• Title/Summary/Keyword: Output Area

Search Result 1,445, Processing Time 0.027 seconds

A Design of Transceiver for 13.56MHz RFID Reader using the Peak Detector with Automatic Reference Voltage Generator (자동 기준전압 생성 피크 검출기를 이용한 13.56 MHz RFID 리더기용 송수신기 설계)

  • Kim, Ju-Seong;Min, Kyung-Jik;Nam, Chul;Hurh, Djyoung;Lee, Kang-Yun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.3
    • /
    • pp.28-34
    • /
    • 2010
  • In this paper, the transceiver for RFID reader using 13.56MHz as a carrier frequency and meeting International Standard ISO 14443 type A, 14443 type B and 15693 is presented. The receiver is composed of envelope detector, VGA(Variable Gain Amplifier), filter, comparator to recovery the received signal. The proposed automatic reference voltage generator, positive peak detector, negative peak detector, and data slicer circuit can adjust the decision level of reference voltage over the received signal amplitudes. The transmitter is designed to drive high voltage and current to meet the 15693 specification. By using inductor loading circuit which can swing more than power supply and drive large current even under low impedance condition, it can control modulation rate from 30 percent to 5 percent, 100 perccnt and drive the output currents from 5 mA to 240 mA depending on standards. The 13.56 MHZ RFID reader is implemented in $0.18\;{\mu}m$ CM08 technology at 3.3V single supply. The chip area excluding pads is $1.5mm\;{\times}\;1.5mm$.

Floating Point Converter Design Supporting Double/Single Precision of IEEE754 (IEEE754 단정도 배정도를 지원하는 부동 소수점 변환기 설계)

  • Park, Sang-Su;Kim, Hyun-Pil;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.72-81
    • /
    • 2011
  • In this paper, we proposed and designed a novel floating point converter which supports single and double precisions of IEEE754 standard. The proposed convertor supports conversions between floating point number single/double precision and signed fixed point number(32bits/64bits) as well as conversions between signed integer(32bits/64bits) and floating point number single/double precision and conversions between floating point number single and double precisions. We defined a new internal format to convert various input types into one type so that overflow checking could be conducted easily according to range of output types. The internal format is similar to the extended format of floating point double precision defined in IEEE754 2008 standard. This standard specifies that minimum exponent bit-width of the extended format of floating point double precision is 15bits, but 11bits are enough to implement the proposed converting unit. Also, we optimized rounding stage of the convertor unit so that we could make it possible to operate rounding and represent correct negative numbers using an incrementer instead an adder. We designed single cycle data path and 5 cycles data path. After describing the HDL model for two data paths of the convertor, we synthesized them with TSMC 180nm technology library using Synopsys design compiler. Cell area of synthesis result occupies 12,886 gates(2 input NAND gate), and maximum operating frequency is 411MHz.

A CMOS 16:1 Binary-Tree Multiplexer applying Delay Compensation Techniques (딜레이 보상 기법을 적용한 바이너리-트리 구조의 CMOS 16:1 멀티플렉서)

  • Shon, Kwan-Su;Kim, Gil-Su;Kim, Kyu-Young;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.21-27
    • /
    • 2008
  • This paper describes a CMOS 16:1 binary-tree multiplexer(MUX) using $0.18-{\mu}m$ technology. To provide immunity for wide frequency range and process-and-temperature variations, the MUX adopts several delay compensation techniques. Simulation results show that the proposed MUX maintains the setup margins and hold margins close to the optimal value, i.e., 0.5UI, in wide frequency-range and in wide process-and-temperature variations, with standard deviation of 0.05UI approximately. These results represent that these proposed delay compensations are effective and the reliability is much improved although CMOS logic circuits are sensitive to those variations. The MUX is fabricated using $0.18-{\mu}m$ CMOS process, and tested with a test board. At power supply voltage of 1.8-V, maximum data-rate and area of the MUX is 1.65-Gb/s and 0.858 $mm^2$, respectively. The MUX dissipates a power of 24.12 mW, and output eye opening is 272.53 mV, 266.55 ps at 1.65-Gb/s operation.

