• Title/Summary/Keyword: Output Ripple Current

Search Result 334, Processing Time 0.022 seconds

Interleaved ZVS Resonant Converter with a Parallel-Series Connection

  • Lin, Bor-Ren;Shen, Sin-Jhih
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.528-537
    • /
    • 2012
  • This paper presents an interleaved resonant converter with a parallel-series transformer connection in order to achieve ripple current reduction at the output capacitor, zero voltage turn-on for the active switches, zero current turn-off for the rectifier diodes, less voltage stress on the rectifier diodes, and less current stress on the transformer primary windings. The primary windings of the two transformers are connected in parallel in order to share the input current and to reduce the root-mean-square (rms) current on the primary windings. The secondary windings of the two transformers are connected in series in order to ensure that the transformer primary currents are balanced. A full-wave diode rectifier is used at the output side to clamp the voltage stress of the rectifier diode at the output voltage. Two circuit modules are operated with the interleaved PWM scheme so that the input and output ripple currents are reduced. Based on the resonant behavior, all of the active switches are turned on under zero voltage switching (ZVS), and the rectifier diodes are turned off under zero current switching (ZCS) if the operating switching frequency is less than the series resonant frequency. Finally, experiments with a 1kW prototype are described to verify the effectiveness of the proposed converter.

Non-isolated Bidirectional Soft-switching SEPIC/ZETA Converter with Reduced Ripple Currents

  • Song, Min-Sup;Son, Young-Dong;Lee, Kwang-Hyun
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.649-660
    • /
    • 2014
  • A novel non-isolated bidirectional soft-switching SEPIC/ZETA converter with reduced ripple currents is proposed and characterized in this study. Two auxiliary switches and an inductor are added to the original bidirectional SEPIC/ZETA components to form a new direct power delivery path between input and output. The proposed converter can be operated in the forward SEPIC and reverse ZETA modes with reduced ripple currents and increased voltage gains attributed to the optimized selection of duty ratios. All switches in the proposed converter can be operated at zero-current-switching turn-on and/or turn-off through soft current commutation. Therefore, the switching and conduction losses of the proposed converter are considerably reduced compared with those of conventional bidirectional SEPIC/ZETA converters. The operation principles and characteristics of the proposed converter are analyzed in detail and verified by the simulation and experimental results.

Power Factor Correction LED Driver with Small 120Hz Current Ripple (낮은 120Hz 출력 전류 리플을 갖는 역률개선 LED 구동 회로)

  • Sakong, Suk-Chin;Park, Hyun-Seo;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • Recently, the LED(Light Emitting Diode) is expected to replace conventional lamps including incandescent, halogen and fluorescent lamps for some general illumination application, due to some obvious features such as high luminous efficiency, safety, long life, environment-friendly characteristics and so on. To drive the LED, a single stage PFC(Power Factor Correction) flyback converter has been adopted to satisfy the isolation, PFC and low cost. The conventional flyback LED driver has the serious disadvantage of high 120Hz output current ripple caused by the PFC operation. To overcome this drawback, a new PFC flyback with low 120Hz output current ripple is proposed in this paper. It is composed of 2 power stages, the DCM(Discontinuous Conduction Mode) flyback converter for PFC and BCM(Boundary Conduction Mode) boost converter for tightly regulated LED current. Since the link capacitor is located in the secondary side, its voltage stress is small. Moreover, since the driver is composed of 2 power stages, small output filter and link capacitor can be used. Especially, since the flyback is operated at DCM, the PFC can be automatically obtained and thus, an additional PFC IC is not necessary. Therefore, only one control IC for BCM boost converter is required. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

Optimal Design of Notch Filter in Photovoltaic Inverter (태양광 인버터의 노치 필터 최적 설계)

  • Kim, Yong-Rae;Heo, Cheol-Young;Lee, Young-Kwoun;Choy, Ick;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.81-92
    • /
    • 2019
  • When Photovoltaic inverter is connected to grid and used as PVPCS (Photovoltaic Power Conditioning System), 120 Hz AC ripple occurs at the dc-link capacitor voltage. This AC ripple reduces the efficiency of PVPCS and shortens the lifetime of the capacitor. In this paper, we design a notch filter to remove AC ripple. As a result, the AC voltage ripple was removed from the dc link and the THD of the PVPCS output current with the notch filter was lowered. This notch filter is determined by the damping coefficient, the bandwidth coefficient, and the switching frequency. Among these, the switching frequency determines the switching loss and the size of the LC filter, and the PVPCS with the high switching frequency has a greater efficiency loss due to the switching loss than the efficiency improvement by the notch filter. Therefore, it is important to set the optimum switching frequency in the PVPCS with the notch filter applied. In this paper, THD and switching loss of PVPCS output current with notch filter are calculated through simulation, and cost function to calculate optimum switching frequency through data is proposed.

