• 제목/요약/키워드: Output Element

검색결과 820건 처리시간 0.032초

유니몰프 압전소자를 이용한 발전 판넬의 출력특성에 관한 연구 (A Study of Output Characteristics for the Generation Panel using Unimorph Piezoelectric Element)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.250-259
    • /
    • 2010
  • The ability for energy harvesting via the piezoelectric effect was studied for a unimorph element such as piezo buzzer. A simple equivalent circuit was proposed to predict the energy generated based on the internal stress. Unimorphs with a metal-cavity were used as a driving device of the generation panel. Both the AC open voltage and DC output voltage as a function of pressure period and number of element were measured. For the unimorph generation circuit, DC output voltage varies with pressure period, reaching a maximum value at $470{\mu}F$. The maximum output voltage a according to load resistance was measured at $1M{\Omega}$. Data analysis of the DC output voltage and time constant indicated that number of piezoelectric element of optimum was 60~80. It was found that piezoelectric unimorph has the possibility to be used as the driving element of the electric generation.

비이상적 마스크로 인한 하다마드변환 스펙트럼 검파기 출력값의 신호대 잡음비 감소의 해결방안 (Compensation for the decrease of output SNR of hadamard transform spectrometer with nonideal mask)

  • 남지탁;박진배;윤태성
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.4-7
    • /
    • 1997
  • When we use Hadamard transform spectrometers (HTS), we can increase signal to noise ratio(SNR) by multiplexing which is done by masks. But if the mask has a single defective element, output-SNR decreases. In this paper the effect of a single defective element on the output-SNR is investigated. And a method of compensating for the defective mask element is presented.

  • PDF

Identification of Backlash Nonlinear System by use of M-sequence and correlation

  • Kashiwagi, H.;Rong, Li.;Harada, H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.470-470
    • /
    • 2000
  • This paper describes a new method of identifcation of backlash nonlinear systems by use of M-sequence correlation method. In this method, we can obtain not only Volterra kernels of up to 3rd order of the nonlinear system, but also the width of the backlash element from observing the crosscorrelation between the input and the output. Here strictly speaking, a multi-valued nonlinear system such as backlash element can not be expressed by Volterra kernel representation mathematically. But in practice, we encounter many cases where it is difficult to treat them mathematically but they can be controlled from experience. So we here dare to suppose that backlash nonlinear system can be approximated by Volterra kernel representation. Simulations are carried out on a nonlinear system consisting of linear part plus backlash element. And Volterra kernels are measured. The output calculated from the observed Volterra kernels is in good agreement wi th the actual output. And we show that we can obtain the width of backlash element, which is one of the most important parameters, by observing the maximum value of crosscorrelation function between the input M-sequence and the output.

  • PDF

LVDT의 출력 특성에 미치는 공정 및 재료 변수의 영향에 관한 유한요소해석 (Finite Element Analysis of the Effects of Process and Material Parameters on the LVDT Output Characteristics)

  • 양영수;배강열
    • 한국기계가공학회지
    • /
    • 제20권9호
    • /
    • pp.11-19
    • /
    • 2021
  • Linear variable differential transformer (LVDT) is a displacement sensor and is commonly used owing to its wide measurement range, excellent linearity, high sensitivity, and precision. To improve the output characteristics of LVDT, a few studies have been conducted to analyze the output using a theoretical method or a finite element method. However, the material properties of the core and the electromagnetic force acting on the core were not considered in the previous studies. In this study, a finite element analysis model was proposed considering the characteristics of the LVDT composed of coils, core, magnetic shell and electric circuit, and the core displacement. Using the proposed model, changes in sensitivity and linear region of LVDT according to changes in process and material parameters were analyzed. The outputs of the LVDT model were compared with those of the theoretical analysis, and then, the proposed analysis model was validated. When the electrical conductivity of the core was high and the relative magnetic permeability was low, the decrease in sensitivity was large. Additionally, an increase in the frequency of the power led to further decrease in sensitivity. The electromagnetic force applied on the core increased as the voltage increased, the frequency decreased, and the core displacement increased.

직병렬 보상형 무정전 전원장치의 단일 스위치 직렬 요소 (A Single Switched Series Element of Series-Parallel Compensated UPS)

  • 이인우;박진형;전성즙
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.106-109
    • /
    • 1999
  • A single-switched series element for series-parallel compensated UPS is proposed. The proposed series element can handle only unidirectional power and the input voltage must be higher than the output voltage. But it is very useful when DC-link voltage is low and isolation transformer is need for output stage since only one active switch is used.

