액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

태양열 이용 소용량 제습냉방시스템 (Small-Capacity Solar Cooling System by Desiccant Cooling Technology)

  • 이대영;권치호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.154-156
    • /
    • 2008
  • A prototype of the desiccant cooling system with a regenerative evaporative cooler was built and tested for the performance evaluation. The regenerative evaporative cooler is to cool a stream of air using evaporative cooling effect without an inc6rease in the humidity ratio. It is comprised of multiple pairs of dry and wet channels and the evaporation water is supplied only to the wet channels. By redirecting a portion of the air flown out of the dry channel into the wet channel, the air can be cooled down to a temperature lower than its inlet wet-bulb temperature at the outlet end of the dry channels. Incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in the desiccant rotor that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners. At the ARI condition with the regeneration temperature of $60^{\circ}C$, the prototype showed the cooling capacity of 4.4 kW and COP of 0.75.

  • PDF

무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사 (Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • 한국축산시설환경학회지
    • /
    • 제10권1호
    • /
    • pp.23-28
    • /
    • 2004
  • 본 연구는 국내의 있는 무창 분만ㆍ자돈사에 대하여 환기시스템 정립의 기초자료를 수집하고자 수행하였다. 측벽상단입기 지붕굴뚝배기, 천공천장입기 지붕굴뚝배기, 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기의 4종류 무창분만ㆍ자돈사 환기 형태에 대하여 조사하였다. 겨울철 돈사 내 온도, 습도, 공기유속, 암모니아가스 농도의 환경상태를 조사하였다. 겨울철 각 환기 형태별 돈사 내 온도는 환기형태에 따른 온도의 차이는 없었다. 공기유속은 측벽덕트입기 측벽배기가 다른 환기 형태보다 높은 공기 유속이 있었다. 돈사 공간내 각 환기형태별 공기유동은 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기 환기형태가 비교적 다른 환기 시스템에 비교하여 원활한 공기유동이 있는 것으로 나타났다. 암모니아(NH$_3$) 농도도 다른 환기형태보다 측벽덕트입기 측벽배기가 낮은 경향을 보였다. 따라서, 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기가 국내의 무창 분만ㆍ자돈사 환기방식에 적용할 수 있을 것으로 판단되었다.

  • PDF

틸팅열차 주변압기 냉각시스템의 온도설정알고리즘 (Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer)

  • 한도영;노희전;원재영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

대용량 청정 공기 가열 장치 설계 (Design of Large Capacity Clean Air Heater)

  • 김정우;정광수;전민준;이규준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.115-118
    • /
    • 2010
  • 공기 가열 장치는 크게 연소식과 열교환식 2가지가 있으며, 본 논문은 공기를 오염시키지 않은 열교환 방식인 청정 공기 가열 장치의 설계 방법을 기술하였다. 가열 장치는 크게 연소기 (Burner), 가열로 (Furnace), 열교환기 (Heat Exchanger), 배기구로 구성되어 되며, 가열되는 공기 유량과 입/출구 온도값으로부터 가열원인 연소기의 열용량과 연소기 연료인 LNG의 소요량을 구한다. 열교환기 내부에서 연소기의 뜨거운 연소가스와 가열되는 차가운 공기간의 열매체를 통한 간접 열교환이 이루어지므로, 가열되는 공기의 입/출구 온도에서 열교환기의 용량, 크기, 작동 최대 온도를 얻을 수 있게 된다.

  • PDF

온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과 (Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse)

  • 백이;전종길;윤남규;강금춘;이시영
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

자갈축열 태양열 온실의 공기유동 및 축열 성능 (Air Flow and Heat Storage Performance of Solar-Heated Greenhouse with Rock Bed Storage)

  • 이석건;이종원;이현우
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.275-280
    • /
    • 2001
  • The purpose of this study was to investigate the air flow characteristics of the rock bed storage for solar-heated greenhouse design. Heat storage material was gravels and experiments were performed under constant inside temperature condition. The experimental parameters were operation method and air flow rate of fan. It was resulted that the temperature and amount of heat stored in rock-bed increased as the increase of air flow velocity and were more influenced by operation of inlet fan than outlet fan.

  • PDF

환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구 (Performance Characteristics on Environment Change of A/C applied Fin-tube and PF Heat Exchangers)

  • 박경만;엄유식;권영철;이상재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1267-1271
    • /
    • 2009
  • In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.

  • PDF

MIT PEBBLE BED REACTOR PROJECT

  • Kadak, Andrew C.
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.95-102
    • /
    • 2007
  • The conceptual design of the MIT modular pebble bed reactor is described. This reactor plant is a 250 Mwth, 120 Mwe indirect cycle plant that is designed to be deployed in the near term using demonstrated helium system components. The primary system is a conventional pebble bed reactor with a dynamic central column with an outlet temperature of 900 C providing helium to an intermediate helium to helium heat exchanger (IHX). The outlet of the IHX is input to a three shaft horizontal Brayton Cycle power conversion system. The design constraint used in sizing the plant is based on a factory modularity principle which allows the plant to be assembled 'Lego' style instead of constructed piece by piece. This principle employs space frames which contain the power conversion system that permits the Lego-like modules to be shipped by truck or train to sites. This paper also describes the research that has been conducted at MIT since 1998 on fuel modeling, silver leakage from coated fuel particles, dynamic simulation, MCNP reactor physics modeling and air ingress analysis.

벤튜리관 형상에 따른 배기가스 재순환 유동 특성에 관한 연구 (A Study on the Flow Characteristics of the Flue Gas Recirculation with the Change of Venturi Tube Shape)

  • 하지수;심성훈;김대연
    • 한국가스학회지
    • /
    • 제23권1호
    • /
    • pp.12-18
    • /
    • 2019
  • 자동차 엔진이나 소각로 등의 연소기기에서 질소산화물을 저감하기 위한 여러 가지 방법 중에 배기가스 재순환 방법이 널리 쓰이고 있다. 본 연구에서는 고온의 배기가스를 재순환 유입하기 위해 벤튜리 튜브를 사용할 경우에 상온의 공기 노즐 출구 위치를 변화하여 고온의 배기가스를 재순환 유입하는 최적 위치를 도출하기 위해 전산 열유체해석을 통해 살펴보았다. 또한 상온의 공기 노즐 출구에 원뿔을 설치한 경우에 대한 배기가스 재순환 유입량 특성을 고찰하였다. 공기 노즐 출구 위치를 배기가스 재순환 유입 출구의 시작위치(z=0)에서 끝 위치(z=0.6m)로 변화하였을 때 유선과 온도 분포 변화를 관찰하였으며 배기가스 재순환 유입량비와 혼합가스 출구의 평균온도로 정량적으로 비교하였다. 본 연구를 통하여 상온의 공기 노즐 출구 위치는 z=0.15m(1/4L)에서 재순환 유입량과 출구에서의 평균온도가 가장 최대가 되는 것을 알 수 있었다. 또한 공기 노즐 출구에 원뿔을 설치하면 공기 노즐 출구의 속도가 증가하여 배기가스 재순환 유입량이 약 2배 증가하고 혼합가스 출구 온도도 $116^{\circ}C$ 증가하는 것을 알 수 있었다.