LCCT Z-Source DC-DC Converter with the Bipolar Output Voltages for Improving the Voltage Stress and Ripple (전압 스트레스와 맥동이 개선된 양극성 출력 전압을 갖는 LCCT Z-소스 DC-DC 컨버터)

  • Park, Jong-Ki;Shin, Yeon-Soo;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.91-102
    • /
    • 2013
  • This paper proposes the improved LCCT(Inductor-Capacitor-Capacitor-Trans) Z-source DC-DC converter (Improved LCCT ZSDC) which can generate the bipolar output voltages according to duty ratio D. The proposed converter has the characteristic and structure of Quasi Z-source DC-DC converter(Quasi ZSDC) and conventional LCCT Z-source DC-DC converter(LCCT ZSDC). To confirm the validity of the proposed method, PSIM simulation and a DSP based experiment were performed for each converter. In case which the input DC voltage is 70V, the bipolar output DC voltage of positive 90V and negative 50V could generate. Also, as comparison result of the capacitor voltage ripple in Z-network and the input current under the same condition for each converter, the voltage stress and the capacitor voltage in Z-network of the proposed method were lower compared with the conventional methods. Finally, the efficiency for each method was investigated according to load variation and duty ratio D.

Design and Control of the Phase Shift Full Bridge Converter for the On-board Battery Charger of Electric Forklifts

  • Kim, Tae-Hoon;Lee, Seung-Jun;Choi, Woo-Jin
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.113-119
    • /
    • 2012
  • This paper describes the design and control of a phase shift full bridge converter with a current doubler, which can be used for the on-board charger for the lead-acid battery of electric forklifts. Unlike the common resistance load, the battery has a large capacitance element and it absorbs the entire converter output ripple current, thereby shortening the battery life and degrading the system efficiency. In this paper a phase shift full bridge converter with a current doubler has been adopted to decrease the output ripple current and the transformer rating of the charger. The charge controller is designed by using the small signal model of the converter, taking into consideration the internal impedance of the battery. The stability and performance of the battery charger is then verified by constant current (CC) and constant voltage (CV) charge experiments using a lead-acid battery bank for an electric forklift.

Single-Phase Improved Auxiliary Resonant Snubber Inverter that Reduces the Auxiliary Current and THD

  • Zhang, Hailin;Kou, Baoquan;Zhang, He;Zhang, Lu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.1991-2004
    • /
    • 2016
  • An LC filter is required to reduce the output current ripple in the auxiliary resonant snubber inverter (ARSI) for high-performance applications. However, if the traditional control method is used in the ARSI with LC filter, then unnecessary current flows in the auxiliary circuit. In addressing this problem, a novel load-adaptive control that fully uses the filter inductor current ripple to realize the soft-switching of the main switches is proposed. Compared with the traditional control implemented in the ARSI with LC filter, the proposed control can reduce the required auxiliary current, contributing to higher efficiency and DC-link voltage utilization. In this study, the detailed circuit operation in the light load mode (LLM) and the heavy load mode (HLM) considering the inductor current ripple is described. The characteristics of the improved ARSI are expressed mathematically. A prototype with 200 kHz switching frequency, 80 V DC voltage, and 8 A maximum output current was developed to verify the effectiveness of the improved ARSI. The proposed ARSI was found to successfully operate in the LLM and HLM, achieving zero-voltage switching (ZVS) of the main switches and zero-current switching (ZCS) of the auxiliary switches from zero load to full load. The DC-link voltage utilization of the proposed control is 0.758, which is 0.022 higher than that of the traditional control. The peak efficiency is 91.75% at 8 A output current for the proposed control, higher than 89.73% for the traditional control. Meanwhile, the carrier harmonics is reduced from -44 dB to -66 dB through the addition of the LC filter.

Design of PFM Boost Converter with Dual Pulse Width Control (이중 펄스 폭을 적용한 PFM 부스트 변환기 설계)

  • Choi, Ji-San;Jo, Yong-Min;Lee, Tae-Heon;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1693-1698
    • /
    • 2015
  • This paper proposed a PFM(pulse-frequency modulator) boost converter which has dual pulse-width. The PFM boost converter is composed of BGR(band gap voltage reference generating circuit), voltage reference generating circuit, soft-start circuit, error amplifier, high-speed comparator, inductor current sensing circuit and pulse-width generator. Converter has different inductor peak current so it has wider load current range and smaller output voltage ripple. Proposed PFM boost converter generates 18V output voltage with input voltage of 3.7V and it has load current range of 0.1~300mA. Simulation results show 0.43% output voltage ripple at ligh load mode and 0.79% output voltage ripple at heavy load mode. Converter has efficiency 85% at light lode mode and it has maximum 86.4% at 20mA load current.

System of stable action waveform by pulse special quality of obstetrics and gynecology pulse style $CO_2$ laser (산부인과 펄스형 $CO_2$ 레이저의 펄스 특성에 의한 안정된 동작파형의 시스템)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.55-57
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular, tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

A New 120Hz DC Output Ripple-Voltage Suppression Scheme Using BIFRED Converter with Unity Power Factor (단위 역률을 갖는 BIFRED 컨버터를 이용한 새로운 120Hz DC 출력 리플-전압 저감 제어 기법)

  • Kim Jung-Bum;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.542-546
    • /
    • 2004
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still shows generally good performance such as low THD of input line current and high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and small size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.

  • PDF