• Title/Summary/Keyword: Outgassing.

Search Result 77, Processing Time 0.025 seconds

Vacuum Test of Cavity with Liquid Nitrogen

  • Choi, Suk;Park, Gunn-Tae;Kim, Heetae
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.132-135
    • /
    • 2015
  • Schematic of RAON vacuum system is introduced. Vacuum test for superconducting cavity with liquid nitrogen is performed. Schematic plan for RAON vacuum system is introduced and vacuum control system for superconducting cavity test is constructed. Vacuum pressure of cavity is shown as a function of pumping time. The temperature of cavity is shown as a function of cooling time. Outgassing species from cavity is also detected. Detailed experimental procedure is presented to test the cavity vacuum with liquid nitrogen.

Ultrahigh Vacuum Technologies Developed for a Large Aluminum Accelerator Vacuum System

  • Hsiung, G.Y.;Chang, C.C.;Yang, Y.C.;Chang, C.H.;Hsueh, H.P.;Hsu, S.N.;Chen, J.R.
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.309-316
    • /
    • 2014
  • A large particle accelerator requires an ultrahigh vacuum (UHV) system of average pressure under $1{\times}10^{-7}$ Pa for mitigating the impact of beam scattering from the residual gas molecules. The surface inside the beam ducts should be controlled with an extremely low thermal outgassing rate under $1{\times}10^{-9}Pa{\cdot}m^3/(s{\cdot}m^2)$ for the sake of the insufficient pumping speed. To fulfil the requirements, the aluminum alloys were adopted as the materials of the beam ducts for large accelerator that thanks to the good features of higher thermal conductivity, non-radioactivity, non-magnetism, precise machining capability, et al. To put the aluminum into the large accelerator vacuum systems, several key technologies have been developed will be introduced. The concepts contain the precise computer numerical control (CNC) machining process for the large aluminum ducts and parts in pure alcohol and in an oil-free environment, surface cleaning with ozonized water, stringent welding process control manually or automatically to form a large sector of aluminum ducts, ex-situ baking process to reach UHV and sealed for transportation and installation, UHV pumping with the sputtering ion pumps and the non-evaporable getters (NEG), et al. The developed UHV technologies have been applied to the 3 GeV Taiwan Photon Source (TPS) and revealed good results as the expectation. The problems of leakage encountered during the assembling were most associated with the vacuum baking which result in the consequent trouble shootings and more times of baking. Then the installation of the well-sealed UHV systems is recommended.

Measurement of CTE Change in a Composite Laminate with Aging under Space Environment using Fiber Optic Sensors (광섬유센서를 이용한 우주환경하에서 복합재료 적층시편의 노화에 따른 열팽창계수변화 측정)

  • Gang,Sang-Guk;Gang,Dong-Hun;Kim,Cheon-Gon;Hong,Chang-Seon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.21-26
    • /
    • 2003
  • In this research, the change of coefficient of thermal expansion (CTE) of graphite/epoxy composite laminate under space environment was measured using fiber optic sensors. Two fiber Bragg grating (FBG) sensors have been adopted for the simultaneous measurement of thermal strain and temperature. Low Earth Orbit (LEO) conditions with high vacuum, ultraviolet and thermal cycling environments were simulated in a thermal vacuum chamber. As a pre-test, a FBG temperature sensor was calibrated and a FBG strain sensor was verified through the comparison with the electric strain gauge (ESG) attached on an aluminun specimen at high and low temperature respectively. The change of the CTE in a composite laminate exposed to space environment was measured for intervals of aging cycles in real time. As a whole, there was no abrupt change of the CTE after 1000 aging cycles. After aging, however, the CTE decreased a Little all over the test temperature range. These changes are caused by outgassing, moisture desorption, matrix cracking etc.

A Study on the PZT Application for Spacecraft Components under Space Environment (우주환경하의 위성부품용 압전진동자 활용에 관한 연구)

  • Lee, Sang-Hoon;Moon, Guee-Won;Yoo, Seong-Yeon
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.287-294
    • /
    • 2012
  • In the high vacuum condition of the space, outgassing from any assembly of satellite can contaminate satellites, especially second surface mirror and optical lens, it cause satellite to fail in own missions. Therefore, all unit shall be check for compatibility with vacuum using CVCM (Collected Volatile Condensable Material) and TML (Total Mass Loss) in advance. CVCM and TML of the PZT-5 piezoelectric ceramic vibrator has less than 0.1% and 1.0% respectively. Also, it has less than 500 $ng/cm^2/hr$ of Thermoelectric Quartz Crystal Microbalance for vacuum bake-out test using high temperature(more than $80^{\circ}C$) and high vacuum (less than $5.0{\times}10^{-3}$ Pa). Thus, piezoelectric ceramic vibrator may be employed in the vacuum environments. Finally, it can be confirmed that the characteristics change of the piezoelectric ceramic vibrator is less than 1% under vacuum environments.

