The economic level of cattle sluny was between 371.0 and 402.2 kg N and the highest dry matter yield was obtained at 489.3 kg Mdyear in the same treatment

  • PDF