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

365 nm LED laser treatment on beagle for gingival whitening without gum dermabrasion (잇몸 박피술 없는 치은 미백을 위한 비글에서 365 nm LED 레이저 치료)

  • Lee, Sung-Ho;Kim, Ryun Kyung;Seo, Na-Ri;Lim, Ho-Kyung;Byun, Soo-Hwan;Lim, Young-Joon;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.117-122
    • /
    • 2016
  • Purpose: Gingival whitening is one of dental treatment purposes which is close to treating aesthetic disorders. Initial gingival whitening treatment was done by dermabrasion using a high power Diode Laser. However, this treatment method cannot be free from any infection or pain after the treatment. Therefore, we have decided to progress gingival whitening treatment using a low power LED laser. Materials and Methods: The laser was irradiated on pork meat then the safety of output power, temperature change and skin denaturalization was measured. Bison 365 nm LED laser was irradiated on oral mucosal pigment of a 15 - 20 kg beagle for 15 min for 1 - 2 weeks, one or two times each. Any pigment loss was checked through Hematoxyline-Eosin staining. Results: The melanin pigments at the area of 365 nm LED Laser irradiation were decreased. Conclusion: The 365 nm LED Laser proposed in this study is considered to compensate the bleaching effect achieved by either using Diode laser or surgical methods.

Application and Development of 'Chestnut Management Standard Diagnostic Table' (밤나무 경영 표준진단표의 개발 및 적용)

  • Jeon, Jun-Heon;Yoo, Byoung-Il;Lee, Jung-Min;Ji, Dong-Hyun;Kim, Yeon-Tae;Kang, Kil-Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.4
    • /
    • pp.695-702
    • /
    • 2012
  • The chestnut management standard diagnostic table is developed and would be utilized in order that a manager raising chestnuts checks where the own level of management is and grasps current state of own for the purpose of planning aims and advancing toward a higher level. The developed 'Chestnut management standard diagnostic table' consisted of 3 first classified items, 19 second classified items and 2 product indicator items by the chestnut experts consultative meeting. A survey of 212 farmhouses in 4 major producing area was conducted. Except invalid survey of 53 farmers, 159 farmhouses interviewed were used in analysis. Total score was calculated with sum of each item's score. According to the survey results, average score is 68.0 and Buyeo received the highest score of 69.7 and Suncheon received the lowest score of 61.8 by regional groups. The higher the group in score, the better it is in output per hectare. But the property of 'the ratio of the best products in total products' does not show a statistical correlation. Generally the score of 'management-based evaluation indicator part' and 'management and sale capacity indicator part' in Suncheon was low because of many elderly people. In part of 'manufacturing technology indicator' as Environmentally-Friendly production is progressed in over 70% of four regions, when comes to a disease and insect pest control there are rarely farmhouses having a way of crop dusting.

Tethering Meat Goats Grazing Forage of High Nutritive Value and Low to Moderate Mass

  • Patra, A.K.;Puchala, R.;Detweiler, G.;Dawson, L.J.;Animut, G.;Sahlu, T.;Goetsch, A.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.9
    • /
    • pp.1252-1261
    • /
    • 2008
  • Twenty-four yearling Boer$\times$Spanish goats were used in a crossover design experiment to determine effects of tethering on forage selection, intake and digestibility, grazing behavior and energy expenditure (EE) with forage high in nutritive value and low to moderate in mass. Objectives were to determine if tethered goats could be used as a model for study of unrestrained animals and to characterize tethering as a production practice. Four 0.72-ha pastures of wheat (Triticum aestivum) and berseem clover (Trifolium alexandrium) were grazed in December and January. Each pasture hosted six animals, three with free movement and three attached to a 4.11-m tether for access to a circular area of $53.1m^2$. Tethering areas were moved each day. One animal of each treatment and pasture was used to determine forage selection, fecal output or grazing behavior and EE; therefore, there were eight observations per treatment. Mass of forage DM before grazing in Tethered areas averaged 1,280 and 1,130 kg/ha in periods 1 and 2, respectively. The CP concentration in ingesta was greater ((p<0.05) 239 and 209 g/kg; SE = 8.0) and the NDF level was lower (p<0.05) for Free vs. Tethered animals (503 and 538 g/kg; SE = 12.0); in vitro true DM digestion was similar between treatments (0.808 and 0.807 for Free and Tethered, respectively; SE = 0.0096). Intakes of DM (1,013 and 968 g/d; SE = 78.6), NDF (511 and 521 g/d; SE = 39.9) and ME (10.9 and 10.7 MJ/d; SE = 0.90) were similar between treatments, but CP intake was greater (p<0.05) for Free vs. Tethered animals (241 and 203 g/d; SE = 17.2). There were small treatment differences in in vivo apparent digestibility of OM ((p<0.05) 0.780 and 0.814; SE = 0.0049), CP ((p<0.05) 0.800 and 0.817; SE = 0.0067) and NDF ((p<0.09) 0.777 and 0.760 for Free and Tethered, respectively; SE = 0.0078). There were no treatment effects on time spent ruminating or grazing (346 and 347 min/d for Free and Tethered, respectively; SE = 42.5), but EE was considerably greater (p<0.05) for Free vs. Tethered animals (571 and 489 kJ/kg $BW^{0.75}$; SE = 8.9). In conclusion, with forage of high nutritive value and low to moderate in mass, tethering can offer a production advantage over free grazing of less energy used for activity despite similar grazing time. With forage removal considerably less than that available for grazing, effects of tethering on chemical composition of selected forage were small and less than needed to markedly affect digestion. Tethering may offer a means of studying some aspects of grazing by ruminants, but would not seem suitable for energy metabolism.

