• Title/Summary/Keyword: Outlet port

Search Result 53, Processing Time 0.025 seconds

Hydraulic Characteristics of the Non-power Soil Cleaning and Keeping System by the Large-Scale Model Test at the Dike Gate (배수문에서 실내모형실험에 의한 무동력 토사제거시스템의 수리 특성)

  • Park, Chan Keun;Oh, Beom Hwan;Lee, Dal Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.67-75
    • /
    • 2014
  • In this study, the large-scale hydraulic model test was performed to investigate the hydraulic characteristics for development of the non-power soil cleaning and keeping system at the dike gate. The outlet height, outflow number, outflow discharge, and outflow cycle were compared and analyzed. The non-power soil cleaning and keeping system was most effective at 11.2 mm in the outlet height. And then the mean outflow cycle was 1.09 sec, and the mean outflow discharge was $0.00164m^3/s$. The total outflow number increased gradually as the water level of a water tank increased, and the outlet height decreased. As a level of water tank decreased, the mean outflow cycle was lengthened, and the unit outflow discharge increased. This result showed this system was most effective. To remove the silty clay deposited in facilities, the methods of excavation, dredging, high pressure washing, etc have been applied to the tidal facilities such as land reclamation, a small size fishing port, and a harbor for maintenance. However, this is extremely cost-ineffective, whereas the non-power soil cleaning and keeping system will bring about an enormously positive economic effect. In addition, when the non-power soil cleaning and keeping system is applied to the dike gate of land reclamation, a thorough examination of the local tidal data and the careful system planning are required to prevent the disaster damage caused by flooding.

A Study on Flow and Mixing Caracteristics according to Hot Water Extraction (온수 추출에 따른 유동 및 혼합 특성에 관한 연구)

  • 장영근;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.53-59
    • /
    • 1995
  • In a hot water extraction process, the flow pattern of upper region in a storage tank is a major reason of mixing between hot water and cold water. In this study, the temperature distribution in a storage tank was measured to predict the flow pattern of upper region, and the degree of stratification was analysed to the variables dominating a extraction process. And also, it was found that the degree of stratification improved expecially in a low flow rate in case of using modified distributor I(DMI) as a outlet port type.

  • PDF

The Development of Screw Type Supercharger on CNG-Fueled Engine for Heavy Duty Vehicle (대형 CNG 엔진용 스크류형 과급기 개발에 관한 연구)

  • Kang, W.;Park, D.K.;Kim, H.C.;Oh, P.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.195-201
    • /
    • 1998
  • This study aims at the optimal design of rotors and the development of screw type Supercharger of CNG-fueled engine for commercial vehicle. Based on the new rotor profile, an advanced oil free type Supercharger has been developed, which can achieve higher adiabatic efficiency and lower manufacturing cost. The performance test of screw type Supercharger has achieved high volumetric efficiency and the durability on the bench of performance test has also been established in the compact body.

  • PDF

NEAR-FIELD DILUTION OF ROSETTE TYPE MULTIPORT WASTEWATER DIFFUSERS

  • Seo, Il-Won;Yeo, Hong-Koo
    • Water Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.93-111
    • /
    • 2002
  • In this paper, mixing characteristics and dilution of the merging buoyant discharges from array of multiple jets has been extensively studied in the hydraulic model experiments. New equations for dilution, which include the merging effects correctly, were derived. Experiments were constructed in a 20-m long, 4.9-m wide and 0.6-m deep flume, and the model diffuser was manufactured to indicate the typical characteristics of the existing ocean wastewater outfall in South Korea. Buoyant discharge from the diffuser was reproduced using heated water. Water temperature was measured using CC-Type thermocouple sensors, which were connected to a 40-channel data logger. Experimental results show that merging between ports in a particular riser is dependent upon the discharge densimetric Froude number, whereas merging between two ports which are facing each other at 90$\circ$ at the adjacent risers is dependent upon the discharge densimetric Froude number and distance from the port and port spacing. Centerline dilution increase with distance from the port outlet until two plumes has merged. However, after merging occurs, increase of the centerline dilution almost stops. Further distance from the position where merging occurs, centerline dilution increases again.

  • PDF

Analysis of Air Circulation in Oyster Mushroom Farm

  • Jeong, Won-Geun;Lim, Hack-Kyu;Kim, Tae-Han
    • Journal of Biosystems Engineering
    • /
    • v.37 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • Oyster mushroom farm which could not meet optimum temperature range yields non-uniform sized, low quality products. Thus, this study, utilizing STAR CCM+, one of the computational fluid dynamics (CFD) programs, analyzed the impact of air circulation and temperature distribution. Methods: After we visited numerous mushroom farms, we measured the temperature at the discharge ports of heaters, fan capacity, and the locations of the air circulators in the farms. According to the data, most mushroom growers installed the heaters near the entrance and discharge ports of the heaters at the third growing bed on the same height as the heaters in the entrance. The temperature at the discharge port of heater was $1,26^{\circ}C$, and the fan capacity was 4,500 $m^3$/hr. The air circulator was placed in the center of the mushroom farm 50cm above the ground, and its capacity of inlet port was 1,100 $m^3$/hr and discharge port 1,600 $m^3$/hr. The mushroom farm was insulated. Results: According to the analysis of the temperature distribution in the vertical plane of the entrance side, no air circulation causes the high temperature zone of 296~299K at the discharge port of the heater to take up 34% of area while the operation of air circulators causes it to occupy only 9%. This means that not using air circulators leads to a concentration of high temperature at the discharge port near the entrance. In addition, with the results of the analysis of the temperature distribution in the vertical planes of the center, no air circulation causes the temperature zone of 295~298K at the discharge port of the heater to take up 48% of area while the operation of air circulators causes it to occupy 80%. This shows that the high outlet port temperature disseminated to the center. Conclusions: After ninety minute operation of both heater and air circulator, the interior temperature became stabilized in the mushroom farm. Air circulation made the high temperature at the discharge port disseminate to the center and exit in the farm and equalize the temperature distribution.