Chemorheological Behavior of Cyanate Ester Resin and Properties of Carbon Fiber Reinforced Polymer Composites (시아네이트 에스터 수지의 화학유변학적 거동 및 탄소섬유강화 고분자 복합재료의 물성)

  • Na, Hyo Yeol;Yoon, Byung Chul;Kim, Seung Hwan;Lee, Seong Jae
    • Elastomers and Composites
    • /
    • v.48 no.2
    • /
    • pp.133-140
    • /
    • 2013
  • Carbon fiber reinforced polymer (CFRP) composites consist of carbon fibers in a polymer matrix. Recently, CFRP composites having high thermal stability and low outgassing are finding their use in high performance materials for aerospace and electronics applications under high temperature and high vacuum conditions. Cyanate ester resin is one of the most suitable matrix resins for this purpose. In this study, proper combination of cyanate ester and catalyst, curing behavior, and cure cycle were determined by chemorheology. Optimum condition was found to be catalyst content of 100 ppm and curing temperature of $150^{\circ}C$. Thermal stability and outgassing of cured resin composition were analyzed and the results showed thermal decomposition temperature of $385^{\circ}C$ and total mass loss of 0.29%. The CFRP prepregs and subsequent composites were fabricated by predetermined resin composition and the cure condition. Tensile moduli of the composites were compared with theoretical models and the results were very consistent.

A study on Panel manufacture and Packaging method of FED (FED의 패널제작과 패키징 방법에 관한 연구)

  • Kim, Soo-Yong;Je, Suk-Kun;Park, Dong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.717-722
    • /
    • 2008
  • FED는 잠재적인 평판기술에 따라 현재 탐구를 하였다. 이 프로젝트의 제안은 FED 핵심적인 개발을 위한 진공 패키징 기술 등에 관한 연구 결과를 기술을 보여준다. FED 진공패키징을 위해서는 유리/유리 접합, 진공배기, 게터기술, 그리고 시뮬레이션, 진공중패키징 기술 등을 연구하였다. 유리/유리 접합은 frit glass를 사용하므로 형태에 따르고, 내부압력은 $2{\times}10^{-5}Tott$이며 패널로서 완성을 보여준다. 게터의 결과에 따라 그것은 압력의 증가는 박막 게터에 의해 outgassing이 줄어드는 것을 보여 주었다.

  • PDF

Corrosion of Silver by Outgassing from Rubber

  • Sakai, Jun'ichi;Omoda, Masataka;Ishikawa, Yuichi
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.130-133
    • /
    • 2008
  • Corrosion of silver by outgassed sulfur species from rubber has been investigated by means of quartz crystal microbalance technique (QCM) and cathodic reduction technique. Silver specimens were placed together with a rubber of predefined quantity in an enclosed environment. Corrosion progressed linearly with time and silver sulfide was found as the corrosion product during all the tests. No significant dependence on RH was observed, while the corrosion rate increased as temperature rose. Furthermore the corrosion rate increased logarithmically with the quantity of the rubber placed in the exposure environment. It may be suggested that the corrosion rate of silver is determined by the amount of outgassed sulfur species which is a function of temperature and the quantity of rubber contained in the exposure environment.

A study on Applicability of VacCAD Simulator

  • Kim, Hyung-Taek;Kim, Kang-Won
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.200-206
    • /
    • 2019
  • In this study, we compared the VacCAD and VacSim(Multi), commercial vacuum simulators, to verify the advantages of VacCAD's efficiency. It was emphasized on immediacy and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and vacuum materials. First, usability of simulation mechanism was estimated through the modeling schematics and obtained simulation results of each employed simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping characteristics of commercially available high vacuum systems. In addition, the degree of tolerances on VacCAD was also investigated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacSim(Multi) has been presented, and it was expected that the utilization of VacCAD in vacuum applications to be increased.

잔류가스분석기를 활용한 베이크아웃 시험 종료조건 수립 검토 결과

  • Park, Seong-Uk;Seo, Hui-Jun;Jo, Hyeok-Jin;Im, Seong-Jin;Son, Eun-Hye;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.103.1-103.1
    • /
    • 2015
  • 위성체 개발에 있어서 지상에서 위성체의 부품에 대한 고온($85^{\circ}C$ 이상)과 고진공($5.0{\times}10-3Pa$ 이하)의 상태를 모사하여 오염물질을 제거하는 베이크아웃 시험이 필수적이다. 일반적으로 베이크아웃 시험의 종료여부는 TQCM (Thermoelectric Quartz Crystal Microbalance)을 이용한 탈기체(outgassing)의 흡착률을 측정하여 결정한다. 측정된 흡착률을 통해 시험 대상 표면에서 발생하는 탈기체량을 추정할 수 있으며, 결국 시험 대상의 우주 부품으로써의 적합성을 판단할 수 있다. TQCM을 적용하지 못하는 경우, 베이크아웃 시험 종료여부를 판단하기 위해 잔류가스분석기(Residual Gas Analyzer: RGA)를 활용하는 것을 고려하였다. 베이크아웃 시험 중 잔류가스분석기를 활용하여 시편에서 방출되는 오염물질을 측정하였으며, 그 중 측정량이 가장 많은 40-45 amu 범위의 측정값 추이를 관찰하여, 베이크아웃 시험 종료조건 수립 가능성을 검토하였다.

  • PDF

Development of High-definition PDP(Plasma Display Panel) Barrier Ribs Using Watersoluble UV-curing Resin (수용성 UV경화성 수지를 이용한 고품질 PDP용 격벽제작 기술 개발)

  • Nam, Su-Yong;Woo, Jin-Ho;Lee, Mi-Young;Lee, Gab-Hee;Kim, Goang-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2003
  • Barrier ribs for PDP(plasma display panel) are commonly utilized to have uniform height and width and to prevent opical crosstalk between adjacent cells. The requirements for such barrier ribs are uniform height and shape, low outgassing rate and low porosity, high aspect ratio, and fine resolution. In this study, we are studied about that to make efficiency of material and high quality barrier ribs for PDP. As a result, could got high barrier ribs of $140{\mu}m$ evenly in 1th phenomenon using watersoluble UV curing resin and know that flatness of upper part is also very good.

  • PDF