  • PDF

완전 결합형 ATM 스위치 구조 및 구현 (II부 스위치 엘리먼트 ASIC화 및 스위치 네트워크 구현에 대하여) (Structure and Implementation of Fully Interconnected ATM Switch (Part II : About the implementation of ASIC for Switching Element and Interconnected Network of Switch))

  • 김경수;김근배;박영호;김협종
    • 한국통신학회논문지
    • /
    • 제21권1호
    • /
    • pp.131-143
    • /
    • 1996
  • In this paper, we propose the improved structure of fully interconnected ATM Switch to develop the small sized switch element and represent practical implementation of switch network. As the part II of the full study about structure and implementation of fully interconnected ATM Switch, this paper especially describes the implementation of an ATM switching element with 8 input port and 8 output port at 155 Mbits/sec each. The single board switching element is used as a basic switching block in a small sized ATm switch for ATM LAN Hub and customer access node. This switch has dedicated bus in 12 bit width(8 bit data + 4 bit control signal) at each input and output port, bit addressing and cell filtering scheme. In this paper, we propose a practical switch architecture with fully interconnected buses to implement a small-sized switch and to provide multicast function withoutany difficulty. The design of switching element has become feasible using advanced CMOS technology and Embedded Gate Array technology. And, we also represent Application Specific Integrated Circuit(ASIC) of Switch Output Multiplexing Unit(SOMU) and 12 layered Printed Circuit Board for interconnection network of switch.

  • PDF

CDMA 기지국에 설치된 평면 스마트 안테나의 성능 고찰 (Performance of a Rectangular Smart Antenna in CDMA Basestation)

  • 홍영진
    • 한국통신학회논문지
    • /
    • 제32권3C호
    • /
    • pp.323-330
    • /
    • 2007
  • CDMA 셀룰라 망의 기지국에 이용될 수 있는 선형 스마트 안테나를 이차원으로 확장시켜 성능의 척도인 출력 신호대잡음비(Output SNR: Output Signal to Noise Ratio), 출력신호대간섭비(Output SIR: Output Signal to Interference Ratio), 출력신호대간섭잡음비(Output SINR: Output Signal to Interference plus Noise Ratio)를 도출 하였다 Beam forming algorithm 으로 SCGM(Simplified Conjugate Gradient Algorithm)을 설정하고 입력신호대 잡음비, antenna element 숫자, 간섭신호의 분포 등을 변화시키며 평면 스마트 안테나의 성능을 simulate 하였다. 간섭신호들의 방위각(Azimuth angle)이 -90도 에서 +90도 사이에서 고르게 분포할 때, 평면 스마트 안테나의 성능은 같은 숫자의 element를 갖는 선형 스마트 안테나의 성능에 근접함을 보였다.

Modal and structural identification of a R.C. arch bridge

  • Gentile, C.
    • Structural Engineering and Mechanics
    • /
    • 제22권1호
    • /
    • pp.53-70
    • /
    • 2006
  • The paper summarizes the dynamic-based assessment of a reinforced concrete arch bridge, dating back to the 50's. The outlined approach is based on ambient vibration testing, output-only modal identification and updating of the uncertain structural parameters of a finite element model. The Peak Picking and the Enhanced Frequency Domain Decomposition techniques were used to extract the modal parameters from ambient vibration data and a very good agreement in both identified frequencies and mode shapes has been found between the two techniques. In the theoretical study, vibration modes were determined using a 3D Finite Element model of the bridge and the information obtained from the field tests combined with a classic system identification technique provided a linear elastic updated model, accurately fitting the modal parameters of the bridge in its present condition. Hence, the use of output-only modal identification techniques and updating procedures provided a model that could be used to evaluate the overall safety of the tested bridge under the service loads.

ATM에 적합한 banyan 스위치 소자의 성능 개선에 관한 연구 (A study on performance improvement of switch element inbanyan network for ATM)

  • 조해성;김남희;이상태;정진태;전병실
    • 한국통신학회논문지
    • /
    • 제21권7호
    • /
    • pp.1756-1764
    • /
    • 1996
  • 본 눈문에서는 buffered Banyan 네트워크에 적용되는 스위치 소자의 성능을 향상시키는 방안을 제안하고 제안된 스위치 소자의 성능을 측정하여 성능이 향상됨을 보였다. 기존의 buffered Banyan 네트워크의 스위치 소자에 FIFO(First In First Out) 버퍼를 채용하므로서 HOL(Heda-Of-Line) 블로킹이 발생하여 네트워크의 성능을 저하시킨다. 제안된 스위치 소자는 기본정보 이외의 보조정보를 이용하여 버퍼를 관리하는 CASO(Contents ASsociated Output)버퍼를 채용하므로서 HOL(Head-Of-Line) 블로킹의 발생을 제거하여 네트워크의 성능을 향상시켰다. 또한 성능측정을 위하여 buffered Banyan 네트워크의 해석모델인 MY 모델에 근거하여 제안된 네트워크를 해석하였고 이 관계식들을 이용하여 성능을 측정하였다.

  • PDF

Energy harvesting using an aerodynamic blade element at resonant frequency with air excitation

  • Bolat, Fevzi C.;Sivrioglu, Selim
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.379-390
    • /
    • 2019
  • In this research, we propose an energy harvesting structure with a flexible blade element vibrating at its first mode to maximize the power output of the piezoelectric material. For this purpose, a piezoelectric patch was attached on the blade element used in a small-scale wind turbine, and air load was applied with a suitable angle of attack in the stall zone. The aerodynamic load created by air excitation vibrates the blade element in its first natural frequency and maximizes the voltage output of the piezoelectric patch. The variation of power outputs with respect to electrical resistance, air speed, and extra mass is experimentally investigated for various cases. An analytical model is constituted using a single-mode blade element with piezoelectric patch dynamics, and the power outputs of the obtained model are compared with experimental results.