VRIFA: A Prediction and Nonlinear SVM Visualization Tool using LRBF kernel and Nomogram (VRIFA: LRBF 커널과 Nomogram을 이용한 예측 및 비선형 SVM 시각화도구)

  • Kim, Sung-Chul;Yu, Hwan-Jo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.5
    • /
    • pp.722-729
    • /
    • 2010
  • Prediction problems are widely used in medical domains. For example, computer aided diagnosis or prognosis is a key component in a CDSS (Clinical Decision Support System). SVMs with nonlinear kernels like RBF kernels, have shown superior accuracy in prediction problems. However, they are not preferred by physicians for medical prediction problems because nonlinear SVMs are difficult to visualize, thus it is hard to provide intuitive interpretation of prediction results to physicians. Nomogram was proposed to visualize SVM classification models. However, it cannot visualize nonlinear SVM models. Localized Radial Basis Function (LRBF) was proposed which shows comparable accuracy as the RBF kernel while the LRBF kernel is easier to interpret since it can be linearly decomposed. This paper presents a new tool named VRIFA, which integrates the nomogram and LRBF kernel to provide users with an interactive visualization of nonlinear SVM models, VRIFA visualizes the internal structure of nonlinear SVM models showing the effect of each feature, the magnitude of the effect, and the change at the prediction output. VRIFA also performs nomogram-based feature selection while training a model in order to remove noise or redundant features and improve the prediction accuracy. The area under the ROC curve (AUC) can be used to evaluate the prediction result when the data set is highly imbalanced. The tool can be used by biomedical researchers for computer-aided diagnosis and risk factor analysis for diseases.

A Comparative Analysis of Terminal Efficiency in Northeast Asia Container Ports (동북아시아 주요 컨테이너항만의 효율성 비교연구)

  • Li, Duo;Kwak, Kyu-Seok;Nam, Ki-Chan;An, Young-Mo
    • Journal of Navigation and Port Research
    • /
    • v.39 no.1
    • /
    • pp.55-60
    • /
    • 2015
  • The purpose of this study is to suggest a major strategy to become effective for each port in Northeast Asia by analyzing the relative efficiency of each port to determine the current level of efficiency, efficient harbors plan. Individual port of the major 16 ports in Northeast Asia was analysed targeting efficiency and relative efficiency. In this study, DEA technique was used. Of the DEA model, CCR (constant returns to scale) models and BCC (variable return to scale) model was applied to analyze the efficiency and effectiveness of the port. Then the efficiency measured through CCR model is again compared with the efficiency measured by the BCC model. In this way, the empirical analysis includes the input factors of the operating ports such as the number of berths, wharf, depth, total area of the pier, C / C numbers and output elements includes the container throughput. The results of the study show that most of the ports in China is efficient whereas those in Korea and Japan are relatively inefficient. There are some pairs of ports which has the similar input factors, like Busan port and Shanghai port, Lianyungang port and Incheon port, Dalian port and Gwangyang port, but the container throughput of them has a huge difference.

Efficiency Analysis of Jeollanam-do Food Exprt Industry using DEA and Tier Models (DEA 모형과 Tier 분석을 이용한 전라남도 식품수출업체의 효율성 분석)

  • Chang, Seog-Ju
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.2
    • /
    • pp.125-136
    • /
    • 2017
  • This study focuses on a relative efficiency of 109 operating food companies out of 22 regions in Jeollanam-do. The relative efficiency has been analyzed by 5 input factors(capital, number of employees, annual labor costs, raw material purchase, and site area) and 2 output factors(annual exports and annual production of the companies in Jeollanam-do). This study suggests efficient companies which inefficient companies can benchmark to improve their system in short-mid-long term in phases. The main result of empirical analysis are as follows: Firstly, according to the Traditioanl DEA analysis, 7 companies out of 109 DMU indicate the optimal production scale in score 1 of CCR efficiency value, BCC efficiency value, and scale efficiency value. Secondly, a result from the Tier 1 step of inefficient companies by Post-DEA suggests that it would be better to apply each Tier step to the proper stage of the worst 5 inefficient companies such as Tier 3 step(short-term benchmark)${\rightarrow}$Tier 2 step(mid-term benchmark)${\rightarrow}$Tier 1 step(long-term benchmark) in step. This study expects that the result of the study can reduce the trial and error in inefficient part, lead to improvement, and have a big help in food exporting industry in the end.

  • PDF