Performance Improvement of Peristaltic Micropump Using Various Actuating Signal (다양한 동작신호의 사용에 따른 연동형 마이크로 펌프의 성능 향상)

  • Hong, Pyo-Hwan;Jung, Dong-Geon;Pyo, Dae-Seong;Lee, Jong-Hyun;Cho, Chan-Seob;Kim, Bonghwan
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.428-432
    • /
    • 2013
  • This paper described the development of electrostatically driven peristaltic micropump. The proposed micropump consists of a flexible membrane and a single chamber which electrodes are inserted. The single chamber is divided into smaller cells by the electrodes. The fabricated micropump was operated with four electrodes in the membrane and a various phase sequencing actuation. We studied the changes in the flow rate corresponding to the actuating signal applied to the micropump under the zero hydraulic pressure difference between lnlet port and outlet port. The pump was operated from 60 to 130 V. Whereas the maximum flow rate in basic actuating signal is about 83 ${\mu}1/min$ at 15 Hz, the maximum flow rate in optimized actuating signal is about 114 ${\mu}l/min$ at 10 Hz.

Visualization of Internal Flows in the Wall-injected Test Model of a SRM (고체로켓모터 표면분사 시험모델의 유동 가시화)

  • Kim, Do-Hun;Lee, In-Chul;Koo, Ja-Ye;Cho, Yong-Ho;Kang, Moon-Jung;Kim, Yoon-Gon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.31-39
    • /
    • 2011
  • The flowfield in a solid rocket motor was simulated at the wall-injection test model, which has a fin-slot grain and submerged nozzle, and visualized by a smoke-wire. The high speed CCD camera captured the visualized images around the nozzle inlet through the grain center port. The vortical tube structure and circumferential flow patterns at the nozzle throat were visualized. The radial momentum transfer caused by the shear-interactions of slot-outlet flow, fin-base flow and grain port flow from upstream worked as the source of these phenomena.

Size and Shape Optimization of the Oil Pump for Fuel Consuming Reduction (엔진 연비 향상을 위한 오일펌프 사이즈/형상 최적화)

  • Jo, Sok-Hyun;Nam, Kyung-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.22-28
    • /
    • 2008
  • Generally block imbedded type oil pump is adopted to make a small engine. In this paper 1D/3D numerical simulations were conducted to reduce energy consumption of the block imbedded type oil pump. At each stage of engine development we have estimated the oil flow rate and pressure to optimize oil pump sizes by using the 1D system analysis and then accomplished 3D CFD(Computational Fluid Dynamics) simulations to optimize oil pump shapes including inlet/outlet port. As a result, the energy consumption of oil pump has been reduced to nearly 27% and the engine fuel consumption to $1{\sim}1.5%$.

Visualization of rotational flow using SPIV in cylindrical tank (Stereoscopic PIV 속도장 측정기법을 이용한 원통내의 회전 유동장 측정)

  • Choi Jong Ha;Yang Kun Su;Gowda B. H. L.;Sohn Chang Hyun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.44-47
    • /
    • 2004
  • Vortexing might occur during draining from tanks which reduces the rate of outflow. This phenomenon has practical relevance in the fuel feed system in space vehicles and rockets. Due to environmental disturbances rotational motion can be generated in the liquid-propellant tank, which in turn can affect the rate of outflow to the engines. The phenomenon is initialized by rotating the fluid In the experimental tank. The dip quickly develops into a vortex with an air core, which extends to the bottom port, reducing the effective cross-sectional area of the drain outlet and consequently the flow rate. Flow characteristics are investigated using SPIV(Stereoscopic Particle Image Velocimetry) method.

  • PDF

Fabrication and Drive Test of a Peristaltic Thermopnumatic PDMS Micropump

  • Jeong Ok Chan;Park Sin Wook;Yang Sang Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.649-654
    • /
    • 2005
  • This paper presents fabrication and drive test of a peristaltic PDMS micropump actuated by the thermopneumatic force. The micropump consists of the three peristaltic-type actuator chambers with microheaters on the glass substrate and a microchannel connecting the chambers and the inlet/outlet port. The micropump is fabricated by the spin-coating process, the two-step curing process, the JSR (negative PR) molding process, and etc. The diameter and the thickness of the actuator diaphragm are 2.5 mm and $30{\mu}m$, respectively. The meniscus motion in the capillary tube is observed with a video camera and the flow rate of the micro pump is calculated through the frame analysis of the recorded video data. The maximum flow rate of the micropump is about $0.36\;{\mu}L/sec$ at 2 Hz for the zero hydraulic pressure difference when the 3-phase input voltage is 20 V.